The development of warm-gas cleanup (WGCU) systems for synthesis gas (syngas) cleanup in in- tegrated gasification combined cycle (IGCC) power plants has the potential to lower the costs of generating power. WGCU includes the removal of mercury (Hg), present in coal, from the syngas. Carbon-based sorbents used for Hg removal are not suitable for high-temperature Hg removal in conjunction with the WGCU. The US Department of Energy’s National Energy Technology Laboratory’s (DOE/NETL) Office of Research & Development (ORD) has been developing various sorbent alternatives to address the problem of high-temperature Hg removal. This study presents analysis of the capture of Hg from syngas streams as a polishing step to attain US Environmental Protection Agency (EPA) Mercury and Air Toxics Standards (MATS) requirements for Hg (0.003 lb/GWhgross for new IGCC plants) using palladium (Pd) adsorbent being tested by DOE/NETL in association with Johnson Matthey (JM). For the present study, it was assumed that syngas is already cleaned to 5 parts per billion by weight (ppbw) Hg, and the Pd sorbent technology is used as a polishing step to achieve the EPA MATS requirements (0.003 lb/GWhgross, equivalent to 2 ppbw given representative process configuration and material flows). The incremental cost of Hg polishing and the additional capital cost needed were estimated for several scenarios/cases. These cases were differentiated by variance in the following parameters, which are important because they have direct im- pacts on additional capital costs ($/kW), and in turn impacts on the levelized cost of electricity (LCOE): 1) Pd cost (varied from $4,000 to $12,000/lb Pd); 2) Gas hourly space velocity (SV) (varied from 500 to 13,500 h -1); 3) Pd loading (varied between 2 w/w% Pd and 5 w/w% Pd); 4) Sorbent make-up rate (varied between 3%, 1%). The ranges were chosen in order to reasonably reflect, in the cases that are analyzed, the actual fluctuations that have been observed in past *Corresponding author. experience in these important parameters that affect cost (e.g., the Pd cost has kept to within the $4 to 12 k/lb range in recent years). In the case of SV, the high and low points of the range are extremes beyond which costs would either be unreasonable, or increase in cost benefit would be negligible. For a typical case (i.e., using mid-range values of the parameters, including SV of 8000 h - 1, 2% Pd loading, 3% make-up rate, $9500/lb Pd cost), the increase in LCOE due to the Pd-polishing system is approximately 0.4% and the additional capital cost is ~$10/kW. As a comparison, the incremental capital cost of conventional Hg removal in an IGCC plant is ~$4 to 8/kW, and the increase in the LCOE is less than 0.4%. Results indicate that in the range of SVs from 3500 h - 1 to 10,000 h - 1, the Hg-polishing step is expected to function adequately and with increase of LCOE limited to about 1% - 2%. The use of a Pd sorbent-based polishing system to reduce trace Hg levels to the EPA MATS requirements for new IGCC power generation appears to be feasible and reasonably cost-effective.
Gasification is used to convert a solid feedstock (coal, petcoke, biomass, etc.) into a gaseous form (synthesis gas [syngas]), which is primarily hydrogen and carbon monoxide (CO). At this point, potential pollutants can be captured and reduced to essentially any desired level and then converted to useful byproducts or disposed of safely. The clean syngas, consisting mainly of CO and hydrogen, can be fired in a gas-turbine/steam-turbine ge- nerator set to produce electricity. In addition to efficiently producing electric power, a wide range of highly va- lued transportation fuels and chemicals can be co-produced from the cleaned syngas, thereby providing the flexibility needed to capitalize on the changing economic market. As a result, gasification provides a flexible technology option for using domestically available resources while meeting any future environmental emission standards.
Gasification is an important strategy for increasing the utilization of abundant domestic US coal reserves. However, the increased use of coal gasification for energy generation, such as in integrated gasification com- bined cycle (IGCC) power plants, or for other purposes, requires responsible cleanup of contaminants resulting from the gasification process.
Recently, stringent regulations have been enacted for trace contaminant emissions from IGCC systems. Spe- cifically, the US Environmental Protection Agency’s (EPA) December 21, 2011, Mercury and Air Toxics Stan- dards (MATS), the first national standards for mercury (Hg) pollution from power plants, require existing power plants to reduce Hg pollution by 90%, reduce acidic gases (hydrogen chloride [HCl] and hydrogen fluoride [HF]) by 88%, and substantially reduce other pollutants by 2015 [
Capture of trace metal/toxic contaminants (Hg, arsenic [As], selenium [Se], cadmium [Cd], antimony [Sb], and phosphorus [P]) found in coal-derived syngas is optimal at lower temperatures; many sorbents have been demonstrated for near-ambient temperature removal of Hg from natural gas and syngas and for removal of Hg from flue gas at temperatures up to 350˚F [
Unfortunately, the limitations of current sorption technologies based on activated carbons are at odds with ef- forts to develop and implement high-temperature, or WGCU of syngas, which would boost the thermal effi- ciency of IGCC plants. WGCU would have the additional benefits of removing toxic contaminants from warm syngas nearer the gasifier exit, helping to eliminate the circulation of dirty water and treatment systems down- stream in IGCC plants; reducing the footprint, cost, and complexity of the systems; and ensuring the disposition of trace metal pollutants so that they will not contaminate process equipment, poison raw materials, or foul cat- alysts or fuel cells [
Drawing on previous experience with sorbents in coal combustion flue gas, the National Energy Technology Laboratory (NETL) has selected potential high-temperature candidate sorbents, developed a process for testing the various candidate sorbents at bench-scale in simulated WGCU, and determined the capacities of the sorbents for capture of Hg, As, Se, and P. Palladium (Pd)-based sorbents are currently among the most promising candi- dates, as they have been found to effectively capture trace contaminants such as Hg, As, Se, and P from syngas at elevated temperatures (400˚F to 700˚F) [
This paper presents the results of a study to estimate the cost of a trace Hg-removal system using Pd sorbents in the context of an IGCC power plant. In cost and performance baselines for bituminous coal-fueled IGCC plants [
· Eliminating scrubbing and quench cooling.
· Replacing Selexol with the RTI high-temperature sulfur removal and recovery technology.
· Replacing conventional low-temperature Hg removal with a high-temperature Hg removal technology.
· Adding incidental chloride removal, SCR for control of the increased nitrogen oxide (NOX) emissions due to increased ammonia passing through the gas cleanup train, and other design features to accommodate process impacts.
The feasibility of a proprietary WGCU technology developed by RTI and impacts on the cost of electricity (COE) have been previously assessed [
new EPAMATS requirements for Hg (new IGCCs: 0.003 lb Hg/GWh gross power generation).
A possible solution for the Hg-polishing step uses Pd sorbents in a fixed bed. NETL and JM have developed alumina-supported Pd sorbents that enable high-temperature (>260˚C) Hg removal. Based on preliminary bench- scale and syngas slipstream testing at Southern Company’s pilot facility, this sorbent has the capability to per- form the required Hg polishing [
The approach taken in this study has been to develop a simplified model of the Pd sorbent-based Hg-removal system, modify the IGCC baseline process including the RTI WGCU to integrate the Hg-removal system, and perform cost calculations to determine the incremental capital and operating costs impacting the COE.
In the context of an IGCC plant, the Hg-polishing system would be added directly following the bulk Hg re- moval in the WGCU step. The overall process diagram of the baseline IGCC plant, including the RTI WGCU and sulfur-recovery systems followed by the Hg-polishing system, is as depicted in
DOE/NETL has previously investigated the use of the JM Pd sorbents to remove Hg from coal gasification syngas. Detailed calculation procedures for determining extent of Hg removal using the Pd sorbents have been defined, accompanied by economic analysis to quantify costs of the Hg removal. The calculations assume a typi- cal process arrangement for the sorbent-based Hg-removal system; this is depicted in
As expected, there are considerable differences in gas flow rates, Hg concentrations and key operating condi- tions (pressure) between the current application (Hg polishing using Pd sorbents), and previous analysis that considered bulk-removal of Hg using the RTI WGCU technology. In this study, a new set of assumptions about parameters governing the performance of the Pd sorbent unit in the IGCC plant context was developed for the concept of Hg polishing to low levels. In this context, analysis of how the levelized cost of electricity (LCOE) is affected by the Pd cost, Pd loading in the sorbent, gas hourly space velocity (SV), and sorbent make-up rates has been performed. Given the substantial changes in equipment sizes, rates, and fluctuations in Pd value in recent years, equipment and other capital costs (adsorber pressure vessels constitute an important capital cost element in addition to the sorbent cost) were also updated. The impact of steam consumption, electric loads, and pressure drop due to the Pd sorbent system on power plant performance was quantitatively accounted.
The most significant parameters affecting the cost of Hg capture are the cost of the Pd sorbent, the amount of sorbent in the bed (inversely proportional to the SV), sorbent make-up rate, and the quantity of Pd in the sorbent. Published RTI/Nexant analysis was used as a basis for LCOE calculations2. Various cases were devised, sum- marized in
The base case was designed having mid-range values of the parameters, and which is expected to represent a reasonable, typical case. This case assumes 2% w/w Pd/alumina sorbent, with an SV of 8000 h−1, Pd cost of $9500/lb (~$651/troy ounce [trz]), and a sorbent make-up rate of 3%. SVs of 500 to 13,500 h−1 were chosen be- cause preliminary studies revealed that the adsorber volume and cost would increase significantly below 500 h−1. Little change in adsorber volume was observed with SVs in excess of 15,000 h−1. Palladium sorbent costs were approximated to be those of the pure metal. Pure Pd costs spanning a time period of three-plus years (2010
Pd Sorbent Loading, w/w%3 | Pd Price, $/lb | Space Velocity, h−1 | Make-Up Rate, wt% Bed | |
---|---|---|---|---|
Case 1a | 2 | 9500 | 500 to 13,500 | 3 |
Case 1b | 2 | 4000 to 12,000 | 8000 | 3 |
Case 2a | 2 | 9500 | 500 to 13,500 | 1 |
Case 2b | 2 | 4000 to 12,000 | 8000 | 1 |
Case 3a | 5 | 9500 | 500 to 13,500 | 3 |
Case 3b | 5 | 4000 to 12,000 | 8000 | 3 |
Case 4a | 5 | 9500 | 500 to 13,500 | 1 |
Case 4b | 5 | 4000 to 12,000 | 8000 | 1 |
to 2013) were used to obtain the range of variation for Pd cost. Recent pilot plant tests at Southern Company used a 2 w/w% Pd sorbent with an SV of 1704 h−1; accordingly, 2% and 5% Pd sorbents were used. Bed make- up rates were varied from 3 to 1% of the bed weight. Previous NETL experience indicates that 40% Hg content (wt Hg/wt Pd) at 40% breakthrough is a reasonable assumption. The adsorber beds were sized to be 10 feet in diameter for reasonable superficial gas velocities and pressure drops lower than 4%.
The RTI WGCU process was assumed to remove Hg to 5 ppbw in the clean syngas to the turbine. The EPA MATS requirement for Hg emissions is 0.003 lb/GWh gross power output (2 ppbw). For the Nexant RTI Case 4 chosen as the power plant for this study, the gross power output is ~766 MW. Accordingly, the Hg emissions without a polishing step would be 6.93 × 10−3 lb/GWh. Therefore, the extent of Hg removal needed to meet EPA MATS is ~57%. This implies that the Hg breakthrough in the beds would be approximately 40% (~60% cap- ture).
A model of the Pd sorbent process was developed to account for the new operating conditions and parameters. It is restricted to cases with only Hg adsorption (i.e., no co-adsorption of As, Se, and P is considered). The capital and operating & maintenance (O & M) costs of capturing Hg are estimated using bed residence time, Pd price, Pd sorbent weight%, Hg content at breakthrough, and make-up rate as primary input parameters in the spread- sheet. Process simulations for the IGCC plant indicated that the exhaust gas composition and conditions follow- ing the combustion turbine are independent of the extent of water-gas shift (WGS) reaction occurring in the Pd sorbent beds. Because plant performance and cost calculations would not be affected, 0% WGS in the adsorber is assumed.
The cost of the Pd sorbent-based Hg-removal unit is dominated by the cost of the sorbent itself, because it in- corporates a significant quantity of Pd metal with recent spot prices as high as ~$900 (September 2014). How- ever, sorbent fabrication and ongoing refining costs to maintain the sorbent in working order also contribute to capital and O & M costs, respectively, associated with this unit. The amount of Pd initially required for the four sorbent vessels is used to calculate the sorbent cost. This estimate includes ~20% storage/excess sorbent capacity stored onsite.
The volume of gas contacted per unit mass of adsorbent, SV/XPd, where SV is the space velocity and XPd is the weight percentage of Pd in the sorbent, is a primary parameter affecting the cost of Hg capture. Given a specific value for XPd, and assuming no mass transfer limitations, higher SVs lead to lower initial sorbent costs. Mini-
mizing the amount of sorbent requires higher gas velocities through the material and/or shorter gas residence times (higher SVs). In applications where a large volume of syngas volumetric flow with low inlet Hg concen- trations exists, the required amount of sorbent to provide adequate Hg capture capacity might be relatively low. However, this corresponds to very short gas residence times in the sorbent bed (<<1 second) in which mass tran- sfer constraints might not allow sufficient capture of Hg. Increasing residence time by decreasing the cross-sec- tional area of the sorbent beds increases pressure drop in the sorbent beds and the associated energy penalty. Acceptable pressure drop has been assumed to be 4% of the inlet gas pressure. Testing of the Pd sorbent for Hg capture in Southern Company tests provides some guidance on required operating conditions and parameters, with SVs of 1500 to 3700 h−1, and pressures 150 to 200 pounds per square inch gauge (psig) [
Even a small pressure drop attributable to an Hg-polishing sorbent unit could have a negative impact on the overall efficiency of a gas turbine cycle. In the recent baseline IGCC plant Case 1 (as described in the NETL Bituminous Baseline report) [
The Hg-removal system affects plant power output in three main respects: 1) The pressure drop of the syngas through the sorbent vessels for which an energy penalty is taken; 2) The power to operate the regeneration gas circulating blower; and 3) The steam to heat the regeneration gas, which is taken from the main plant steam cycle, causing a decrease in steam turbine output. In order to calculate these accurately, a process model of the IGCC plant was developed in a process simulator, in which syngas flows, steam flows, the gas turbine, steam turbine, and Hg-sorbent unit including the regenerator were modeled to a sufficient extent to determine impacts of the Hg-polishing system on plant net output. The results of the plant simulation in terms of key impacts of the Hg-removal system on plant power are shown in
The energy penalty from the pressure drop through the Hg vessels is by far the most significant impact. It in- creases into the several MW range for lower SV values. The 1000 lb/hr of 538˚C steam withdrawn from the steam cycle causes a loss of approximately100 kW in the gross output of the steam turbine; it is relatively insig- nificant because the total steam flow in the cycle is more than 1,000,000 lb/hr. The power to operate the nitrogen (N2) blower, which provides 2000 lb/hr of N2 at 525˚C for the regeneration cycles, is negligible at about 20 kW.
The increase in the LCOE of the IGCC plant and the incremental capital cost ($/kW) were estimated for all cases, and are shown in
Baseline Plant | Pd Bed, SV = 13,500 h−1 | Pd Bed, SV = 4500 h−1 | Pd Bed, SV = 1500 h−1 | Pd Bed, SV = 500 h−1 | |
---|---|---|---|---|---|
Pressure Drop Penalty, MW | None | 0.21 | 0.63 | 1.94 | 6.28 |
N2 Blower Penalty, MW | None | 0.02 | |||
Steam Turbine Output, MW | 316.7 | 316.6 | |||
Net Plant Power, MW | 641.0 | 640.8 | 640.5 | 639.8 | 637.3 |
As the SV is varied from 500 to 13,500 h−1, keeping the cost of Pd constant at $651/trz with 2% wt Pd sorbent and 3% make-up rate, the percentage increase in LCOE is ~0.3% to 4.3% (
For the base case, the performance of the Hg-polishing sorbent system (~0.4% increase in LCOE, ~$10/kW incremental capital cost for the base case SV = 8000 h−1, $9500/lb Pd, 2 w/w% Pd sorbent, 3% make-up rate) is comparable to that of the carbon-based, low-temperature Hg adsorbers (<0.4% increased LCOE, $4 to $8/kW)5. Therefore, the Hg-polishing system holds significant promise to lower the cost of Hg capture from warm syngas streams.
In this analysis, a number of assumptions, based on experimental results and other studies, were made about Pd sorbent operating characteristics and constraints. To decrease the uncertainty associated with those assumptions, parameters such as Pd cost, SV, sorbent composition, and sorbent make-up rate were varied over possible ranges while observing the effects on performance and costs.
Preliminary results from this study indicate that a Pd sorbent-based polishing system in an IGCC plant with WGCU could be used to reduce trace Hg levels to the new EPA MATS requirements for IGCC power genera- tion in a cost-effective manner. For gas hourly SVs greater than 3500 h−1, COE is elevated less than 2% by addi- tion of the Hg-polishing step. For SVs greater than 10,000 h−1, the COE increase continues to improve margi- nally, but it is likely that Hg mass-transfer limitations may limit the performance of the Pd sorbent system at these higher SVs (high gas velocities and low gas residence times) in the sorbent beds. Accordingly, for a range of SVs from 3500 to 10,000 h−1, the Hg-polishing step is expected to function adequately and with an increase of LCOE limited to approximately 1% to 2%. As a comparison, the incremental capital cost of conventional (95%) Hg removal in an IGCC plant is ~$4 to $8/kW, with less than 0.4% increase in the LCOE [
Cost of the Pd sorbent-based polishing system is strongly affected by the cost of the sorbent, which in turn depends primarily upon the cost of Pd. Large and unpredictable fluctuations in the cost of Pd will necessarily have a corresponding impact on the capital cost of a system, as illustrated by case studies in which the price of Pd was varied. For higher SVs, less sorbent and less Pd are required, though as previously discussed there will be practicable limits on how far this can be taken.
Further testing of the Pd sorbent at actual conditions and trace Hg levels in the IGCC Hg-polishing scenario would be highly desirable to confirm the assumptions and results of this study. In addition to the use of Pd-based sorbent for polishing (i.e., reducing Hg levels from 5 ppbw to 2 ppbw), the sorbent could also be used for bulk Hg
removal from syngas. Finally, the present analysis was restricted to cases assuming only Hg adsorption, so the effects of additional adsorption of As, Se, and P were not explored. Nevertheless, these may have significant impact on Hg adsorption capacity/characteristics, and so future work should extend to consider the overall beha- vior of Pd sorbents for simultaneous removal of Hg and these additional pollutant species.
This article discusses research and development sponsored by an agency of the United States Government. Nei- ther the United States Government nor any agency thereof, nor any of their employees, makes any warranty, ex- press or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trade- mark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.
The authors thank Henry Pennline (NETL) and the staff at Johnson Matthey for their excellent guidance, contributions, and cooperation.
As: Arsenic
Cd: Cadmium
COE: Cost of Electricity
DOE: US Department of Energy
EPA: US Environmental Protection Agency
FR: Federal Register
HCl: Hydrogen Chloride
HF: Hydrogen Fluoride
Hg: Mercury
IGCC: Integrated Gasification Combined Cycle
JM: Johnson Matthey
LCOE: Levelized Cost of Electricity
MATS: Mercury and Air Toxics Standards
N2: Nitrogen
NETL: National Energy Technology Laboratory
NOX: Nitrogen Oxides
O & M: Operation and Maintenance
ORD: Office of Research and Development
P: Phosphorus
Pd: Palladium
ppbw: Parts per Billion by Weight
psia: Pounds per Square Inch Absolute
psig: Pounds per Square Inch Gauge
RTI: RTI International
Sb: Antimony
SCR: Selective Catalytic Reduction
Se: Selenium
SV: Space Velocity
Syngas: Synthesis Gas
Trz: Troy Ounce
WGCU: Warm-Gas Cleanup
WGS: Water-Gas Shift