In the mathematical model of electrostatic sensors established by Yan Yong in previous studies, the thickness of the insulating layer was not taken into account in the model. In order to study the static monit oring of electrostatic sensors in more depth, this paper considers the influence of insulation layer when establishing the mathematical model of the sensor. By establishing a mathematical model, the point charge measurement model was deduced and formulated. By studying the sensitivity of the sensor, it is concluded that the sensor insulation layer must be considered. The thickness of the insulation layer reduces the sensitivity of the sensor, and the relationship between the sensor spatial sensitivity and the grinding particle size distance is obtained. Compared with the models established by the predecessors, it is concluded that the mathematical model constructed in this paper is feasible and reliable. For the future research of electrostatic sensors.
Aero-engine is one of the most important parts of aircraft. Aero-engine condition monitoring is the guarantee of safe and reliable operation of aircraft. In order to meet the new requirements of aero-engine fault prediction technology, it is necessary to develop more advanced engine condition detection technology. The electrostatic detection technology can monitor the abrasive particles produced by the wear of parts in the lubricating oil system on-line and warn the engine early fault. At present, the work to be done is to improve the measurement accuracy of electrostatic detection technology. Due to the late start of domestic electrostatic monitoring technology and imperfect industrial information, there is still a gap between the aero-engine fault detection technology and foreign countries. At present, the technology has been banned from export, in order to improve the level of domestic aero-engine fault monitoring, domestic researchers have done a lot of works.
Aircraft engine lubrication circuit electrostatic monitoring technology is based on the principle of electrostatic induction, to on-line detect the debris generated by engine failure. It monitors engine components deterioration at an early stage to prevent engine failure. On-line monitoring of charged debris, predecessors have done a lot of work. Powrie H.E.G. studied the application of electrostatic sensors in aero engine lubrication circuit [
Gajewski J.B. established a three-electrode electrostatic sensor measurement model. The three-electrode electrostatic system consists of debris charge in the sensing zone, the induced charge on the probe, the charge on the electromagnetic screen. Based on the theory of electromagnetism, detected circuit, the charge of the debris and the relationship between charge density and induced potential in the probe are obtained. Using the dynamic charge density and the standard electrostatic charge density which does not change with time, the induced potential on the probe is calculated and analyzed [
In this paper, the electrostatic sensing model is used as the main research object, and the basic research of the charged abrasive particles in the sensor is carried out. The influence of the insulation layer of the sensor on the abrasive particles monitoring is analyzed, so that the sensor can monitor the abrasive particles more in line with the actual situation and provide a reference for improving the engine fault prediction ability effectively.
When charged particles pass through the effective induction region of the electrostatic sensor, electrons will flow inside the metal probe. In order to balance the external charges nearby, the charge inside the probe will be redistributed and accompanied by the electron flow. In this process, there is no charge exchange between the charged body and the electrostatic sensor, and the same amount of charge will be generated on the probe. Then the electrostatic sensor will generate the induced current and convert it into voltage output in proportion. After processing by the conditioning circuit, it will be output to the acquisition system and display. When the charged particles leave the effective induction region of the sensor, the positive and negative induction charges inside the probe will neutralize, making the probe return to be electrically neutral.
The electrostatic sensor based on the principle of electrostatic induction is shown in
According to the physical model shown above, the electrostatic sensing model of charged abrasive particles is established as shown in the following
| M N | 2 = ( R + r 1 ) 2 + | O M | 2 − 2 ( R + r ) 1 | O M | cos ϕ
Then,
| M N | 2 = ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ
The charge of the abrasive particle is q at point p. According to Coulomb’s law, the electric field intensity E produced at the point N on the metal probe can be obtained.
E = q 4 π ε 0 | P N | 2
Among them, | P N | is the distance from P to N.
| P N | 2 = ( Z − H 2 ) 2 + | M N | 2
where, | M N | has been written out before.
The electric field intensity E of charged abrasive q at metal probe N is decomposed. In the oxy plane, the E is decomposed along the ON direction as EM.
E M = E sin ∠ N P M cos φ
Among them,
sin ∠ N P M = M N P N
φ = ∠ O N M
Therefore, according to the above formula,
E M = E | M N | | P N | cos φ = q 4 π ε 0 | P N | 2 | M N | | P N | cos φ
Then,
E M = q [ ( R + r 1 ) − x cos ϕ ] 4 π ε 0 { ( z − H 2 ) 2 + [ ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 2 } 3 2
According to the Gauss theorem and Coulomb’s law, the total induction charge on the metal probe can be obtained.
Q = ε 0 ( R + r 1 ) ⋅ ∫ − π π ∫ − H 2 H 2 q [ ( R + r 1 ) − x cos ϕ ] 8 π ε 0 { ( z − H 2 ) 2 + [ ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 2 } 3 2 d H d ϕ = ( R + r 1 ) q 4 π ∫ 0 π ( R + r 1 ) − x cos ϕ ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ⋅ { z + H 2 [ ( z + H 2 ) 2 + ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 1 2 − z − H 2 [ ( z − H 2 2 ) + ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 1 2 } d ϕ
In the formula, Q is the induced charge produced by the charged abrasive particles on the metal probe, and R is the radius of the pipe, and q is the charged abrasive particles, x is the X coordinate value of the position of the abrasive particles, and angle ϕ is the angle between NO and OP’. V indicates the speed of charged abrasive particles, H indicates the axial length of the metal probe, and r1 is the thickness of the insulation layer.
The charged metal particles move along the axial direction of the sensor, and their positions change with time. Assuming that the location of metal particles is unchanged at the X axis and its speed is V, z = vt is known. Therefore, the above formula can be rewritten as follows:
Q = ( R + r ) 1 q 4 π ∫ 0 π ( R + r ) 1 − x cos ϕ ( R + r ) 1 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ⋅ { v t + H 2 [ ( v t + H 2 ) 2 + ( R + r ) 1 2 + x 2 − 2 ( R + r ) 1 x cos ϕ ] 1 2 − v t − H 2 [ ( v t − H 2 ) 2 + ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 1 2 } d ϕ
It can be seen from the above formula that the induced charge Q produced on the metal probe is related to the distance X between the charged abrasive particle and the central axis of the pipe, the velocity V of the charged abrasive particle, the charged quantity Q of the charged abrasive particle, the thickness R1 of the insulating layer, and the size of the sensor. Through the numerical calculation and analysis of the above formula, we can consider the relationship between each factor and the amount of induced charge with single factor and multiple factors. Below (
When the charged abrasive particle passes through the xoy plane as the zero point of time T, −0.1 < T < 0 indicates that the charged abrasive particle enters the effective induction region of the sensor and gradually approaches the xoy plane, but does not pass through the xoy plane. 0 < T < 0.1 indicates that the charged abrasive particles have passed through the xoy plane and are gradually away from the xoy plane, but are still in the effective induction range of the electrostatic sensor. T = 0 indicates that the charged metal grains are on the xoy plane. The time t [−0.1, 0] does not mean that the time is negative, but that the charged metal abrasive particles are near or far from the xoy plane of the sensor model. As can be seen from the above diagram, when the charged metal abrasive particles are close to the center of the ring probe (xoy plane), the induced charge on the probe increases sharply, and reaches the maximum value when it reaches the xoy plane. When the charged metal abrasive particles are far from the center of the ring probe (xoy plane), the induced charge on the probe decreases sharply, and with the increase of the distance away from the probe, the induced charge on the probe decreases steadily, at this time the induced charge is very small.
Define the spatial sensitivity, the absolute value of the ratio of the induced charge Q produced by the charged metal abrasive particles passing through the induction region of the sensor to the charged abrasive grain q, that is
S ( x , z ) = | Q q |
It is can be obtained
S ( x , z ) = ( R + r 1 ) 4 π ∫ 0 π ( R + r ) 1 − x cos ϕ ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ⋅ { z + H 2 [ ( z + H 2 ) 2 + ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 1 2 − z − H 2 [ ( z − H 2 ) 2 + ( R + r 1 ) 2 + x 2 − 2 ( R + r 1 ) x cos ϕ ] 1 2 } d
According to the above formula, the sensitivity of the electrostatic sensor can be analyzed. The sensitivity of the electrostatic sensor indicates the accuracy of monitoring abrasive particles, that is, sensitivity is an important index to judge the accuracy of an electrostatic sensor. From the above formula, it can be seen that the sensitivity of the electrostatic sensor is related to the axial length, radial length and insulation thickness of the sensor, and the sensitivity of the sensor is related to the position of the metal abrasive particles.
When the size of the electrostatic sensor is determined, that is, H, r1, R remain unchanged, the sensitivity of the electrostatic sensor is only related to the position of the charged metal abrasive. Select H = 0.02 m, R = 0.01 m, r1 = 0.001 m, z = 0. Simplify the above formula.
S ( x , z = 0 ) = 0.011 4 π ∫ 0 π 0.011 − x cos ϕ ( 0.011 ) 2 + x 2 − 0.022 x cos ϕ ⋅ 0.02 [ 0.0001 + ( 0.011 ) 2 + x 2 − 0.022 x cos ϕ ] 1 2 d ϕ
The following
The relationship between the sensitivity of the electrostatic sensor and the radial position of the charged metal abrasive particles can be clearly seen from the above diagram. When the radial position of the charged metal abrasive particles is zero, that is, on the Z axis of the pipe center, the sensitivity of the electrostatic sensor is the lowest. When the radial distance is 0.01, the sensitivity of the sensor is the highest on the inner surface of the insulation layer. This situation is consistent with the physical characteristics of electrostatic induction.
The sensitivity of the electrostatic sensor without considering the thickness of the insulating layer is S1, and that of the electrostatic sensor with considering the thickness of the insulating layer is S2. The reason for the difference between the two sensitivities is that the thickness of the insulating layer in the sensor is taken into account when establishing the charged abrasive particle model, which is also a factor that must be considered in the design of the electrostatic sensor. As shown in
difference between the two sizes is not significant. It shows that the model established in this paper is reliable and feasible.
1) The mathematical model of the electrostatic sensor is established, and the influence of the insulation layer of the electrostatic sensor is considered. The mathematical model is derived in detail. The sensitivity index of sensor is defined, and the space sensitivity curve of electrostatic sensor is obtained.
2) The sensitivity of the sensor is analyzed, and the relationship between the spatial sensitivity of the sensor and the orientation distance of the grinding particle is obtained. In the center line of the sensor axis, the space sensitivity of the electrostatic sensor is the lowest. Along the pipe radius, the space sensitivity increases gradually to the pipe wall, and the space sensitivity is the highest over the pipe wall.
3) The location of charged abrasive particles and radial radius of the sensor are studied by comparing with the model established by predecessors, and the spatial sensitivity curves are verified by each other. The accuracy and reliability of the mathematical model of the electrostatic sensor are illustrated.
The authors declare no conflicts of interest regarding the publication of this paper.
Wang, J.W. (2018) Research on Point Charge Measurement Model of Electrostatic Sensor. Open Access Library Journal, 5: e4870. https://doi.org/10.4236/oalib.1104870