Journal of Biomaterials and Nanobiotechnology
Vol.07 No.01(2016), Article ID:62636,10 pages
10.4236/jbnb.2016.71006

Feasibility of a Chronic Foreign Body Infection Model Studying the Influence of TiO2 Nanotube Layers on Bacterial Contamination

Charles Vorilhon1, Christophe Massard2, Vincent Raspal2, Yves Sibaud2, Christiane Forestier3, Nicolas Charbonnel3, Stéphane Descamps2,4, Komla Oscar Awitor2

1Department of Cardiology, Clermont-Ferrand University Hospital, Clermont-Ferrand, France

2C-BIOSENSS Laboratory EA 4676, Clermont-Ferrand University, Clermont-Ferrand, France

3Laboratory Microorganism UMR 6023, Clermont-Ferrand University, Clermont-Ferrand, France

4Department of Orthopedic Surgery, Clermont-Ferrand University Hospital, Clermont-Ferrand, France

Copyright © 2016 by authors and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY).

http://creativecommons.org/licenses/by/4.0/

Received 31 August 2015; accepted 8 January 2016; published 11 January 2016

ABSTRACT

Bacterial infections on the surface of medical devices are a significant problem in therapeutic approach, especially when implants are used in the living. In cardiology, pacemaker generator pocket surfaces, made in titanium alloy can be colonized by pathogen microorganism. This contamination represents a major risk of sepsis, endocarditis and localized infections for patients. A way to limit this bacterial contamination is to modify the surface topography using nano-structuration process of the titanium alloy surface of the implanted devices. The aim of this study is to evaluate the influence of TiO2 nanotube layers on bacterial infection in the living, considering the feasibility of an animal model of chronic foreign body infection. TiO2 nanotube layers prepared by electrochemical anodization of Ti foil in 0.4 wt% hydrofluoric acid solution were implanted subcutaneously in Wistar rats. Three weeks after implantation, TiO2 implants were contaminated by a Staphylococcus epidermilis strain using two different concentrations at 106 and 108 colony forming unit (CFU) in order to induce a sufficient infection level and to avoid unwanted over infection consequences on rats health during the experiments. After 28 days in the living, 75% of nanotube layers initially submitted to the 108 CFU inoculum were contaminated while only 25% nanotube layers initially submitted to the 106 CFU inoculum remained infected. This significant result underlines the influence of TiO2 nanotube layers in decreasing the infection level. Our in vitro experiments showed that the synthesized TiO2 nanotubes indeed decreased the Staphylcoccus epidermis adhesion compared to unanodized Ti foil.

Keywords:

Titanium Implants, Titanium Dioxide Nanotubes, Bacterial Adhesion, Cardiac Device Implantable

1. Introduction

Due to the evolution of medical indications, we are witnessing a cardiac device implantable (CDI) increase estimated in France at 2 percent per year [1] [2] . Infections due to contamination of CDI are relatively common and dangerous. The incidence varies between 0.13 and 19.9 percent depending on the series [3] . We distinguish localized infections at the pulse generator pocket which are the most frequent (89 percent), sepsis or endocarditis infectious, less frequent but more severe with a mortality rate around 25 percent. The majority of infections are caused by staphylococci (71 to 93.5 percent) with 33 to 75 percent of coagulase-negative Staphylococci strain and 14 to 44 percent of Staphylococci aureus. For this last specific strain, 15 to 30 percent are methicillin-resistant. Retrospective studies on the management of these infections have shown the superiority in terms of morbidity- mortality rate of an association of antibiotics and extraction of the entire CDI (pulse generator and probes) versus antibiotics alone. Indeed, in contact with the cardiac device, these bacteria create in the early hours a biofilm, increasing antibiotic resistance and mechanisms of host and can also cause chronic infection [4] . The synergistic multiple antibiotics are binding, toxic and ineffective. The extraction of CDI is complex and risky [5] .

Pulse generator is composed of a titanium alloy: Ti-6Al-4V. It has a high corrosion resistance, high biological inertia and good tissue integration (good biocompatibility). These characteristics are superior to those of pure titanium [6] . Pure titanium or titanium alloy can be nanostructured using electrochemical techniques such as anodization. It is then possible to obtain titanium dioxide nanotube arrays of controlled and homogeneous size distribution [7] -[10] . Previous studies have demonstrated an antibacterial effect, usually by reducing bacterial adhesion, but also bactericidal effect of titanium dioxide nanotube arrays [11] . In order to decrease CDI infections by using a method of nanostructuration of the device, it is necessary to confirm that the in vitro data can be extended to an in vivo animal model.

The main objective of our study was to investigate the feasibility of a chronic foreign body infection animal model and to qualify the influence of titanium dioxide nanotube arrays in decreasing the adhesion of S. epidermidis in vitro.

2. Materials and Methods

2.1. TiO2 Nanotubes Layer Synthesis

To fabricate anodic TiO2 nanotube layers, we used Ti foil (Goodfellow, 99.6% purity) with a thickness of 0.025 mm. The Ti foils were cut 8 mm × 8 mm squares by shear and degreased by successive sonication in trichloroethylene, acetone, and methanol, followed by rinsing with deionized water and blown dry with nitrogen. Afterward, the cleaned Ti samples were etched with a HF:HNO3:HCl:H2O (1:10:20:69) solution for 5 min to remove the naturally occurring oxide layer and subsequently rinsed with deionized water and blown dry with nitrogen gas. Finally, the Ti foils were dried in an oven at 100˚C and cooled in a desiccator. Anodization was carried out at room temperature (20˚C) in 0.4 wt% HF aqueous solution with the anodizing voltage maintained at 20 V during 20 min. After the anodization process, the samples were cleaned with deionized water and blown dry with nitrogen. They were finally dried in an oven at 100˚C and cooled in a desiccator.

2.2. Scanning Electron Microscopy

Samples were characterized by a Field Emission Scanning Electron Microscope (FESEM) ZEISS Supra 55 VP (ZEISS-Germany) used with a low voltage (3 kV) to limit charge effects. The working distance was 5 mm. Pictures were obtained with the secondary electron detector in-lens.

2.3. Bacterial Culture

An American Type Culture Collection (ATCC) 35,984 Staphyloccocus epidermidis strain is used. This strain was previously modified with the introduction of a plasmid carrying the gene for tetracycline resistance and that encoding a fluorescent protein (GFP) (pCN40-Δerm-Tet-GFP). The strain is stored at −80˚C.

2.4. Assay for in Vivo Study

The study was approved by the Ethics Committee for Animal Experimentation Auvergne (CEMEAA, authorization number EC 19-13). An animal model previously described [12] and already used on rats [13] was chosen with some modifications. Male Wistar rats (Janvier, Mayenne, France) from 220 to 240 g weight were used. Rats were anesthetized by intraperitoneal injections of ketamine (50 mg/kg, Panpharma, France) with Xylazine (15 mg/kg, Rumpun®, Bayer, France). During the whole experiment they receive analgesia if needed by Buprenorphine (0.05 mg/kg, Vetergesic® multidose, Alstoe, UK). For simple anesthesia for subcutaneous punctures, they receive isoflurane (2% - 3% Forane®, Baxter, USA). The rats were sacrificed by intra cardiac injection of thiopental (50 mg/kg, Rotexmedica/Panpharma, France). We implanted subcutaneously for each rats 2 multi perforated tubes of polytetrafluoroethylene (Teflon) closed at the ends and having the dimensions: 10 mm in inner diameter, 12 mm in outer diameter and 32 mm long (Figure 1). These tubes contain two Ti samples of the same nature and the same origin (either native or TiO2 nanotube arrays). A sample is for making a quantitative analysis and a second for a qualitative analysis by fluorescence. Each rat has a tube containing TiO2 nanotube arrays and a tube containing native Ti foils, thereby forming its own control. Three weeks after implantation of tubes in sterile condition of 4 rats, a puncture of the tubes is carried out to verify sterility. Animals with contaminated tubes are excluded. Four tubes (2 rats) are infected with 106 CFU (inoculum “low”) and the other 4 tubes with CFU 108 (inoculum “high”), by subcutaneous injection.

The kinetic profile of the planktonic infection (non-adherent bacteria) of the tubes is determined by performing sampling every 4 days until day 20 (Figure 2). Two hundred microliters of the fluid from the tubes are removed at each sampling. Decimal dilutions of the samples are made in saline, and then 25 µL are plated on LB agar containing tetracycline at 12 µg/mL. After 48 h incubation at 37˚C, a quantification of bacterial colonies is done.

After 28 days, the two samples are removed from each tube (Figure 3). The number of adherent bacteria (bacteria of the corresponding biofilm) of each sample is determined as described below (in vitro study). The second sample is analyzed qualitatively, using a confocal microscope (Leica TCS-LSI Solsm, Germany).

2.5. Assay for in Vitro Study and Bacterial Adhesion

Twelve nanostructured samples and 12 pure Ti plates are disposed in wells of a 24 well plate (Falcon®, BD Biosciences, California, USA) containing 1 mL of TSB (Formula per liter: Pancreatic digest of casein, 17.0 g, Papaic digest of soybean, 3.0 g, Dextrose, 2.5 g, Sodium chloride, 5.0 g, pH 7.3) and 0.5 mL of the inoculum suspension (S. epidermidis), containing about 5.106 CFU. Suspensions are incubated at (37˚C, 5% CO2, humidi- fied environment), under stirring at 25 rpm. Different incubation times are predefined: 1, 2, 6, 24 hours. At the end of incubation time, 3 plates of each assay are rinsed two times in physiological saline to remove non-adhe- rent bacteria. Each plate is sonicated for 15 min in 1.5 mL of physiological saline to detach and individualize adherent bacteria. Fifty microliters of the suspension thus created are then seeded (EasySpiral® Dilute, Interscience, Yvelines, France) onto agar plates of lysogeny Broth (LB; DifcoTM LB Agar Miller, Becton Dickinson

Figure 1. Photograph of a multi perforated Teflon tube containing nanostructured Ti foil.

Figure 2. Schematic representation of the tubes distribution contain- ing Ti foils (native or nanostructured) with S. epidermidis (planktonic and biofilm).

Figure 3. General scheme of the experiment steps (a) stalling. (b) Implantation of the two tubes containing respectively native or nano- structured Ti foils (c) wound healing, formation of serous fluid in the tubes. (d) Staphylococcus epidermidis inoculation to sterile tubes in rats (e) sampling in the tubes every 4 days for bacteriological analysis of the planktonic phase (f) euthanasia of rats. Extraction of the plates contained in the tubes for bacteriological analysis of biofilm.

and Comany Sparks, MD 21152, USA) containing Tétracycline at 12 µg/mL. These agar plates were incubated for 24 h at 37˚C. The quantification is done automatically by counting colonies (Scan® 300, Interscience, Yvelines, France). This experiment was performed in triplicate.

2.6. Statistic Study

Numerical data were analyzed using analysis of variance (ANOVA) standard as the Student test for paired samples. Indeed, we studied bacterial quantification (quantitative variable) depending on the nature of titanium surface (qualitative variable). In addition, for each incubation of a TiO2 nanotube arrays is included in the same conditions, a control sample of pure Ti. The number n is 9, so we have a degree of freedom of 8. The significant difference is seen as p < 0.05.

3. Result and Discussion

3.1. Fabrication of Ordered Nanotube Arrays

Figure 4 shows FESEM top down images of the ordered array of TiO2 nanotubes obtained by anodizing a Ti foil at 15 V (Figure 4(a)) and at 20 V (Figure 4(b)). We observe ordered nanotube arrays grown on top of the Ti foil.

From the FESEM images, measurements of the diameter and length of the TiO2 nanotubes were done. The results are shown in Table 1. The increase in the anodization voltage induces a rise of the length and diameter of the TiO2 nanotubes.

Figure 5 shows the EDX spectra of the samples anodized at 15V (Figure 5(a)) and 20 V (Figure 5(b)) and their elemental composition. The both samples had similar elemental composition. The fluorine detected on the surface of the TiO2 nanotube layers are originated from residual electrolyte in the TiO2 nanotubes.

3.2. Quantitative Results of Bacterial Adhesion

Rats are normally fed, they all continued to gain weight throughout the experiment (average weight 405 g on day 28, with minimum weight and maximum weight respectively 392 g and 419 g. We did not notice any post-operative healing problem. The two inocula used were sufficient to ensure a localized infection without altering the rats health during the experiment. After 28 days post inoculation surveillance, no rat died prematurely or had clinical signs of sepsis. Planktonic bacterial profile during the experiment is summarized in Figure 6. We have plotted Log10 (CFU/mL) versus days after the sample contamination.

With both inocula (“low” and “high”), we see a decrease in the number of bacteria over time. At the end of the experiment on day 28, a tendency to the disappearance of planktonic bacteria was observed with the inoculum

Figure 4. Top down FESEM images of TiO2 nanotube arrays nanotubes obtained by anodization at 15 V (a) and at 20 V (b), magnification 100 K.

(a) (b)

Figure 5. EDX spectra and TiO2 nanotube arrays nanotubes obtained at 15 V (a) and at 20 V (b). Abbreviation: EDX, energie dispersive X-ray.

Table 1. Influence of the anodization voltage on the length and diameter of the TiO2 nanotubes.

(a) (b)

Figure 6. Planktonic bacterial profile during the experiment: (a) Inoculum “low” at 106 CFU/mL (N = 4 light blue and mean dark blue); (b) Inoculum “high” at 108 CFU/mL (N = 4 dark red and mean light red).

“low”: in three out of four tubes, we did not detect bacteria. On the contrary, with the inoculum “high” we find bacteria in three out of four tubes (75%).

Analysis of adherent bacteria to the samples (the biofilm forming) confirms the results of plank tonic bacteria. It is summarized in Table 2.

A decrease in the amount of adherent bacteria in relation to the amount of bacteria in planktonic phase is observed when the tubes contained TiO2 nanotube arrays (Table 2) while the tubes with native Ti foils have the same amounts of adherent bacteria and planktonic bacteria.

3.3. In Vitro Bacterial Adhesion

Bacterial on growth on TiO2 nanotube compared with native Ti, depending on the incubation time is shown in Figure 7. Globally, the amount of adherent bacteria increases with time in every condition. At each time of culture, numbers of alive bacteria able to form colonies are lower in TiO2 nanotubes condition, with significate difference after 1 and 6 hours. The tendency seems to decrease later.

3.4. Discussion

This study is, for our knowledge, the first to investigate the feasibility of in vivo evaluation of the antibacterial properties of TiO2 nanotube arrays. The results of in vitro manipulations have revealed a decrease in the adhesion of S. epidermidis in the presence of TiO2 nanotube arrays.

In a previous study [14] , a decrease in bacterial adherence was observed when Titanium substrate was coated by evaporation technique using an electron beam. In contrast, when the anodization process was used, there was, in spite of a higher adhesion of fibronectin, an increase in bacterial adhesion to the TiO2 nanotube arrays. We can suggest two explanations: first, the role of fluorine coming from the electrolyte. Even if the fluorine allows a reduction in percentage living bacteria with a clean anti-bacterial effect, it helps to increase the adhesion of dead bacteria, promoting themselves the adhesion of living bacteria [15] . Secondly, anodization provides an amorphous TiO2 layer which, in comparison with a crystalline layer increases bacterial adhesion. We chose the anodizing process because this technique allows the formation of TiO2 nanotube arrays. In further works, the nanocavities may be used as nanocarrier for drug delivery.

Figure 7. Bacterial on growth on native Ti vs. TiO2 nanotube arrays.

Table 2. Planktonic and adherent bacteria quantification on day 28.

Thus, our experimental results are opposite to others studies which revealed an increase in bacteria (even living) vs native Ti. Anodization process parameters are responsible for theses changes in bacterial adhesion. In other study, higher concentration of HF (1.5% vs 0.4%), and a shorter duration of anodization (10 min vs 20 min) are used, it increases the content of fluorine ion and reduce the size of the tube diameter (70 vs 84 nm), which are two factors that promote bacterial attachment.

Concerning the nanotube diameter influence on cell adhesion, a previous study [16] showed that depending on the diameter of the TiO2 nanotube arrays, an adherence decrease for S. epidermidis and S. aureus were found. As in our work, it has been found a reduction of adhesion from H1, especially when the nanotube diameter was between 60 and 80 nm. The nanotubes would lead to a stress response of bacterial, with membrane rupture, thus reducing the number of living bacteria. For diameters of 80 nm, a 20 V voltage anodization was needed for 20 minutes with 0.4% HF, whereas for the diameters of 60 nm, a voltage of 15 V was enough. The voltage variation also causes a variation of the Ti/O ratio as regards the composition of the TiO2 nanotube arrays. This Ti/O ratio can influence the cell adhesion.

In the same study [16] , the authors found a decrease in the adhesion of dead bacteria when TiO2 nanotube arrays were annealed at high temperature (500˚C). Indeed, this technique can remove fluoride ions coming from the anodization and make the TiO2 layer crystallized. Also, it was shown that a crystalline layer decreased bacterial growth [17] . We chose initially not to anneal our nanostructured samples.

TiO2 nanotube arrays coupled or not to an electrical stimulation of 15 to 30 V also permit a decrease in the formation of the biofilm of S. aureus after 2 days of culture compared with the native Titanium [18] . Like in our study, bacterial adhesion without stimulation H24 was almost identical between the TiO2 nanotube arrays and the native Titanium. On the other side, authors noted an increase of the bacterial biomass to H1, H4 and H8 in the presence of TiO2 nanotube arrays, measured by the crystal violet staining. However, the authors could not clarify whether this was an increase in adhesion (due to overproduction of the fibronectin promoted by the TiO2 nanotube arrays), or an increase in the amount of biofilm, or both. The technique used did not distinguish between live and dead bacteria. They specified that a cell count (live bacteria) was necessary to make sense of things considering the increase in density of staining. Our study (using the determination of the number of viable bacteria, CFU) told us that bacterial adhesion to H1 and H6 was lower on TiO2 nanotube arrays.

In order to reduce bacterial adhesion, other studies have been conducted. Impregnating TiO2 nanotube arrays with antibiotic (Gentamycin), could also decrease the adherence of S. epidermidis [19] . The authors also found an increase in the adhesion of S. epidermidis to H1 on TiO2 nanotube arrays without antibiotics vs. conventional Ti, whereas for H4 there was a decrease.

More recently, the idea of incorporating silver nanoparticles into the TiO2 nanotube arrays was developed [11] . After 4 days of culture, all planktonic bacteria had been destroyed, and that this association nanoparticles and nanotubes prevent bacterial adhesion. In our study, we did not choose to use these alternative techniques. These experimental data will also have to be check in vivo.

We conducted our manipulations on sheets of Ti Goodfellow® brand, which is―as we have seen―similar to native Ti. X-ray study of a PM has shown that it was not native Ti. The material used is an alloy of Ti:Ti-6Al- 4V. Other studies focusing directly on the evaluation of in vitro antibacterial properties of the alloy TiO2 nanotube arrays had reached the same conclusions as for the TiO2 nanotube arrays obtained from pure Titanium. So we could extrapolate our results on Ti Goodfellow® sheets to those we could get on the surface of a real Pacemaker.

Considering our in vitro results, the feasibility of an animal model of chronic foreign body infection had all his senses to find a possible reduction in the adhesion of S. epidermidis on TiO2 nanotube arrays versus native Ti in vivo.

We chose an experimental model, first described in guinea pig, which was initially developed to evaluate the effectiveness of antibiotics in localized chronic foreign body infection. Contrary to the rat, this animal is similar to humans in how to resist to infection, but it is also very fragile, more expensive and difficult to handle.

For these reasons we decided to adapt this model in rats as previously described with the idea that the infected polytetrafluoroethylene tube could accept a Titanium foil in an infected environment. This is a quiet convenient method because a biofilm can develop easily on the material surface, and the surrounding planktonic phase is always accessible transcutaneously to monitor the evolution of infection. At the same time, with this model it is difficult to insure the development of a chronic infection as the inoculum quantity necessary to do that is not known and is probably strain related. We found that the introduction of Ti foil (whether native or nanostructured) into tubes were well tolerated by rats. The wound indeed, healed normalyand there were no clinical signs of poor tolerance of the foreign body. In addition, it was necessary to determine the “ideal” inoculum. It must be sufficient to induce a chronic infection in the tube, but it must also not be too large to avoid the risk of inducing sepsis, which may skew the results. Previous trials using this model had consistently confirmed this preliminary study. We chose two inocula: a “low” CFU 106 and a “high” CFU 108. This choice was guided by the fact that the rat’s natural defenses against staphylococci are more effective than those of the guinea pig and also because we used a strain of S. epidermidis not a S. aureus strain, known to be more resistant to the natural defenses of the rat. The injection of a volume of 100 µL was intended not to create pressure inside the tube that can induce capillary damage and also not to disseminate the inoculum outside the tubes. The results of this in vivo study have shown that chronic infection localized foreign body was feasible in 75% of cases, with a “high” inoculum CFU 108. The results at Day 28 were also encouraging. Indeed, when we compared the amount of planktonic and adherent bacteria, we found that they were identical in tubes containing native Ti foils, and different for those with TiO2 nanotube arrays. The amounts of adherent bacteria were then lower than those determined in planktonic phase. These results should be confirmed by a study with a sufficient number of rats to determine whether or not there is a significant difference between the two types of support.

4. Conclusion

The feasibility of a chronic foreign body infection model has been investigated in this work. The animal experiments results on wistar rats indicate that infection is still present 28 days after the samples contamination in a quarter of the implants infected at 106 CFU while 75% of the samples infected remain infected with an inoculum at 108 CFU. The adaptation of this previously described animal model of chronic foreign body infection to a new one, where the tube is considered as a cell dedicated to test infection of different materials seems to make sense. The final infection at day 28 seems to be dose-dependent. With both inocula, the number of bacteria decreases versus time, showing the tendency of the TiO2 nanotubes layer in reducing the infection more efficiently than pure titanium surface. By comparison of confocal cliché we emit the hypothesis that bacterial adhesion is lower on the nanostructured samples versus the unanodized foil. This difference concerning biofilm adhesion is confirmed by our in vitro experiments. A significant difference in bacterial adhesion is seen between native titanium foil and TiO2 nanotube arrays using the analysis of variance: bacterial adhesion is lower on nanostructured samples compared to unanodized titanium surfaces.

Acknowledgements

The authors thank Mr. Aurélien MULLIEZ for the statistical studies.

Cite this paper

CharlesVorilhon,ChristopheMassard,VincentRaspal,YvesSibaud,ChristianeForestier,NicolasCharbonnel,StéphaneDescamps,Komla OscarAwitor, (2016) Feasibility of a Chronic Foreign Body Infection Model Studying the Influence of TiO2 Nanotube Layers on Bacterial Contamination. Journal of Biomaterials and Nanobiotechnology,07,45-54. doi: 10.4236/jbnb.2016.71006

References

  1. 1. Health High Authority (2009) Advice on Implantable Cardiac Pacemakers Single and Double. CEPP.

  2. 2. Health High Authority (2007) Automatic Implantable Cardiac Defibrillators. CEPP.

  3. 3. Sohail, M.R., Uslan, D.Z., Khan, A.H., et al. (2007) Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections. Journal of the American College of Cardiology, 49, 1851-1859.
    http://dx.doi.org/10.1016/j.jacc.2007.01.072

  4. 4. Baddour, L.M., Bettmann, M.A., Bolger, A.F. (2003) Nonvalvular Cardiovascular Device-Related Infections. Circulation, 108, 2015-2031.
    http://dx.doi.org/10.1161/01.CIR.0000093201.57771.47

  5. 5. Klug, D., Lacroix, D., Savoye, C., et al. (1997) Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management. Circulation, 95, 2098-2107.
    http://dx.doi.org/10.1161/01.CIR.95.8.2098

  6. 6. Niinomi, M. (2008) Mechanical Biocompatibilities of Titanium Alloys for Biomedical Applications. Journal of the Mechanical Behavior of Biomedical Materials, 1, 30-42.
    http://dx.doi.org/10.1016/j.jmbbm.2007.07.001

  7. 7. Mor, G.K., Varghese, O.K., Paulose, M., et al. (2003) Fabrication of Tapered, Conical-Shaped Titania Nanotubes. Journal of Materials Research, 18, 2588-2593.
    http://dx.doi.org/10.1557/JMR.2003.0362

  8. 8. Descamps, S., Awitor, K.O., Raspal, V., Johnson, M.B., Bokalawela, R.S.P., Larson, P.R. and Doiron, C.F. (2013) Mechanical Properties of Nanotextured Titanium Orthopedic Screws for Clinical Applications. Journal of Medical Devices, 7, Article ID: 021005.
    http://dx.doi.org/10.1115/1.4023705

  9. 9. Jang, I., Shim, S.C., Choi, D.S., Cha, B.K., Lee, J.K., Choe, B.H. and Choi, W.Y. (2015) Effect of TiO2 Nanotubes Arrays on Osseointegration of Orthodontic Miniscrew. Biomed Microdevices, 17, 76.
    http://dx.doi.org/10.1007/s10544-015-9986-1

  10. 10. Huang, J., Tan, X., Yu, T., Zhao, L. and Liu, H. (2015) Enhanced Photovoltaic and Photoelectrocatalytic Properties by Free-Standing TiO2 Nanotubes via Anodization. Journal of Solid State Electrochemistry, 19, 1151-1160.
    http://dx.doi.org/10.1007/s10008-014-2699-1

  11. 11. Zhao, L., Wang, H., Huo, K., Cui, L., Zhang, W., Ni, H., Zhang, Y., Wu, Z. and Chu, P.K. (2011) Antibacterial Nano-Structured Titania Coating Incorporated with Silver Nanoparticles. Biomaterials, 32, 5706-5716.
    http://dx.doi.org/10.1016/j.biomaterials.2011.04.040

  12. 12. Zimmerli, W., Waldvogel, F.A., Vaudaux, P. and Nydegger, U.E. (1982) Pathogenesis of Foreign Body Infection: Description and Characteristics of an Animal Model. Journal of Infectious Diseases, 146, 487-497.
    http://dx.doi.org/10.1093/infdis/146.4.487

  13. 13. Lucet, J.C., Herrmann, M., Rohner, P., Auckenthaler, R., Waldvogel, F.A. and Lew, D.P. (1990) Treatment of Experimental Foreign Body Infection Caused by Methicillin-Resistant Staphylococcus aureus. Antimicrobial Agents and Chemotherapy, 34, 2312-2317.
    http://dx.doi.org/10.1128/AAC.34.12.2312

  14. 14. Puckett, S.D., Taylor, E., Raimondo, T. and Webster, T.J. (2010) The Relationship between the Nanostructure of Titanium Surfaces and Bacterial Attachment. Biomaterials, 31, 706-713.
    http://dx.doi.org/10.1016/j.biomaterials.2009.09.081

  15. 15. Arenas, M., Pérez-Jorge, C., Conde, A., Matykina, E., Hernández-López, J., Pérez-Tanoira, R., De Damborenea, J., Gómez-Barrena, E. and Esteba, J. (2013) Doped TiO2 Anodic Layers of Enhanced Antibacterial Properties. Colloids and Surfaces B: Biointerfaces, 105, 106-112.
    http://dx.doi.org/10.1016/j.colsurfb.2012.12.051

  16. 16. Ercan, B., Taylor, E., Alpaslan, E. and Webster, T.J. (2011) Diameter of Titanium Nanotubes Influences Anti-Bacterial Efficacy. Nanotechnology, 22, Article ID: 295102.
    http://dx.doi.org/10.1088/0957-4484/22/29/295102

  17. 17. Del Curto, B., Brunella, M., Giordano, C., Pedeferri, M., Valtulina, V., Visai, V. and Cigada, A. (2005) Decreased Bacterial Adhesion to Surface-Treated Titanium. The International Journal of Artificial Organs, 28, 718-730.

  18. 18. Ercan, B., Kummer, K.M., Tarquinio, K.M. and Webster, T.J. (2011) Decreased Staphylococcus aureus Biofilm Growth on Anodized Nanotubular Titanium and the Effect of Electrical Stimulation. Acta Biomaterialia, 7, 3003.
    http://dx.doi.org/10.1016/j.actbio.2011.04.002

  19. 19. Popat, K.C., Eltgroth, M., Latempa, T.J., Grimes, C.A. and Desai, T.A. (2007) Decreased Staphylococcus epidermis Adhesion and Increased Osteoblast Functionality on Antibiotic-Loaded Titania Nanotubes. Biomaterials, 28, 4880-4888.
    http://dx.doi.org/10.1016/j.biomaterials.2007.07.037