The focus of this research is a new type of particle extraction process for the transfer of magnetite nanoparticles from an aqueous to an immiscible organic phase, directly through the liquid-liquid phase boundary in a drop column. The particle extraction process comprises several advantages such as a minimum amount of stabilizing surfactant, no exposure of the particles to a gas atmosphere and with it the avoidance of sintering by capillary forces and a high particle concentration in the receiving phase as well. The study presents experimental results of the characterization of the process environment and the transfer behavior in a drop column. The solution of surfactant in the continuous phase has been investigated during a particle-free phase transfer experiment including the measurements of the total organic carbon (TOC) content and analysis of the size of the stabilized droplets using the laser diffraction spectroscopy. The determination of the transfer fluxes, the mass flows as well as the yield of transferred magnetite by ICP-OES measurements provide information on the impact of interaction of the elementary processes at the phase boundary. Furthermore, the transfer kinetics of the process is described and compared with calculated theoretical values resulting from a kinetic approach.
Because of their special magnetic properties, magnetite nanoparticles have a great potential for many technological applications. Therefore, they are very interesting for a broad range of research areas, for example as magnetic fluids for low friction dynamic gasket systems as well as for the construction of vibration dampers and tweeters [
Possible areas of application for this can be found in the field of reaction engineering [
Emphasis should be put on producing stable colloidal and functionalized particles continuously with a minimum use of surfactants in the liquid organic medium. To demonstrate the continuous phase transfer process via a particle extraction, we design a concept of a miniplant using a drop column as the chosen transfer device. In the literature, the bubble columns with different internals are thoroughly investigated regarding to mass transfer, flow patterns, bubble shapes and hydrodynamics, for example with applications in metallurgical, chemical, bioand petrochemical process industries [
In this study, the particle extraction process is investigated and the results are presented with the drop column in a partial recirculation operation. This means that the aqueous phase is stationary and that the organic phase is in recirculation, as shown in
The process mechanism of the particle transfer in the drop column can be divided into three fundamental steps. At first, the nanoparticles agglomerate partly due to the instable conditions in the aqueous phase as already mentioned in [
Depending on the surfactant used, stable organic colloids are formed by an excellent deagglomeration of the particles and a physicochemical dispersion due to the strong repulsive potential of the adsorbed surfactant molecules [
The aims for the phase transfer process in the drop column are a high efficiency, which means a high yield of transferred magnetite in the organic phase, low transfer times or rather process times and a stable product. Furthermore, a stable process in the drop column is necessary. It means a stable drop formation and upward movement with a sufficient coalescence rate, whereby a clearing off of the column is essential for the setup chosen.
The synthesis of the magnetite nanoparticles with a crystallite size of about 15 nm [
For the phase transfer experiments in the drop column the pH-conditioning of the aqueous phase is necessary; otherwise emulsion formation in the drop column occurs. The aqueous suspension is conditioned under ambient air by repeated washing with distilled water to a pH value of 4 - 5. For the experiments with oleic acid (OA) the original salt concentration of 39.4 g/l and with ricinoleic acid (RA) a quarter of the original salt concentration is utilized. Subsequently, for both surfactants used a process-pH value of 8.10 ± 0.05 is adjusted.
The research of the liquid-liquid particle extraction process in the drop column is effected by the choice of the surfactants, ricinoleic acid and oleic acid respectively. Both are unsaturated fatty acids (FA) at the 9th C-atom with a carbon chain length of 18 C-atoms. RA has an additional hydroxyl-group at the C-atom C12. The surfactants are of technical grade with 90% purity and purchased from Sigma.
The organic phase as the disperse phase is consisting of the solvent iso-octane provided by Carl Roth Germany with 99.5% purity as well as the mass fraction of surfactant xsurf and a specific amount of surfactant per magnetite XS/M. The study presents the results with the parameters xsurf = 1.4 mass-% and XS/M = 0.2 g/g.
All chemicals are used as received.
The magnetite mass concentration is determined with ICP-OES analyses (inductively coupled plasma optical emission spectroscopy) of Fe with the ICP spectrometer iCAP 6300 from Thermo Fischer Scientific. For the measurements, 5 emission lines of Fe with different wave length (Fe238.2 nm, Fe240.4 nm, Fe259.9 nm, Fe274.6 nm, Fe274.9 nm) are used, which cover the whole mass concentration range. For this, the samples were chemically digested with concentrated hydrochloric acid delivered from Carl Roth Germany. For each emission line a triple determination was performed, resulting with a relative standard deviation of <1%.
The total organic carbon (TOC) content measured with the device from analytikjena multi N/C 2100s is determined by using the difference method. This means the total carbon (TC) content is analyzed. After degassing the inorganic carbon (IC) content is measured and subsequently the TOC content can be calculated. If the IC content is negligible the TC-method is used, in which the TC content is measured directly, and this value corresponds with the TOC content.
For the analysis of the size distribution of stabilized droplets by laser diffraction spectroscopy the spectrometer HELOS, manufactured by Sympatec, is used. The measurement range for this device is between 0.1 - 875 µm.
Experimental SetupAs mentioned the drop column as transfer device is used in a partial recirculation operation, that means the aqueous phase is stationary and the organic phase is in recirculation, as seen in
Limited by the dimensions of the transfer device a volume of 300 ml of the magnetite suspension, which corresponds to a mass of 6 g magnetite nanoparticles, is filled into the column as continuous phase. The organic phase, which acts as disperse phase is pumped from the receiver tank through the metal capillary into the drop
column by a supply system consisting of a peristaltic pump (Ismatec Reglo Analog) and a Tygon-tube with an inside diameter of 3.2 mm. Directly above the opening of the metal capillary, whereby dead zones can be formed aside, the organic phase immediately disintegrates in differently sized drops. These rise through the column in the aqueous phase, due to their lower density. The drops transport the extracted magnetite and thus the nanoparticles are concentrated within the coalesced organic phase. The presence of the solvent drops within the column leads to an expansion of the liquid level, the so-called hold-up.
The organic phase containing the extracted magnetite particles is collected at the top of the liquid and pumped back to the receiver tank through the removal system. Due to the fact that surfactants are used, the rising drops can form a so called dispersion ribbon at the surface of the continuous phase. This is a layer consisting of droplets and only partial hydrophobized particles, where the coalescence is hindered [
Due to the hydrodynamic dead time the first measuring point can be taken after 85 seconds, because then organosol is existent in the removal system. The average resistence time in the column is about 51 seconds and the volume flow rate is 29 ml/min. The sample volume amount is 2.9 ml and is added at the same time manually as pure organic phase in the receiver tank, hereby keeping the volume of the disperse phase constant during the recirculation. However, after each removed sample volume the amount and mass concentration of magnetite nanoparticles in the system is reduced, which is included in the calculation of based on the validation of the system.
For the evaluation of the corrected mass concentration of transferred magnetite nanoparticles in the receiver tank a verification of the system is applied taking into consideration the input and output to the receiver tank as well as the residence time distribution in Equation (1):
where is the initial mass concentration of the system, is the volume in the receiver tank, is the volume flow of the disperse phase and is the auxiliary variable, which describes the time of the entry.
By linear interpolation and numeric integration, the Equation (1) can be solved. This results in the following equation:
where as well as are formed by linear interpolation between the removed samples.
To characterize the process environment we have investigated the procedures in the drop column by the method of a particle-free operation, whereby the changes in the column can be observed. At defined time points the pumps were switched off and the sampling is effected from the continuous phase. In dependence from surfactants used the different mechanisms of drop formation of the disperse phase in the column is demonstrated in
As mentioned above the both surfactants used have a different process behavior with varying consequences to the particle extraction process. The turbidity in the column with ricinoleic acid as surfactant does not influence the process stability of the phase transfer, because the disperse phase can be performed in recirculation without hindrance. The reason for the formation of small emulsion droplets is due to the mass transport of ricinoleic acid through the phase boundary. This is possible, because ricinoleic acid is soluble in the organic as well as in the salts and ammonia containing aqueous phase owing to the additional hydroxyl group. This effect of the spontaneous formation of an emulsion has been described relating to a pH value dependency of Stackelberg, 1949 [
To prove the solution of surfactants from disperse into continuous phase the TOC content in the aqueous phase is determined and plotted as a function of the time, as shown in
mental procedure. Whereas oleic acid (
So the TOC values of oleic acid actually dissolved in the aqueous phase are nearly in the range of 0.01-0.03 g/l. Comparing the average values of the mentioned ranges (2 g/l for ricinoleic acid and 0.02 g/l for oleic acid), it can be recognized that in contrast to oleic acid approximately the 100-fold amount of ricinoleic acid is dissolved in the aqueous phase irrespective of time.
Furthermore, experiments are performed with a pH-indicator bromothymol blue in the continuous phase, as demonstrated in
the continuous phase (
This finding implies that more than one process is relevant at the phase boundary.
For the characterization of the transfer behavior the yield of transferred magnetite particles is plotted against the process time in
Based on the short-time trial with the process time limit of about 10 minutes it can be observed excellently, that the phase transfer with ricinoleic acid as a surfactant takes place rapidly. The increase of the yield of transferred magnetite is nearly twice the amount compared to oleic acid. This is consistent with the significant increase in TOC content, because by dissolving of ricinoleic acid in the aqueous phase the drops disintegrate more easily and thus an additional phase boundary can be formed for the phase transfer process. Due to the lower solution of oleic acid in the aqueous phase the available phase interface is smaller, which leads to longer process times for the phase transfer of magnetite. This also can be observed during the long-time trials with both surfactants. With ricinoleic acid it can be demonstrated, that already after 15 minutes the yield of transferred magnetite amounts to approximately 90% and it is kept constant about over time, up to 165 minutes. However, with oleic acid the transfer is completed after nearly 270 minutes and the maximum with a yield of transferred magnetite of about 86%. Furthermore, the clearing off of the column with ricinoleic acid as surfactant is obtained after about 6 minutes, whereas with oleic acid it can be achieved only after 160 minutes.
For the characterization of transfer kinetics, the mass flow of transferred magnetite particles is plotted against the process time in
The plot of the mass flow with ricinoleic acid as a surfactant is conspicuously distinguished by the increase from the first measuring point at 85 seconds till the maximum of the mass flow at a process time between 4 - 5 minutes. During this initial phase the ricinoleic acid concentration in the aqueous phase still rises, which limits the mass flux of magnetite. Subsequently, the mass flow is described with a kinetic of 1st order as it is also identified with oleic acid as surfactant, what needs to be proved.
In the present case the product of functionalized magnetite particles (B) are formed from the precursor of pure
magnetite nanoparticles (A) in Equation (5).
It is supposed that the already transferred magnetite concentration in the organic phase does not influence the transfer process. With this assumption the drop column can be seen as conventional tank reactor [
Thereby, the differential temporary law of the reaction can be established in Equation (6). This indicates, that the temporal change of mass concentration is proportional to the currently existing mass concentration .
where is the rate constant of reaction (1/s) of the 1st order and the product is the rate of consumption of A. Furthermore, the half-life for the reaction of both surfactants can be determined from the experimental data. The half-life is the time, at which half of the precursor is dissipated. By means of
The relative change in the mass concentration in Equation (8) is proportional to the temporal change . It can be calculated from the experimental data by the ICP-OES measurements and is demonstrated in
By integration from till end time as well as from initial mass concentration till and additional by the use of logarithmic, the integral temporary law is achieved in the following equation:
resulting in the determination of the theoretical mass concentration and using the Equation (10) for the calculation of for both surfactants derived from Equation (9)
Hence, the theoretical relative change in the mass concentration can be calculated and compared to the experimental calculated plots (
Based on the comparison in
whereby and the theoretical lower and upper thresholds of the curve. Due to the fact that possible values for lie in the range {0…1}, and can be defined with 0 and 1, respectively. Furthermore, Equation (11) has a negative first derivation and, more important, one point of inflection, which demonstrates the local maximum of the mass flow at a process time between 4 - 5 minutes (
In this work, the particle extraction process with a drop column as transfer device in partial recirculation operation has been investigated. The material parameter of the suspension are chosen to be constant with surfactant concentration xsurf = 1.4 mass-% and the optimal specific amount of surfactant per magnetite XS/M = 0.2 g/g. For these parameters, secondary effects like water inclusion and emulsion formation can be excluded, because a stable process behavior with a complete clearing off the column as well as a sufficient coalescence rate can be achieved. Based on the modeling of the system, we are able to evaluate the transfer fluxes. Thereby, yields of transferred magnetite nanoparticles are obtained >80%. Furthermore, for the characterization of the process environment, we have chosen a particle-free phase transfer as an indicator. In combination with optical changes in the column as well as measurements of the total organic carbon (TOC) content and the size distribution using laser diffraction spectroscopy, we have proven that ricinoleic acid helps disintegrating iso-octane. Droplets with a median particle size of 5 - 10 µm are formed. This is particular difference in comparison to oleic acid and this is due to the chemical structure of the surfactants. Therefore, it is possible that additional phase interfaces are formed for the phase transfer process, which further determines the transfer times of particles by reduction of the interface tension. As a consequence of this, we have described the interaction of the processes and procedures at the phase boundary. Thereby, we have a mass transport of the surfactant from disperse into continuous phase on the one hand, which determines the process time for the phase transfer, and simultaneously the phase transfer of the magnetite nanoparticles on the other hand. This interconnection is reflected in the transfer kinetics of either surfactant. Finally, we have determined that the particle extraction process with oleic acid as a surfactant can be estimated as a reaction of 1st order. Thus, the influence of the surfactant mass transfer of the process kinetics is negligible. However, in the case of ricinoleic acid as surfactant, another approximation has to be used to describe the particular process behavior. This is represented by a sigmoid function in terms of a dose response curve. Therefore, the mass transport of the surfactant due to dissolving strongly influences the process kinetics.
Advanced studies in the process development of a continuous liquid-liquid phase transfer to obtain highquality organosols will be presented soon regarding to produce stable colloids and interaction between the surfactants and organic phase used.
The authors would like to thank the German Research Foundation (Deutsche Forschungsgemeinschaft DFG) for financial support by grant PE1160/6-3 and we give thanks to Andre’ Rieger as well as the laboratory technicians from Institute of Thermal Process Engineering, Environmental and Natural Products Process Engineering of TU Bergakademie Freiberg for the TOC measurements.