The principal factor to determine the economical value of the products manufactured in the electronics industry is due to the productive yielding. This is important for the cost of the articles fabricated in this type of industrial plants installed in Mexicali city, where around 80% of companies are, and which fabricate electronic devices and systems, or have industrial electronic systems and machines to their manufacturing process. Mexicalicity is located in theBaja CaliforniaStateof the northwest ofMexico, which is a border city with Calexico in theCaliforniaStateof the United States of America (USA). The region located in Mexicali, is a desert area. Geothermal plant is located in this area, which is an important industry and supplies electricity to this city and its valleys and some cities on southwest of United States for daily activities. This company emits hydrogen sulfide (H2S) as a main air pollutant that reacts with oxygen in the atmosphere, generating sulfur oxides (SOX). This chemical is dispersed to the city of Mexicali in which industrial plants are located with electronic control systems, and penetrates to indoor rooms. Those cause the corrosion process. The presence of corrosion leads to the deterioration of electrical connectors, the connections of electronic systems and the decreasing of the lifetime of these control systems. Other air pollutants that are considered as chemical agents which cause damage to materials used in the electronics industry, are the sulfurs and nitrogen oxides (NOX), emitted from the traffic vehicle and some industries. This causes the low productive yielding of electrical and electronic devices and systems used in the companies of this city, and is a major concern to specialized people, managers and owners. To analyze the productive yielding of electronic devices and systems installed in indoor of the electronics industry. For this reason, to know the principal causes of it, a study in three industrial plants, to determine the grade level of deterioration of the electronic control systems (ECS) used in the electronics industry of this city was made. The results showed that at major air pollution concentration detected by specialized methods, the lifetime of the ECS was decreased by the generation of corrosion in their electrical connectors and connections. This was caused for the levels of air pollutants mentioned above, than exceed the air quality standards in some periods of the year, added with the levels upper of relative humidity levels (RH) and temperatures of 85% and 25°C in winter and 80% 35°C in summer, being a main factor of this electrochemical phenomenon.
The permanence of an industrial plant in the world marketing depends on their planning production in their manufacturing processes, including the methods of fabrication, and where specialized people are monitoring the productive yielding of the ECS [
The world marketing competition, has led to develop technological advances, particularly in the area of the electronics, which are increasingly being manufactured microelectronic components, very robust and with a greater number of operations. The tendency to miniaturization of the technology is a leader in the development of equipment electronics such as cell phones, computers, televisions and a lot of electronic devices. Materials used in the electronic components are alloys based especially on aluminum (integrated circuits with at micro and nano size of wire), copper contacts nickel electroplated with gold to improve the resistance to corrosion, but increase the cost of this [
corrosion damage tolerance in electronic components is of very small order of magnitude at 10 to12 nano grams. According to the research studies, the order of the width of the films of electronic boards is of 50 microns, and in hybrid circuits (HC), the space should be of 2.5 microns. This type of microelectronic devices corroded is shown in
As shown in
The electronic boards suffer a variety of problems in their electrical conduction surfaces by the presence of the air pollutants as sulfurs principally and the levels of RH and temperature. When its parameters are combined, the atmospheric agents react very easy and quickly with the metallic surfaces, decreasing the resistance to the corrosion of the connectors and electrical conductive paths. This causes the formation of metallic filaments that grow between routes where not debit growth, causing electrical conductivity between terminals metal (pins), or metallic unions [
As shown in
The climatic factors generate the dispersion of air pollutants such as fine particles and gases: hydrogen sulfide,
sulfur dioxide and nitrogen oxides principally. These air pollutants, sometimes exceed the standards of air quality in this region. These contaminants are detected by specialized teams of Environmental Monitoring Stations (EMS) installed in strategic places of the Mexicali city. These chemical agents are emitted by external sources such as traffic, industrial plants, geothermal fields, soil erosion and microorganisms, which penetrate to the indoor of the electronics industry. At levels higher than 75% 25˚C of RH and temperature, that is common in some periods of the year in Mexicali, are obtained the time of wetness (TOW), indicating the periods in which the metallic surfaces of microelectronic devices kept moist for at least one day, causing the electrochemical corrosion process. The pollution levels are evaluated according to standard regulations that indicate the concentration levels regulated by environmental institutions in each country. In Mexico, the Secretaria del Medio Ambiente y Recursos Naturales (SEMARNAT), in mutual agreement with the Environmental Protection Agency (EPA) of USA [3,7], are responsible for the regulation of the pollution emissions of the outdoor and indoor of the industrial plants. With international agreements, on the border of Mexico and the United States, SEMARNAT and the EPA, have installed Environmental Monitoring Stations (EMS) and Meteorological Monitoring (MMS). With thus systems are obtained information of outdoor pollution that affects indoor atmospheres of the electronic industry, at high levels of air pollution and with drastic variations of RH and temperature, showing diverse values in different seasonal periods. The chemical agents, which are monitored by the EMS in this city, are H2S from the geothermic plant, sulfurs dioxide(SO2), carbon monoxide (CO), nitrogen oxides (NOX), ozone (O3) and particulate matter (PM10 and PM2.5), which are reported by the National Ambient Air Quality Standards (NAAQS, 2006). Additionally are monitored the volatile organic compounds (VOC) generated in indoors of the companies by specialized techniques. Also this monitored ammonia that is inorganic agent and has an effect on the deterioration of metallic connectors and connections of the ECS, and even at low concentrations, have a significant effect on the corrosion phenomenon [
According to the humidity originated in indoors of industrial plants, material of electronic devices generates different corrosion processes, such as those explained below [
A) Corrosion voltaic. This type of corrosion is generated in a small space between electronic circuit components, when a voltage is applied to a device, generating the voltage gradients in order of micro-volts in electrical connectors and connections, resulting in accelerated electrochemical corrosion reactions and ion migration. The integrated circuits are very susceptible to corrosion. The combination of electrical fields, with atmospheric humidity and air pollution are the main promoters of this type of corrosion in metals used in the microelectronic devices. The corrosion can occur only with the presence of low humidity in sometimes. The pH generated by a cathodic reaction is for the reduction of water. High pH levels result in a solution in the passive film, with a surface of the metal oxide and aluminum substrates and increases the electrical resistance, generating an open circuit.
B) Electrolytic metal migration. In presence of moisture and an electric field, silver ions migrate to a charged surface cathodically, forming dendrites, which grow as bridges between contacts, possibly causing short circuits to reduce the production yielding of the ECS and decreasing their life time, and in sometimes causing fires. Always a small volume of the dissolved metal forms the dendrites as a large pathway. Other materials which are susceptible to metal migration ions are the gold, tin, lead, palladium and copper. Dendrites can be of silver, copper, tin, lead or combination of these metals and cause electrical failures in the microelectronic devices and also to ECS, by short circuits. The dendrite is generated and grows very fast between electrical connectors and connections originating electrical failures in the ECS. The growth rate of dendrite depends on the applied voltage and the amount of contamination atmospheric combined with the moisture, which affect the metal surface.
C) Formation of pores and cracks in electrical contacts and connections metal. To prevent the connectors and electrical contacts stained by the corrosion process in metals such as gold, the process is performed on the surface of silver contacts and connectors. However, defects in protective coatings of metals can expose and corrode the substrate material and create imperfections like pores and cracks. If the substrate is copper or silver, and it is exposed to environments with sulfates or chlorides, the products corrosion, cracks will generate pores, and if gold added to silver forms a high resistance in the conductive layer, whereby open circuits are generated.
D) Fretting corrosion on separate jacks with fine finishes. It results in the formation of tin oxides boards electronic or electrical contacts. The problem starts very often when the tin is used or replaced by gold metal, being more economical. The possible solution is to replace the hand or use a little more expensive metals.
E) Galvanic corrosion. It occurs when two different metals, such as aluminum and gold come together, as it is in the encapsulation of integrated circuits. The polymers used are packaging as a pair porous and plastic tapes that seal metal joints are manufactured as electronic devices ceramic or metallic. Sometimes, humid environments generate galvanic corrosion conditions.
F) Corrosion in industrial processes. Integrated circuits are environments exposed to numerous aggressive attack ionic or wet and aluminum, which are the main compounds. The ion etching requires a combination of gas and if this is formed as chlorides aluminum covering the metallic structures of the ECS, which are acidic agent and generates acid moisture. The ionic contamination occurs in soldering processes and handling of materials used to fabricate microelectronic devices with very thin films, originated by dust and changes climate.
G) Microcorrosion in the manufacture of integrated circuits. The metallization of aluminum and copper alloys can form inter-metallic compounds like Al2Cu with a large grain boundaries. This is the beginning of the dissolution of metals which form a micro-pitting during the etching.
H) Corrosion by chlorinated solvents or halogenated. Liquid solvents steam or used in the manufacture of integrated circuits, are mainly the factors which corrode aluminum components. Contaminated water of solvents increases the time of the presence of corrosion and also increases the corrosion rate, which is the speed at a metal which disintegrates. The stabilized solvent dissolution with alcohol or aromatic solvents is the main cause of halogenated solvents breaking and forming chlorine ions, corroding the aluminum and copper alloys, with major effect in the aluminum.
I) Corrosion in welding. Corrosion resistance joints of tin and lead in aqueous and gaseous environments is a function of the alloy. This significantly improves when increases more than 2 times the rate of the alloy. Lead forms unstable oxide, which reacts readily with chlorides, borates and sulfates.
The topography of the Mexicali city is important to the dispersion of the air pollutants mentioned above, penetrating to indoor of the electronics industry where there are about 156 industrial plants according to the Asociación de Maquiladoras de Mexicali (AMAQ) [
MATLAB is software called Matrix Laboratory, being mathematical programming that offers integrated development environment (IDE) with proprietary operations of language called language M. It has basic features as array manipulation, data representation and functions, implementation of algorithms, creation of user interfaces as GUI and communication with programs in other languages and other hardware devices [
Humidity and temperature are the two most important climatic parameters related to the origination of the corrosion process. For this study was used information of the air pollutants mentioned above, and also the temperature and RH of 2010 to 2011 obtained of the specialized equipments and the EMS. Based on the statistical information of the climate factors was made an analysis of the generation of the different types of corrosion in the ECS, which use microelectronic devices. According to the emission supplies, the levels of air pollution are concentrated in some areas of Mexicali, principally where are located the electronics industry. In Mexicali the temperature is very hot in summer until major of 45˚C in some periods of this season and very cold nights until near of 0˚C in the winter. The maximum and minimum recorded monthly periods of RH and temperature of indoors of industrial plants, showed ranges varying under 10% and above 90% for RH in summer and winter, and temperatures in the winter of 0˚C to nearly 50˚C in the months of June to August. The TOW monthly values correspond to low and medium levels of corrosivity, with ISO 9223 and ISO 11844-1 [12-14]. The study was made in three industrial plants of this city principally of the electronics area from 2010 to 2011.
The levels of RH and temperature promote the process and influence the dispersion of air pollutant from natural and anthropogenic sources, causing the corrosion process. In the summer the atmospheric pollution, is based on the temperatures in the range from 30˚C to 42˚C and the RH levels ranging from 55% to 85% with a higher intensity is observed of 90%, representing high dispersion of air pollutants and in winter at temperatures near of 0˚C are presented low dispersion, remaining near of the industrial plants and penetrating to its companies. This originates in some periods of the year and some areas, a high concentration of pollutants, increasing the CR and the deterioration of the metallic surfaces of ECS.
The CR was influenced by the exposition at different levels of the air pollutants, damaging the microelectronic devices. In this study a correlation analysis was made to know the grade of deterioration of the micro components of the ECS. At different levels of RH, temperature and concentration levels of air pollution, were obtained diverse values of correlation, indicating the major indices in winter where occur the condensation phenomenon and the fast and easy adherence of the air pollutants, as shown in