A 54-year-old man was referred for ablation of symptomatic drug-refractory long-lasting persistent atrial fibrillation. His past medical history was negative for cardiac disease but included a diagnosis of esophageal achalasia. The patient underwent an ablation procedure, guided by barium esophagram, including isolation of the pulmonary veins, ablation of complex fractionated left atrial electrograms recorded on the sep-tal wall and, finally, linear ablation of the cavo-tricuspid isthmus. The ablation procedure was performed with multielectrode ablation catheters using duty-cycled bipolar/unipolar radiofrequency energy. During 6 months of follow-up no recurrences of atrial fibrillation were documented. The reported case demonstrates how an ablation procedure for long-standing persistent AF may be safely performed even in a patient presenting with a achalasia, outlining the mega-esophagus position with a simple barium paste.
At the present time, a number of different approaches are being employed to avoid esophagus-related complications during atrial fibrillation (AF) ablation procedures [1-6]. Barium paste, outlining the esophageal position in real time for the duration of the procedure, may provide an effective approach to minimize the potential risk of thermal injury when delivering radiofrequency (RF) energy at the posterior wall of the left atrium (LA), in close proximity to the esophagus [
In the case we here report barium esophagram was successfully used to perform safely RF ablation of longstanding persistent AF in a patient with a megaesophagus due to achalasia, a rare neurodegenerative disease resulting in abnormal esophageal motility and impaired relaxation of lower esophageal sphincter [
A 54-year-old man with symptomatic drug-refractory longstanding persistent AF was referred for catheter ablation after two failed electrical cardioversion. His past medical history was negative for structural heart disease but included a diagnosis of esophageal achalasia established 3 years earlier.
On admission, cardiac and chest computed tomography (CT) documented four distinct pulmonary veins (PVs) connecting with a LA, being partially compressed by an evident mega-esophagus (
After outlining the mega-esophagus position with a small barium paste, swallowed by the patient prior to conscious sedation, a 3-step ablation procedure was performed with multielectrode ablation catheters using dutycycled bipolar/unipolar RF energy, (Medtronic - Ablation Frontiers, Carlsbad, CA, USA). Initially, electrical isolation of the four PVs was performed with a decapolar, circular, over-the-wire mapping and ablation catheter (
While in the pre-ablation CT scan the mega-esophagus appeared directly adjacent to the posterior LA, during ablation fluoroscopy documented a significant separation between its lumen and the LA border, as a result of the spontaneous displacement of the esophagus. Accordingly, RF energy was safely delivered at an adequate distance from the esophagus and the ablation procedure was successfully performed with no complications. Two days after ablation the patient was discharged on therapy with warfarin and with a 3-month prescription of amiodarone. During 6 months of follow-up no recurrences of AF as well as no esophagus-related complications were documented.
The close proximity of the esophagus to the posterior LA has increasingly been emphasized in the last years to explain the rare but devasting cases of atrioesophageal fistula related to AF ablation procedures [
Barium paste, monitoring in real time the spontaneous movements of the esophagus relative to the posterior LA [
Considering the intimate relationship of the esophagus with the LA, it is conceivable that the risk of thermal injury, during AF ablation, may result significantly increased in patients presenting a dilated esophagus compressing the posterior LA. The reported case demonstrates that even in a patient with a mega-esophagus due to achalasia, an ablation procedure of long-standing persistent AF may be safely performed, after obtaining real time monitoring of the mega-esophagus position with barium paste.
Barium esophagram seems to provide an accurate anatomical guidance to minimize the potential risk of thermal injury, during AF ablation procedures, even in patients presenting with mega-esophagus.
The authors thank biomedical engineer Simona Benedetti (Medtronic, Italy) for her expert technical support.