Objective: To assess perceptions about ease of use and other benefits of Wepox Pen<sup>TM</sup> (loaded with 30,000 IU cartridge of recombinant erythropoietin) in the management of anemia in adult chronic kidney disease (CKD) patients. Material and methods: In this prospective, observational, multicentric post marketing surveillance, adult CKD patients treated with erythropoietin were enrolled from November 2015 to December 2016 to understand their opinions about Wepox Pen<sup>TM</sup>. Ease of use of pen, ease of administering accurate dose, confidence in administration and ease of storage and disposal of cartridge were assessed on five points Likert scale: 1. very easy; 2. somewhat easy; 3. neither easy nor difficult; 4. somewhat difficult; 5. very difficult. Global assessment was performed on five points scale: 1. excellent; 2. very good; 3. good; 4. average; 5. not good. Safety was recorded by checking pain and discomfort and adverse events. Results: A total of 263 patients (mean age 32.87 years; 66% male; 34% female) were enrolled. Number of patients reporting ease of use as “very easy” from 209 (80.7%) at baseline increased to 245 (94.6%) and 249 (96.1%) at visit 2 (p = 0.001) and visit 3 (p = 0.001) respectively. Number of “very easy” response for accurate dose increased from 236 (91.1%) at visit 1 to 246 (95%) at visit 2 (p = 0.84) and 249 (96.1%) at visit 3 (p = 0.001). Number of the patients with “no pain” at injection site increased from 177 (68.3%) at visit 1 to 205 (79.2%) and 212 (81.9%) at visit 2 (p = 0.001) and visit 3 (p = 0.001) respectively. Improvement in number of patients with “no hurt” at visit 2 (p = 0.538) and visit 3 (p = 0.286) was not statistically significant. Number of patients reporting “somewhat easy” to “very easy” confidence in self injection increased from 251 (96.9%) at visit 2 to 255 (98.5%) at visit 3. Number of patients reporting ease of storage and disposal of cartridge as “somewhat easy” to “very easy” increased from 254 (98.1%) at visit 2 to 256 (98.9%) at visit 3. According to the global assessment, 144 (56.3%) cases reported “excellent” response. “Very good” and “Good” responses were reported by 106 (41.4%) and 6 (2.3%) patients respectively. A total of 230 (98.7%) patients said that they would prefer to use erythropoietin pen device for further treatment too. Conclusion: Wepox Pen TM(recombinant erythropoietin) is easy to use and does not cause significant pain or discomfort. Ability to self-administer recombinant erythropoietin with Wepox Pen TM is a great advantage which can make a significant difference for both CKD patients and doctors. Storage and disposal of cartridge is also easy.
Chronic kidney disease (CKD) is one of the significant clinical problems worldwide and more so in India, because of the high prevalence of diabetes, a known risk factor. According to the SEEK (Screening and Early Evaluation of Kidney Disease) study, the prevalence of CKD in India is 17.2% [
Effective therapy of anemia can reduce requirement of blood transfusion and improve quality of life and survival [
The objective of this study was to assess perception about ease of use and other benefits of Wepox PenTM (loaded with 30,000 IU cartridge of recombinant erythropoietin) in the management of anemia in adult CKD patients.
In this open label, observational and multi-centric post marketing surveillance (PMS), adult patients between 18 - 65 years of age with anemia due to stage 3 - 5 CKD and treated with erythropoietin were enrolled from November 2015 to December 2016 with convenience sampling method. In addition to pregnant and lactating women, patients with other medical conditions that can affect participation in the survey were excluded from the study based on the judgment of the investigator. Each enrolled patient was provided Wepox PenTM with 30,000 IU, three milliliter cartridge of recombinant erythropoietin. The pen device was provided free of cost but the cartridges expense was borne by the patients. Patients were instructed to use Wepox PenTM as per their dosage requirement or according to physician’s discretion for four months. Patients were evaluated at three visits. Second and third evaluation was done at day 61 ± 3 and day 122 ± 3. During all visits patients were asked to fill a questionnaire which included questions related to ease of use of Wepox PenTM, pain at injection site and ease of accuracy of dose. At visits 2 and 3, in addition to these parameters, patients were also asked to rate their confidence in administration, ease of storage and disposal of cartridge. Patients were asked to complete global assessment for Wepox PenTM use at visit 3. Ease of use of pen, ease of administering accurate dose, confidence in administration and ease of storage and disposal of cartridge was assessed on five point Likert scale; 1-very easy; 2-somewhat easy; 3-neither easy nor difficult; 4-somewhat difficult; 5-very difficult. Global assessment was performed on five point scale-1-excellent; 2-very good; 3-good; 4-average; 5-not good. Assessment of preference was checked by asking a question “Would you prefer using Wepox PenTM for further treatment?” Safety and tolerability was checked by recording discomfort like burning or itching at the site of injection immediately after injection on six point scale-0-no hurt; 1-hurts little bit; 2-hurts little more; 3-hurts even more; 4-hurts whole lot; 5-hurts worst. Additionally, other adverse events, if any were also recorded. Wepox pen is an approved device in India and is standard of care for administration of erythropoietin in patients with anemia in CKD. The study was carried out as a post-marketing surveillance for observing the benefits of the pen device. Hence as per the country norms, ethics committee approval was not required.
Continuous data are presented as mean and standard deviation whereas categorical data are presented as number and percentages. Chi square test was used to analyze difference between three visits.
A total of 263 patients with mean age of 32.87 years and mean duration of CKD of 2.3 years were enrolled in this survey. The survey population consisted of 173 (66%) males and 89 (34%) females (
A total of 30 (11.4%) patients had either diabetes or hypertension. Diabetes and hypertension was present in 14 (6.1%) and 16 (5.3%) patients respectively.
At baseline 209 (80.7%) patients reported the ease of erythropoietin pen device as “very easy”. The number of patients reporting ease of erythropoietin pen device as “very easy” increased to 245 (94.6%) and 249 (96.1%) respectively. The improvement in number of patients reporting ease as “very easy” at visit 2 and visit 3 was statistically significant compared to baseline (
Number of patients reporting taking accurate dose with erythropoietin pen device as “very easy” increased from 236 (91.1%) at visit 1 to 246 (95%) at visit 2 and 249 (96.1%) at visit 3. The improvement in response rate of “very easy” at visit 2 was not significant (p = 0.84); however, at visit 3 the improvement was significant (
At visit 1 177 (68.3%) of the patients had “no pain” at injection site by using Erythropoietin Pen device. The number of patients with “no pain” increased to 205 (79.2%) and 212 (81.9%) at visit 2 and visit 3 respectively. The improvement at visit 2 and visit 3 was statistically significant (
Parameter | Result |
---|---|
Age (years) (n = 263) | |
Mean ± SD | 32.87(+10.46) |
Range | 18 - 48 years |
Gender (n = 262) | |
Male n(%) | 173(66%) |
Female n(%) | 89(34%) |
Number of CKD years (n = 75) | |
Mean (SD) | 2.30(1.75) |
Range | 0.6 - 8 years |
Percentage of patients reporting ease of erythropoietin pen device use | Percentage of patients reporting ease of taking accurate dose | |||||
---|---|---|---|---|---|---|
Visit 1 (N = 259) N(%) | Visit 2 (N = 259) N(%) | Visit 3 (N = 259) N(%) | Visit 1 (N = 259) N(%) | Visit 2 (N = 259) N(%) | Visit 3 (N = 259) N(%) | |
Very easy | 209(80.7%) | 245(94.6%) | 249(96.1%) | 236(91.1%) | 246(95%) | 249(96.1%) |
Somewhat easy | 049(18.9%) | 014(5.4%) | 10(3.9%) | 22(8.5%) | 13(5%) | 10(3.9%) |
Neither easy nor difficult | - | - | - | - | - | - |
Somewhat difficult | 001(0.4%) | - | - | 1(0.4%) | - | - |
Very difficult | - | - | - | - | - | - |
P value (Chi-square test) | 0.001 (Chi-square value 23.104) | 0.001 (Chi-square value 30.160) | 0.84 (Chi-square value 2.985) | 0.001 (Chi-square value 5.469) |
At Visit 1 245 (94.6%) of the patients had “no hurt” with erythropoietin pen device. The number of patients with “no hurt” at visit 2 and visit 3 were 248 (95.8%) and 250 (96.5%) respectively (
The number of patients reporting “somewhat easy” to “very easy” confidence in self injection increased from 251 (96.9%) at visit 2 to 255 (98.5%) at visit 3. Similarly, number of patients reporting ease of storage and disposal of cartridge as “somewhat easy” to “very easy” increased from 254 (98.1%) at visit 2 to 256 (98.9%) at visit 3 (
Visit 1 (N = 259) N(%) | Visit 2 (N = 259) N(%) | Visit 3 (N = 259) N(%) | |
---|---|---|---|
No Pain | 177 (68.3%) | 205 (79.2%) | 212 (81.9%) |
Little pain | 78 (30.2%) | 52 (20.1%) | 46 (17.8%) |
Mild pain | 4 (1.5%) | 2 (0.7%) | 1 (0.3%) |
Moderate pain | - | - | - |
Severe pain | - | - | - |
Worst pain | - | - | - |
P value (Chi square test) | 0.001 (Chi-square value 7.817) | 0.001 (Chi-square value 12.645) |
Visit 1 (N = 259) N(%) | Visit 2 (N = 259) N(%) | Visit 3 (N = 259) N(%) | |
---|---|---|---|
No hurt | 245 (94.6%) | 248 (95.8%) | 250 (96.5%) |
Hurts little bit | 14 (5.4%) | 11 (4.2%) | 9 (3.5%) |
Hurts little more | - | - | - |
Hurts Even more | - | - | - |
Hurts whole lot | - | - | - |
Hurts worst | - | - | - |
P value (Chi square test) | - | 0.538 (Chi-square value 0.378) | 0.286 (Chi-square value 1.137) |
Confidence in self injection | Ease of storage and disposal of cartridge | |||
---|---|---|---|---|
Visit 2 (N = 259) N(%) | Visit 3 (N = 259) N(%) | Visit 2 (N = 259) N(%) | Visit 3 (N = 259) N(%) | |
Very easy | 192 (74.1%) | 219 (84.6%) | 205 (79.2%) | 225 (86.9%) |
Somewhat easy | 59 (22.8%) | 36 (13.9%) | 49 (18.9%) | 31 (12%) |
Neither easy nor difficult | 8 (3.1%) | 4 (1.5%) | 5 (1.9%) | 3 (1.1%) |
Somewhat difficult | - | - | - | - |
Very difficult | - | - | - | - |
According to the global assessment of erythropoietin pen device, 144 (56.3%) cases reported “excellent” response. “Very good” and “Good” responses were reported by 106 (41.4%) and 6 (2.3%) patients respectively. No patient reported “Average” or “Not good” response (
A total of 230 (98.7%) patients said that they would prefer to use Erythropoietin Pen device for further treatment too (
Anemia is an early complication of CKD [
of CKD. Higher number of male patients in our survey is in accordance with published data from India [
Recombinant human erythropoietin, the choice of therapy for anemia in CKD patients can be administered by subcutaneous and intravenous route [
Patient training and confidence of patient are critical in long term success with self administration of medicine. The responses for ease of erythropoietin pen device as “very easy” in our study consistently and significantly increased from baseline to visit 2 and visit 3. The study also showed improvement in confidence of self injection at visit 2 and 3.
Delivery device plays an important role in tailoring the dose of ESA in patients with renal anemia [
Pain is an important concern for ESA administration. Efforts have been done to change the buffer or provide local anesthetic cream to reduce the pain with subcutaneous injection [
Storage and disposal of cartridge can sometimes be difficult especially for the agents required for long term use. In this study, large number of patients reported “somewhat easy” to “very easy” storage and disposal.
All these observation including pain and discomfort with injection, confidence in injection, accuracy of dosage and storage and disposal of cartridge can impact global assessment. In accordance with the responses for these individual questions, global assessment of erythropoietin pen device was also very positive. A total of 97.7% patients reported “excellent” or “very good” responses for the global assessment. Despite availability of options of “average” or “not good” response, no patient reported it. Based on their overall satisfaction, 98.7% of the patients said that they would prefer to use this pen device for further treatment too.
Overall, the study observations show confidence and ease of administration of erythropoietin with Wepox PenTM. Routine use of Wepox PenTM has a potential to improve compliance in CKD patients with anemia. Larger studies to confirm improved adherence/compliance with Wepox PenTM are required.
The study is associated with some limitations. Subjective evaluation, convenience sampling and short term follow up limit generalization of observations to all CKD patients. Long term studies to evaluate compliance to treatment and outcomes of anemia in CKD patients are recommended.
Wepox PenTM, a recombinant erythropoietin delivery device with 30,000 IU cartridge is easy to use without significant concern of pain or discomfort in the management of anemia in CKD patients. Moreover, confidence of patient is high while using erythropoietin with this device. Self-administration of erythropoietin with Wepox PenTM makes a significant difference for patients as well as doctors unlike prefilled syringe (PFS) formulation which often requires external help for injection. The reported benefits have potential to improve patient compliance and outcomes of anemia in CKD patients.
Barkate, H., Motlekar, S., Rao, S. and Kamble, S. (2017) Assessment of Patient Perceptions about Use of Wepox PenTM (Recombinant Erythropoietin Delivery Device with 30,000 IU Cartridge) in the Management of Anemia in Chronic Kidney Disease Patients. Open Journal of Nephrology, 7, 38-46. https://doi.org/10.4236/ojneph.2017.72005