Journal of Applied Mathematics and Physics
Vol.06 No.09(2018), Article ID:87482,9 pages
10.4236/jamp.2018.69162

Parameters Effect on Heat Transfer Augmentation in a Cavity with Moving Horizontal Walls

Doli Rani Pal1*, Goutam Saha1, Kajal Chandra Saha2

1Department of Mathematics, University of Dhaka, Dhaka, Bangladesh

2Department of Applied Mathematics, University of Dhaka, Dhaka, Bangladesh

Copyright © 2018 by authors and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY 4.0).

http://creativecommons.org/licenses/by/4.0/

Received: August 14, 2018; Accepted: September 22, 2018; Published: September 25, 2018

ABSTRACT

Mixed convection flow is one of the essential criteria of fluid flow and heat transfer. And its application has been increased due to modernization of society. So, to compete with the global world an analysis has been investigated numerically. In this study we have considered 2D double lid driven cavity with two-sided adiabatic walls. This problem is illustrated mathematically by a collection of governing equations and the developed model has been solved numerically by using Finite Difference Method (FDM). The goal of the present study is to analyze numerically the thermal behaviour and parameters effect on heat transfer inside the 2D chamber. Also this analysis has been observed for the case where the upper wall is moving at positive direction and lower wall is moving at negative direction with constant speed. Furthermore, we have tried to analyze the velocity and temperature profiles for a vast range of dimensionless parameters namely Reynolds number ( Re ) , Richardson number ( R i ) and Prandtl number ( Pr ) and presented graphically. Moreover, it is found that these flow parameters have significant effects in controlling the flow behavior inside the cavity. A comparison has been done to validate our code and found a good agreement. Finally, average Nusselt number ( N u ) has been studied for the effects of these parameters and presented in tabular form.

Keywords:

Mixed Convection, Nusselt Number, Lid-Driven Cavity, Heat Transfer, Shear Force

1. Introduction

Mixed convection, takes place when natural convection and forced convection mechanisms perform simultaneously to exchange heat due to temperature differences. This is likewise characterized as circumstances where both pressure and buoyancy forces interface. The heat transfer behavior of the fluid as convection is mostly depended on the flow, temperature, geometry and inclination. In recent years, the natural and mixed convection flow has gained interest from their hypothetical and practical perspectives.

“The double lid-driven cavity problem has been gained extensive interest among the scientists and researchers because of its simplest geometrical settings with all fluid mechanical structure and applications such as cooling of electronic gadgets, drying instrument, softening procedures and so forth. Additionally, movement of side walls is also responsible for the fluid convective behavior within the enclosed square cavity” [1] . Furthermore, many numerical investigations are examined on double lid driven square cavities [2] - [15] .

In recent past, Pal et al. [1] performed a numerical experiment on a lid driven cavity for low Re flow using Finite Difference Method (FDM). Therefore, we observe that no investigation has been done on the behaviors of heat transfer filled with air/water inside a square enclosure where the upper and lower walls are moving at constant speed and side walls are adiabatic. In this study, we have considered low and high Reynolds number flow to examine heat transfer properties. In such manner, the goal of this investigation is to review the behavior of fluid and temperature fields for various Re , R i and Pr in a double lid driven square domain. Moreover, average Nusselt number ( N u ) is investigated in order to see the performance of the heat transfer inside the chamber.

2. Governing Equation

In the present experiment, a steady state, incompressible flow inside a cavity has been studied. The physical model along with boundary conditions is shown in Figure 1. To continue study, we have considered the case where the horizontal upper hot wall is moving towards and lower cold lid is moving backwards at a constant velocity. However, left and right side vertical wall are kept adiabatic in each case.

The following governing equation has been presented for 2D and incompressible flow in non-dimensional form:

U X + V Y = 0 (1)

U U X + V U Y = P X + 1 Re ( 2 U X 2 + 2 U Y 2 ) (2)

U V X + V V Y = P Y + 1 Re ( 2 V X 2 + 2 V Y 2 ) + R i θ (3)

U θ X + V θ Y = 1 P r R e ( 2 θ X 2 + 2 θ Y 2 ) (4)

Figure 1. Simplified diagram of the physical geometry.

where U and V are the velocity components along X and Y directions, θ is the non-dimensional temperature and P is the non-dimensional pressure component. Here, the dimensionless parameters in Equations (1)-(4) are: Ri is the Richardson number, Re is the Reynolds number, Gr is the Grashof number, is the Prandtl number. The governing parameters in Equations (1)-(4) and non-dimensional length and velocities are as follow:

X = x L ; Y = y L ; U = u V L ; V = v V L ; P = p ρ V L 2 ; θ = T T C T H T C ;

R i = G r R e 2 ; R e = V L L ν ; G r = g β Δ T L 3 ν 3 ; P r = ν α ;

where ρ , g , α , β and ν are the fluid density, gravitational acceleration, thermal diffusivity, the coefficient of thermal expansion and kinematic viscosity, respectively. The velocity and temperature flow fields boundary conditions are shown in Figure 1 and have the following dimensionless form:

U = V = 0 , θ x = 0 at X = 0 and X = 1 U = 1 , V = 0 , θ = 0 at Y = 0 U = 1 , V = 0 , θ = 1 at Y = 1 } (5)

Also, the definition of local and average Nusselt number is described in Pal et al. [1] .

3. Numerical Procedure and Validation

We have used finite difference method to deal with the governing equations (1)-(4) along with the boundary situation (5). Then an in house code (DGK) has been implemented to represent the flow and thermal behaviors. However, grid independent test has been done to verify the code which is also presented in Pal et al. [1] . Furthermore, numerical approximation and comparison has been examined graphically for centerlines velocity profiles with Adair et al. [16] , Ghia et al. [9] and found good harmony. Another study has been presented for average Nusselt number by using Simpson’s 1/3 rule to approve the code and validate result with Abu-Nada et al. [7] , Waheed et al. [5] and Sharif et al. [17] . Aspects of these studies have been discussed in Pal et al. [1] .

4. Result and Discussion

In this research, variation of velocity and temperature profiles with different Re, Ri and Pr inside the square cavity with the given boundary conditions (5) are studied and explained graphically in Figures 2-4. Additionally, variation of average Nusselt number has been studied and presented in tabular form in Table 1. The dimensionless parameters considered here are 100 ≤ Re ≤ 1000, 0.1 ≤ Ri ≤ 3.0 and 0.71 ≤ Pr ≤ 10.

The flow and thermal fields within the double lid driven cavity for Ri = 1.5 and Pr = 10.0 are represented in Figure 2 for numerous values of Reynolds number. This profiles shows that for Re = 500 fluid flow develops a high speed velocity region near the moving lid. For the moving lids, there appear two large secondary vortices in the two opposite corner and two tiny secondary vortices in the center of the cavity. The flow is dominated by the forced convection and due to high temperature difference along the moving lids, the flow field becomes more turbulent. Furthermore, the size of the secondary vortices increases with the increase of Re to 1000. Moreover, two tiny secondary eddies as it is located at the center of the cavity form another convective cell inside it which seems to be chaotic. From temperature profiles in Figure 2, there occurs high temperature

Table 1. Variation of average Nusselt number for different Re, Pr and Ri.

Figure 2. Variation of velocity and temperature profiles with different Reynolds number for Ri = 1.5, Pr = 10.0.

Figure 3. Variation of velocity and temperature profiles with different Richardson number for Re = 100, Pr = 10.0.

Figure 4. Variation of velocity and temperature with different Prandtl number for Re = 100, Ri = 0.1.

difference region near the moving lid for Re = 500. Additionally, the center thermal region separate into two parts. One part moving towards the hot region and another part moving towards the cold region. These all makes a steep temperature gradient along the adiabatic wall. This is due to the presence of shear stress. As an increase of Reynolds number Re = 1000, shows hot fluid mixes up with the cold fluid very well and the thermal boundary layer diminishes.

Figure 3 represents the variation of velocity and isothermal profiles for miscellaneous values of 𝑅𝑖 with fixed Re = 100 and Pr = 10.0. Usually, the flow seems to be dominated by the mixed convection for 0.1 < Ri < 10. From velocity profiles for Ri = 1.0, it is observed that the upper and lower secondary cells are moving in the clockwise pattern due to the movement of the upper and lower walls. Moreover, it creates high speed velocity region near the velocity boundary layer and it covers most of the cavity. However, two small eddies have been visible near the vertical walls. Besides, the tiny secondary vortices tend to merge and finally form a large secondary vortex for Ri = 1.5, 3.0 in the core of the cavity which may control the flow field with further increment of Ri. As a result, dominant secondary vortices are decreased in size. In this regard, buoyancy effect is clearly seen in velocity profiles. From Figure 3, it is seen that shear powers are prevailing in the cavity and, subsequently, the isotherms are generally assemble to the region close to the top and bottom surfaces of the square cavity for Ri = 1.0. The high temperature inclination close to the upper and lower walls is because of these high shear stress created due to moving lids. Also, a thin thermal boundary layer has developed on the top of the hot lid. Besides, mid temperature zone is visible in the center of the domain. Now if we look forward, expanding 𝑅𝑖 up to 1.5, the shear forces and buoyancy forces are a similar extent. In this way, coarse isotherms existed close to the top and base walls. Therefore, a direct temperature difference in the vertical direction can be seen. Additionally, increments in Ri (Ri = 3.0) prompt more extensive development of isotherms covering the entire cavity. This leads a further abatement of the heat exchange strength the along moving lid because of a dynamically stable free convection impact. Along these lines, the buoyancy force characterizes the shaped fluid stream and heat exchange inside the domain.

Figure 4 represents the isothermal profiles for various Pr such as Pr = 0.71, 2.0, 5.0, 10.0 and taking the other dimensionless numbers such as Re = 100 and Ri = 0.10 as constant. If we consider the velocity profiles in Figure 4 for various Prandtl number then it is observed that velocity profiles is independent of Prandtl number. There exists a primary eddy for Pr = 0.71 and when Pr increases for the next three cases, there is no significant differences on the flow field. Because for Ri < 1.0 the flow is commanded by the shear force inside cavity and determines the temperature and buoyancy variations in the cavity. It shows strong dependency on Pr. From Figure 4, it is seen that there is a development of higher temperature difference zones located near the two opposite corners due to the adiabatic walls. As we increase the Prandtl number (Pr = 2.0), the temperature patterns are trying to twist due to the forced convection. Moreover, the thermal boundary layer thickness decreases so the average Nu increases with the higher values of Pr. In addition there exists a large isotherm region in the core of the cavity and tend to increase if Pr increases more.

Table 1 represent the average Nu for wide range of different dimensionless parameters such as Re, Pr and Ri. Further, it is seen that percentage enhancements of avg. Nu are 45%, 65% and 73% respectively for Re = 100 and Pr = 2, 5, 10. Moreover, such percentage enhancements of avg. Nu are 74%, 80% 88% respectively for Re = 500 and Pr = 2, 5, 10. Also increment in percentage of the rate of heat transfer are 76% 80% 87% where Re = 1000 and Pr = 2, 5, 10, in all these cases keeping Ri = 0.1. More precisely, the maximum heat transfer difference almost 10% occurs when we consider Re = 100 and Re = 500. After that, it reduces to almost 2% to 3% between Re = 500 to Re = 1000. Thus we can conclude that if 𝑃𝑟 increase then the heat transfer rate increases. Also, highest heat transfer rate occurs for small values of Ri. Highest heat exchange attribute occurs for Ri = 0.1 which is fallen by almost 40% for Ri = 1.0. Finally, the heat transfer rate slightly decreases with the increase of Ri.

5. Conclusion

The flow phenomena and heat transfer are observed inside a bounded domain where the upper wall is moving in the positive direction and lower wall is moving in the negative direction. The geometrical characteristics have been set to the Equations (1)-(5) and then solved by 4th order FDM. The effects of dimensionless parameters Re, and Pr have been presented graphically and in tabular form. It is noticed that there is no effect of Pr on the velocity profiles but strong effect on temperature profiles. Also, it is found that for increasing of Ri, rate of heat exchange decreases. Besides, for low Richardson number flow is dynamically unstable and for higher values of Ri, the flow is stable. Furthermore, as Re increases, the augmentation of average Nu increases for all cases. Overall, higher intensification of average Nu is pragmatic when flow becomes turbulent and deterioration of average Nu can be realistic when flow becomes laminar.

Acknowledgements

This work has been fully supported by University Grant Commission (UGC), Bangladesh via grant number Reg./Admin-3/76338 (Year: 2017-2018).

Conflicts of Interest

The authors declare no conflicts of interest regarding the publication of this paper.

Cite this paper

Pal, D.R., Saha, G. and Saha, K.C. (2018) Parameters Effect on Heat Transfer Augmentation in a Cavity with Moving Horizontal Walls. Journal of Applied Mathematics and Physics, 6, 1907-1915. https://doi.org/10.4236/jamp.2018.69162

References

  1. 1. Pal, D.R., Saha, G. and Saha, K.C. (2018) A Case Study of Double Lid Driven Cavity for Low Reynolds Number Flow. Dhaka University Journal of Science, 66, 95-101.

  2. 2. Ramanan, N. and Homsy, G.M. (1994) Linear Stability of Lid-Driven Cavity Flows. Physics of Fluids, 6, 2690-2701. https://doi.org/10.1063/1.868158

  3. 3. Iwatsu, R., Hyun, J.M. and Kuwahara, K. (1992) Convection in a Differentially Heated Square Cavity with a Torsionally-Oscillating Lid. International Journal of Heat and Mass Transfer, 35, 1069-1076. https://doi.org/10.1016/0017-9310(92)90167-Q

  4. 4. Iwatsu, R., Hyun, J.M. and Kuwahara, K. (1992) Numerical Simulation of Flows Driven by a Torsionally-Oscillating Lid in a Square Cavity. Journal of Fluids Engineering, 114, 143-149. https://doi.org/10.1115/1.2910008

  5. 5. Waheed, M.A. (2009) Mixed Convective Heat Transfer in Rectangular Enclosures Driven by a Continuously Moving Horizontal Plate. International Journal of Heat and Mass Transfer, 52, 5055-5063. https://doi.org/10.1016/j.ijheatmasstransfer.2009.05.011

  6. 6. Chen, C.J., Nassari-Neshat, H. and Ho, K.S. (1981) Finite-Analytical Numerical Solution of Heat Transfer in Two Dimensional Cavity Flow. Numerical Heat Transfer, 4, 179-197. https://doi.org/10.1080/01495728108961786

  7. 7. Abu-Nada, E. and Chamkha, A.J. (2010) Mixed Convection Flow in a Lid-Driven Inclined Square Enclosure Filled with a Nanofluid. European Journal of Mechanics—B/Fluids, 29, 472-482. https://doi.org/10.1016/j.euromechflu.2010.06.008

  8. 8. Aydin, O. (1999) Aiding and Opposing Mechanisms of Mixed Convection in a Shear and Buoyancy Driven Cavity. International Communications in Heat and Mass Transfer, 26, 1019-1028. https://doi.org/10.1016/S0735-1933(99)00091-3

  9. 9. Ghia, U., Ghia, K.N. and Shin, C.T. (1982) High-Resolutions for Incompressible Flow Using the Navier-Stokes Equations and a Multi-Grid Method. Journal of Computational Physics, 48, 387-411. https://doi.org/10.1016/0021-9991(82)90058-4

  10. 10. Moallemi, M.K. and Jang, K.S. (1992) Prandtl Number Effects on Laminar Mixed Convection Heat Transfer in a Lid-Driven Cavity. International Journal of Heat and Mass Transfer, 35, 1881-1892. https://doi.org/10.1016/0017-9310(92)90191-T

  11. 11. Hakan, F. and Oztop, I.D. (2004) Mixed Convection in Two-Sided Lid Driven Differentially Heated Square Cavity. International Journal of Heat and Mass Transfer, 47, 1761-1769. https://doi.org/10.1016/j.ijheatmasstransfer.2003.10.016

  12. 12. Chamkha, A.J. (2002) Hydro-Magnetic Combined Convection Flow in a Vertical Lid-Driven Cavity with Internal Heat Generation or Absorption. Numerical Heat Transfer, Part A: Applications, 41, 529-546. https://doi.org/10.1080/104077802753570356

  13. 13. Hussain, S. (2017) Effects of Inclination Angle on Mixed Convective Nanofluid Flow in a Double Lid-Driven Cavity with Discrete Heat Sources. International Journal of Heat and Mass Transfer, 106, 847-860. https://doi.org/10.1016/j.ijheatmasstransfer.2016.10.016

  14. 14. Sivasankaran, V.S. (2013) Numerical Study on Mixed Convection in an Inclined Lid-Driven Cavity with Discrete Heating. International Communications in Heat and Mass Transfer, 46, 112-125. https://doi.org/10.1016/j.icheatmasstransfer.2013.05.022

  15. 15. Malik, A.N. (2016) A Comparative Study of Mixed Convection and Its Effects on Partially Active Thermal Zones in a Two Sided Lid-Driven Cavity Filled with Nanofluid. Engineering Science and Technology, an International Journal, 19, 1283-1298. https://doi.org/10.1016/j.jestch.2016.02.008

  16. 16. Adair, M.J. (2015) Developing an Understanding of the Steps Involved in Solving Navier-Stokes Equations. The Mathematica Journal, 17, 1-19. https://doi.org/10.3888/tmj.17-8

  17. 17. Sharif, M.A.R. (2007) Laminar Mixed Convection in Shallow Inclined Driven Cavities with Hot Moving Lid on Top and Cooled from Bottom. Applied Thermal Engineering, 27, 1036-1042. https://doi.org/10.1016/j.applthermaleng.2006.07.035