American Journal of Analytical Chemistry
Vol.06 No.02(2015), Article ID:53300,12 pages
10.4236/ajac.2015.62008

Development and Validation of Stability Indicating HPTLC Assay for Determination of Gemifloxacin Mesylate in Dosage Forms

Ashraf M. Mahmoud1,2*, Noha N. Atia1, Salwa R. El-Shabouri1, Wesam M. El-Koussi1

1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut, Egypt

2Department of Pharmaceutical Chemistry, College of Pharmacy, Najran University, Najran, KSA

Email: *a.mahmoud2007@yahoo.com

Copyright © 2015 by authors and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY).

http://creativecommons.org/licenses/by/4.0/

Received 4 December 2014; accepted 8 January 2015; published 16 January 2015

ABSTRACT

Simple and sensitive stability-indicating high performance thin layer chromatography (HPTLC) assay was developed and validated for quantitative determination of the antibacterial drug, gemifloxacin mesylate (GFX) in presence of its degradation products and ambroxol hydrochloride. The chromatographic separation was performed on HPTLC precoated silica gel plate 60F254 as stationary phase. The mobile phase consisted of a mixture of ethyl acetate: methanol: 25% ammonia, (8:4.5:3, v/v/v). The detection was performed using fluorescence mode and the emission intensity was measured using optical filter K400 after excitation at 342 nm. The Rf value for GFX was 0.47 ± 0.03. Good correlation coefficient was obtained over the concentration range of 1.5 - 180 ng/band. The LOD and LOQ of the proposed method were 0.28 and 0.86 ng/band, respectively. The proposed method was successfully applied for the analysis of GFX in its single and combined dosage forms. Moreover, it was utilized to investigate the kinetics of acidic, alkaline, neutral, oxidative and photolytic degradation of the drug. The apparent kinetic-order rate constants and half-life times of the degradation process were calculated. Furthermore, the proposed method was successfully applied for investigating the factors affecting the storage of GFX.

Keywords:

HPTLC, Gemifloxacin Mesylate, Stability Indicating Assay, Kinetics, Degradation, Pharmaceutical Preparations

1. Introduction

The inherent stability characteristics of a drug should be established using stress studies on the parent drug according to the stability test ICH guideline Q1A (R2) [1] . Besides, the intrinsic stability and kinetic studies are the fundamental elements in the search for possible degradation products of drugs; however, these products do not commonly appear under normal drug storage conditions. High performance thin-layer chromatography (HPTLC) has been widely used in the pharmaceutical analysis as stability-indicating assay [2] , and for clinical pharmacokinetic studies [3] . The analysis in these areas usually involves measurement of very low concentrations of drugs and/or degradation products which can be detected by HPTLC in nanogram and picogram levels in absorbance and fluorescence based measurements, respectively. The importance and widespread of HPTLC in pharmaceutical analysis are attributed to their inherent selectivity, high sensitivity, sustainability and low operating costs. Moreover, its use in the developing countries will greatly help them in identifying the counterfeit and sub-stand- ard pharmaceutical products in their markets, where the WHO has identified this illegal distribution as a major problem in the developing countries [4] .

Gemifloxacin mesylate (GFX, Figure 1) is a recently developed fluoroquinolone antibacterial compound with a broad spectrum activity. It acts through the formation of a ternary complex with both DNA gyrase and topoisomerase IV which are responsible for the blockade of DNA replication and transcription [5] [6] . Thus, it has an excellent in vitro and in vivo efficacy with good pharmacokinetic profile [7] . Nowadays, GFX is commonly used for treatment of community acquired pneumonia and acute bacterial exacerbation of chronic bronchitis that provide high rates of mortality worldwide [7] .

GFX is not yet the subject of a monograph in any pharmacopoeia. Reviewing the literature revealed that, several analytical methods were reported for determination of GFX in its pharmaceutical preparations or human plasma by spectrofluorometrically [8] , LC-MS-MS [9] , HPLC [10] and HPTLC [11] - [13] . But, the literature is still lacking the analytical procedures based on kinetic study that describe the stability of GFX under different stress conditions. Whereas, most of the reported stability indicating assays [13] - [18] did not provide a complete discussion about the behavior of GFX at different time intervals. Moreover, the kinetic studies of GFX were restricted on one method that describes the kinetic of GFX after its photo-degradation only [19] .

Therefore, the aim of the present study is the development of the first stability-indicating HPTLC assay using fluorescence detection for determination of GFX in dosage forms. In addition, it used for studying the inherent stability of GFX under different stress conditions according to ICH guidelines [1] . The present study also includes the investigation of degradation kinetics and the kinetics run parameters under different degradation stress conditions. Moreover, different factors that affect the stability of GFX have been studied.

2. Experimental

2.1. Materials

Analytically pure GFX (99.8%) was provided from Tabuk Pharmaceutical Manufacturing Co., KSA and used as received without further purifications. Ambroxol HCl (AMB) was obtained from Galaxo Wellcome, S.A.E., El Salam City, Cairo, Egypt. The pharmaceutical dosage forms used in this study were; Factive® (Oscient Pharmaceuticals, USA), Floxguard® (Advocure Pharmaceuticals, Obour city, Egypt), Quinabiotic® (Medizen Pharmaceutical Industries, Alexandria, Egypt), Gemique® (Meivo International for Pharmaceutical Indusries, Alexandria, Egypt) and Gemiloxes® (Sabaa International Company for Pharmaceuticals and Chemicals, Egypt) which are labeled to contain an equivalent amount of 320 mg of gemifloxacin per tablet. Synthetic mixture was pre-

Figure 1. Chemical structure of gemifloxacin mesylate.

pared according to the dosage form “G-CIN-A” in India (Hetero Pvt. Ltd, India) which are labeled to contain 320 mg of GFX and 75 mg of ambroxol HCl per tablet. HPLC grade methanol was purchased from Sigma Aldrich, Seelze, Germany. Hydrogen peroxide (30% v/v) was obtained from Arabic Laboratory Equipment Co., Egypt. Other solvents and materials used throughout this study were of analytical grade.

2.2. Instrumentation and Chromatographic Conditions

The sample was applied with Camag microliter syringe on HPTLC precoated silica gel plate 60F254 (20 × 5 cm, 6 - 8 µm thicknesses; Merck, Darmstadt, Germany) by using Camag Linomat V applicator (Camag, Switzerland, Germany). The sample was sprayed in the form of narrow bands of 4 mm length at a constant rate 3 µl/s. Mobile phase consisted of ethyl acetate: methanol: 25% ammonia (8:4.5:3 v/v/v) was freshly prepared and used for the development step. Linear ascending development was carried out in trough glass chamber (24 cm W × 14 cm H × 9.5 cm D, standard type) (Sigma-Aldrich Co., USA) that pre-saturated with the mobile phase for at least 20 min at room temperature (25˚C ± 2˚C). The solvent front was moved about three-fourths of the length of the plate. After that, the plate was air-dried for about 5 min. The densitometric scanning was performed by using Camag TLC scanner III system equipped with Hg lamp for the fluorescence detection. Where, the scanning was performed using optical filter K400 after excitation at 342 nm. The system control and data acquisition were performed by winCATS software, version 1.4.4.6337. Quantitative evaluations were performed via peak areas. UV lamp (Vilber Lournate 220 V 50 Hz; Marne-lavallee Cedex, France) and MLV type thermostatically controlled water bath (Salvis AG Emmenbruck, Luzern, Germany) were used for the photo and aqueous degradation of GFX, respectively.

2.3. Preparation of Standard Solutions

A stock solution containing 100 μg/ml of GFX was prepared in methanol. This solution was further diluted with the same solvent to obtain a working standard solutions containing 0.5 - 60 μg/ml of GFX. The solutions were kept in the refrigerator and protected from light.

2.4. Procedure for Pharmaceutical Formulations

2.4.1. Tablets Sample Solution

Twenty tablets were weighed and finely powdered. An accurately weighed amount of the powder equivalent to 25 mg of GFX was transferred into a 100 ml calibrated flask, and dissolved in about 40 ml methanol. The contents of the flask were swirled, sonicated for 5 min, and then completed to volume with methanol. The contents were mixed well and filtered rejecting the first portion of the filtrate. Further dilution was made with methanol to obtain sample solution containing 40 µg/ml as a suitable concentration for the analysis.

2.4.2. Synthetic Mixture Preparation

An accurately weighed amount of the powder equivalent to 32 mg of GFX and 7.5 mg AMB (i.e. in the ratio of 4.3:1.0 w/w as in the combined dosage form) were transferred into a 100 ml calibrated flask. The contents were ultrasonicated for 5 min with 40 ml methanol then, the void volume was completed with the same solvent. After that, further dilution was made with methanol to obtain sample solution containing 60 µg/ml of GFX and 14.06 µg/ml of AMB as a suitable concentrations for the analysis.

2.5. Degradation Studies

2.5.1. Acidic Degradation

Ten milligrams of GFX was transferred into a series of 25 ml volumetric flasks and dissolved in 10 ml 1 M HCl. The flasks were thoroughly covered with aluminum foil, allowed to stand at room temperature (25˚C ± 2˚C) for 1, 2, 3, 4, 6, 8, 10 and 12 hr, neutralized and completed to volume with methanol. After that, further dilution with methanol was done to produce final concentration of 50 µg/ml and 3 µl from these solutions (containing 150 ng/band) corresponding to each time interval was applied in triplicate on HPTLC plate then the general procedure was followed.

2.5.2. Alkaline Degradation

The same procedure as acidic hydrolysis was employed using 0.2 M NaOH instead of 1 M HCl.

2.5.3. Oxidative Degradation

Ten milligrams of GFX was transferred into a series of 10 ml volumetric flasks and dissolved in 10 ml 30% hydrogen peroxide. The flasks were thoroughly covered with aluminum foil, allowed to stand at room temperature (25˚C ± 2˚C) for 1, 2, 3, 4, 6, 8 and 10 hr. Then, further dilution with methanol was done to produce final concentration of 50 µg/ml then the general procedure was followed.

2.5.4. Neutral (Aqueous) Hydrolysis

Ten milligrams of GFX was transferred into 10 ml volumetric flask and completed to the mark with double distilled water. The flask was heated in thermostatted water bath at 100˚C for 12 hr and aliquot was taken at different time intervals (1, 2, 3, 4, 6, 8, 10 and 12 hr) and further diluted with methanol to produce final concentration of 50 µg/ml.

2.5.5. Photolytic Degradation

Five milliliters of GFX stock solution (1 mg/ml) was transferred into a series of matched 1 cm quartz sample cells. The cells were exposed to UV radiation at a wavelength of 365 nm and at a distance of 15 cm, placed in a wooden cabinet for different time intervals (1, 2, 3, 4, 6 and 8 hr). After that, 0.5 ml of each solution was transferred into 10 ml volumetric flask and diluted with methanol to produce final concentration of 50 µg/ml. Control sample was protected from light with aluminum foil and used at the same concentration and then the general procedure was followed directly.

2.6. Stability of Standard Solution at Different Storage Conditions

The stability of GFX (50 µg/ml) in methanol was monitored under four storage conditions; in refrigerator (4˚C), at room temperature (25˚C ± 2˚C) with protection or unprotection (top-bench) from light; or under direct daylight exposure (prepared in transparent tightly capped glass tube and positioned behind closed window glass). The concentration of GFX was monitored under these conditions at different time intervals (24, 48, 72, 96, 120 and 144 hr). The change in the concentration of GFX was analyzed against freshly prepared standard solution.

3. Results and Discussion

3.1. Optimization of the Chromatographic Conditions

3.1.1. Mobile Phase

The separation of GFX could be adjusted by changing the composition of the mobile phase. Initially individual solvents like methanol, hexane, chloroform, and ethyl acetate were tested. The results showed that GFX was developed with methanol and ethyl acetate but with unsuitable Rf value. Then Different ratios of ethyl acetate and methanol were investigated. The results indicated that the best Rf value was achieved when the ratio of ethyl acetate: methanol was 8:4.5 (v/v) but tailing was observed. Several experiments have shown that the employment of an appropriate ratio of acid or base in the mobile phase may improve the chromatographic peak resolution [20] . The acidic pH of the mobile phase was also tested using either acetic or phosphoric acid and was found that they significantly reduce the fluorescence intensity and broaden the chromatographic peak. Thus, the acid was replaced with ammonia solution where different concentrations of ammonia (10%, 15%, 20%, 25% or 33%) were tested. The results showed that 25% ammonia was able to improve the shape of the chromatographic peak of GFX and resulting in more symmetric peak. Further experiments were performed and finally the optimum mobile phase was consisted of ethyl acetate: methanol: 25% ammonia, (8:4.5:3 v/v/v). Figure 2(a), shows a sharp and well-defined symmetrical peak of GFX at Rf = 0.47 ± 0.03 using the selected mobile phase system.

3.1.2. Fluorescence Detection

GFX has a native fluorescence spectrum exhibiting two excitation maxima at 272 and 342 nm and one emission at 391 nm. The fluorescence intensity obtained at λex 272 nm was more than that obtained at λex 342 nm. Thus, the first trial was performed by excitation at 272 nm and optical filter K400 but it was found that the peak of GFX was inverted. This may be due to that the HPTLC plates with fluorescence indicator (F254) absorb in wavelength range of 250 - 300 nm, resulting in fluorescence quenching [21] . So, λex 342 nm and optical filter K400 were selected in this study for direct measurement of the fluorescence intensity of GFX.

(a)(b)

Figure 2. HPTLC densitograms of GFX (150 ng/band, Rf 0.47 ± 0.03) and AMB (35 ng/band, Rf 0.72) using: (a) Fluorescence detection by optical filter K400 after excitation at 342 nm; (b) UV detection at 342 nm.

3.2. Method Validation

The method was fully validated according ICH guidelines [22] . All results were expressed as percentages, with n representing the number of values. A 5% significance level was used for evaluation.

3.2.1. Linearity, Limits of Detection and Quantitation

A calibration curve was constructed by plotting the peak area of GFX standard solutions versus different concentrations of GFX. Under the optimum conditions, linear plot (n = 6) with good correlation coefficient (0.9999) was obtained over the concentration range 1.5 - 180 ng/band. The regression equation thus obtained from calibration plots, y = 82.98x + 73.46 (where y = area obtained, x = concentration in ng/band), was used for quantitative estimation of GFX in different samples. Where, the mean values of slope and intercept were 82.98 ± 0.09 and 73.46 ± 7.11, respectively.

The limits of detection (LOD) and quantitation (LOQ) which represents the sensitivity of the proposed method were determined [22] using the formula: LOD or LOQ = kSDa/b, where κ is a numerical constant equal to 3.3 for LOD and 10 for LOQ, SDa is the standard deviation of the intercept, and b is the slope. The LOD and LOQ values were 0.28 and 0.86 ng/band, respectively which indicated the high sensitivity of the proposed method.

3.2.2. Accuracy and Precision

The accuracy of the proposed method was evaluated by determining the percentage recovery of GFX at three different concentrations covering the specified range (six replicates of each concentration). The obtained recovery results shown in Table 1 indicate the high accuracy. In addition, the small % RSD (0.67% - 2.66%) points to the good repeatability of the proposed method.

3.2.3. Robustness

Robustness was examined by evaluating the influence of deliberate small variation in the experimental conditions on the performance of the proposed method. It was found that small variation in the mobile phase ratios (±0.5 ml), ammonia concentration (±5%) and saturation time (±5 min) did not significantly affect the results indicating the reliability of the proposed method for the analysis of GFX (Table 2).

3.2.4. Selectivity

The selectivity of an assay is a measure of the extent to which the method can be used to determine a particular compound in the matrices analyzed without interference from matrix components. The selectivity herein is strongly achieved by using both the suitable mobile phase for separation and the fluorescence detector that can determine GFX without any suspicion from the interfering AMB which has no native fluorescence (Figure 2). Also, the recovery results of GFX-AMB synthetic mixture indicated the selectivity of the proposed method (Table 3).

Moreover, the selectivity of the method was extended to the ability to determine GFX in the presence of its degradation products without any interference.

Table 1. The accuracy and precision of the proposed method.

aMean of six replicates.

Table 2. Robustness of the proposed HPTLC method.

aMean of three determinations and drug concentration used 30 ng/band; bFollowing the general assay procedure conditions.

Table 3. Analysis of GFX in tablets by the proposed and reported methods.

aTheoretical values for t and F at 95% confidence limit and n = 5 were 2.31 and 6.39, respectively; bReference [11] .

3.3. Applications

The proposed method was successfully applied for determination of GFX in its single dosage form tablets or in the synthetic mixture with AMB. Five replicate analyses were performed for each dosage form and the results obtained were validated by comparison with well-established reported method [11] , by means of t-test and F-test at 95% confidence level. No significant difference was found between the two methods, indicating the high accuracy and precision of the proposed HPTLC method (Table 3).

3.4. Stability Indicating and Kinetics Studies

ICH guidelines [1] suggested that the susceptibility to acid/base hydrolysis, oxidation, and photolytic stability are required tests and consequently the ideal stability indicating method is one that quantifies the drug alone and also resolves its degradation products. Therefore, GFX was subjected to different stress conditions according to ICH recommended guidelines. The results suggested the following degradation behavior:

3.4.1. Acidic Degradation

Initially, 0.5 M HCl was used at room temperature for degradation of GFX at different time intervals but mild degradation was observed after 4 hr. Thus, the strength of acid was increased to 1 M HCl where 95.82% of GFX was remained after 1 hr. Then, the concentration of GFX was decreased gradually with time to be 11.27% after 12 hr. The developed densitogram of the degraded GFX showed well separated peak of GFX with two additional peaks at different Rf values.

It may be noteworthy that this method is not suggested to establish material balance between the extent of drug decomposition and formation of the degradation products. This may be due to that some of the products are shown to decompose further in a complex reaction scheme. Where, one peak of an acid degradation product (D1) was observed after 1 hr at Rf 0.25. Then, D1 was decreased gradually with time with the appearance of another degradant (D2) at Rf 0.13 (Figure 3(a) and Figure 3(b)). So, the acidic degradation behavior may be expressed as follow:

The kinetics of acidic degradation was also studied, through the decrease in drug concentration with time. Figure 4 indicates that the degradation process of GFX can be described by first-order reaction kinetic. From the slope of the straight line, k, and t1/2 were calculated as 0.194 hr−1 and 3.564 hr, respectively.

(a)(b)(c)

Figure 3. HPTLC densitograms of GFX (150 ng/band) at different stress conditions. (a) Pure GFX (Rf 0.47 ± 0.03); (b) Acidic; and (c) Photo-degradation conditions.

(a)(b)(c)

Figure 4. The kinetics of acidic degradation of GFX. (a) Plot of the remaining concentration (C, ng/band) of GFX versus time (hr); (b) Plot of log C versus time (hr); and (c) Plot of 1/C versus time (hr).

3.4.2. Alkaline Degradation

The degradation rate of GFX in alkali was very fast as compared to that in acid. Where, complete alkaline degradation of GFX was observed at once by using 1 M NaOH. Also, the alkaline degradation of GFX in 0.5 M NaOH was so fast that about 80% was degraded after 30 min. Then, the study was investigated in 0.2 M NaOH at room temperature, where 73.91% of GFX was still remained after 1 hr then complete drug degradation was observed after 8 hr.

It is notable that there is gradual decrease in the peak area of GFX with increasing time but without corresponding appearance of a new peak. This indicates that the drug is hydrolysed under alkaline conditions but non- fluorescent degradants were performed. Therefore, the alkaline degradation behavior may be expressed as follow:

Studying the kinetics of alkaline degradation of GFX indicated that the alkaline degradation of GFX can be described by the first-order kinetic. Then, k and t1/2 were calculated as 0.370 hr−1 and 1.873 hr, respectively.

3.4.3. Oxidative Degradation

Initial studies were used 3% H2O2 at room temperature for 6 hr. No degradation was observed at all at this concentration. Thereafter, the drug was exposed to 30% H2O2 at room temperature for a period of 10 hr. GFX was found to be nearly stable to the oxidative degradation till 2 hr then mild degradation was observed. Finally, after 10 hr, 72.98% of GFX was still remained with no appearance of any extra peaks.

The oxidative degradation kinetics was evaluated by determination of the regression coefficients. The obtained regression coefficient values were −0.9646, −0.9552 and 0.9440 for zero, first and second order kinetics, respectively. Therefore, the oxidative degradation of GFX could be better described as zero order kinetic. The obtained degradation rate constant (k) and t1/2 were: 4.036 ng hr−1 and 18.581 hr, respectively.

3.4.4. Neutral Hydrolysis

Initial studies were performed by heating aqueous solution of GFX at 40˚C or 75˚C for 6 hr. No degradation was observed under these conditions. Thereafter, the drug solution was heated at 100˚C for 12 hr. Mild degradation was observed after 2 hr and nearly 15% of GFX was degraded after 12 hr without appearance of extra peaks.

The degradation kinetics of GFX under the neutral hydrolysis was evaluated by determination of the regres- sion coefficients of the three plots which were found to be −0.9619, −0.9651 and 0.9682 for zero, first and second order plot; respectively. These results showed that the neutral hydrolysis of GFX could be better de- scribed as second order kinetic. The calculated k and t1/2 were 9.147 × 10−5 ng−1∙hr−1 and 72.883 hr, respectively.

3.4.5. Photo-Degradation

Phototoxicity is a class effect, common to all the fluoroquinolones. It appears as a result of the interaction between UVA light (320 - 400 nm) and the fluoroquinolone molecule. This interaction produces photo-degradation products and/or reactive oxygen species that may result in tissue damage [23] . Therefore, the purpose of photostability testing is to provide evidence on how the quality of a drug varies with time under the influence of light. A wavelength of 365 nm was selected herein according to reported study for GFX on the skin [24] .

The results ensured the photo-degradation of GFX at 365 nm with formation of yellow-colored solutions which increased along the exposure time. The peak area of GFX showed considerable decrease over time and nearly 15.10% of the drug was still remained after 8 hr. The photo-degradation pattern of GFX shows 6 well- separated photo-degradation products (named according to increased Rf values; D1-D6) (Figure 3(c)). Actually, the behavior of GFX showed a complex reaction scheme where, some products are shown to decompose further to other ones.

GFX photo-degradation kinetics can be described by first-order reaction kinetic. The calculated k and t1/2 were 0.214 hr−1 and 3.235 hr, respectively. These results come in concordance with the photo-degradation pattern of other fluoroquinolones those exposed to UVA and determined using HPTLC technique [25] .

3.5. Stability of Standard Solution of GFX

This study is concerned with the recommended conditions at which the drug can be exposed for a stipulated period of time and retains its stability. This is critical step for any drug to avoid the frequent errors in the quantitative analysis. Therefore, the stability of methanolic solution of GFX was tested for 144 hr, under different storage conditions. The results revealed that GFX was considered stable when stored at refrigerator and at room temperature with protection from light (Figure 5).

Unlike the above mentioned storage conditions, degradation products related to GFX were detected for the unprotected solutions and that exposed to direct daylight. In both cases, the concentration of GFX decreased during storage with the appearance of degradation products (Figure 4). It was notable that, the least stable solutions are those exposed to direct daylight which begins to be degraded significantly from the first day exposure and completely disappeared within 96 hr. While, the other solution that stored without protection from light was degraded gradually with time and nearly 27.85% of GFX was still remained after 144 hr. Thus, to preserve GFX solution from degradation, protection from light is critical.

The kinetics of GFX can be described by zero order kinetic for unprotected solutions where, the degradation rate constant (k) and t1/2 were calculated as 0.746 ng∙hr−1 and 100.48 hr, respectively. While, the solutions exposed to daylight can be expressed by first-order kinetic where, k and t1/2 were 0.055 hr−1 and 12.61 hr, respectively (Figure 6).

Noteworthy, the photo-degradation rate of GFX was higher after exposure to artificial UV light than that under daylight condition. This may be due to that, the proportion of photo-degradation may be dependent on the intensity and wavelength of radiation where the true environmental UVA exposure varies with time of day, pollution and its position to the window glass [24] . Moreover, the type of container may play a role where the ordinary glass (used in direct daylight effect) is partially transparent to UVA but quartz cell (used in UV effect at 365 nm) is highly transparent [26] .

Figure 5. 3D HPTLC-densitogram indicating the effect of different storage conditions on GFX (150 ng/band) after 144 hr: (a) Fresh solution; (b) Refrigerated solution; (c) Protected solution at room temperature; (d) Unprotected solution at room temperature; and (e) Solution exposed to direct daylight.

(a)(b)(c)

Figure 6. The kinetics of GFX hydrolysis at different storage conditions: (a) Plot of the remaining concentration (C, ng/band) of GFX versus time (hr); (b) Plot of log C versus time (hr); and (c) Plot of 1/C versus time (hr).

4. Conclusion

This work described simple, sensitive, and selective stability-indicating HPTLC assay with fluorescence detection for determination of GFX. Statistical analysis proves that the proposed method is suitable for the analysis of GFX in its single and combined dosage forms. Moreover, it was tested and validated as stability-indicating assay for determination of GFX in presence of its degradation products. It is found to be more easy, economic and less time-consuming as compared with the reported HPLC and LC-MS methods with stability-indicating property. Furthermore, it is effectively applied to study the kinetics of the degradation behavior of GFX at different stress conditions for the first time. It also provides a good pathway for the best storage conditions that can preserve GFX stable for more reproducible results. Therefore, this method is worthy recommended for routine quality control of GFX in pharmaceutical industries and research laboratories.

References

  1. ICH Guidance for Industry (Q1A) (R2) (2003) Stability Testing of New Drug Substances and Products in Federal Register. ICH Guidance for Industry, Geneva.
  2. El Zeany, B.A., Moustafa, A.A. and Farid, N.F. (2003) Determination of Zolpidem Hemitartrate by Quantitative HPTLC and LC. Journal of Pharmaceutical and Biomedical Analysis, 33, 393-401. http://dx.doi.org/10.1016/S0731-7085(03)00243-7
  3. Guermouche, M.H., Habel, D. and Guermouche, S. (1999) Assay of Tinidazole in Human Serum by High-Performance Thin-Layer Chromatography: Comparison with High-Performance Liquid Chromatography. Journal of AOAC International, 82, 244-247.
  4. Kaale, E., Risha, P. and Layloff, T. (2011) TLC for Pharmaceutical Analysis in Resource Limited Countries. Journal of Chromatography A, 1218, 2732-2736. http://dx.doi.org/10.1016/j.chroma.2010.12.022
  5. Le, T.P. and Xiong, Y.Q. (2001) Gemifloxacin. Drugs of Today, 37, 401-410. http://dx.doi.org/10.1358/dot.2001.37.6.627959
  6. Yoo, B.K., Triller, D.M., Yong, C.S. and Lodise, T.P. (2004) Gemifloxacin: A New Fluoroquinolone Approved for Treat- ment of Respiratory Infections. The Annals of Pharmacotherapy, 38, 1226-1235. http://dx.doi.org/10.1345/aph.1E003
  7. Hong, C.Y. (2001) Discovery of Gemifloxacin (Factive, LB20304a): A Quinolone of New a Generation. Il Farmaco, 56, 41-44. http://dx.doi.org/10.1016/S0014-827X(01)01017-5
  8. Atia, N.N., Mahmoud, A.M., El-Shabouri, S.R. and El-Koussi, W.M. (2013) Two Validated Spectrofluorometric Methods for Determination of Gemifloxacin Mesylate in Tablets and Human Plasma. International Journal of Analytical Chemistry, 2013, 1-11. http://dx.doi.org/10.1155/2013/137279
  9. Doyle, E., Fowles, S.E., McDonnell, D.F., McCarthy, R. and White, S.A. (2000) Rapid Determination of Gemifloxacin in Human Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry. Journal of Chromatography B: Biomedical Sciences and Applications, 746, 191-198. http://dx.doi.org/10.1016/S0378-4347(00)00333-9
  10. Al-Hadiya, B.M.H., Khady, A.A. and Mostafa, G.A.E. (2010) Validated Liquid Chromatographic-Fluorescence Method for the Quantitation of Gemifloxacin in Human Plasma. Talanta, 83, 110-116. http://dx.doi.org/10.1016/j.talanta.2010.08.047
  11. Rote, A.R. and Pingle, S.P. (2009) Reverse Phase-HPLC and HPTLC Methods for Determination of Gemifloxacin Mesylate in Human Plasma. Journal of Chromatography B, 877, 3719-3723. http://dx.doi.org/10.1016/j.jchromb.2009.08.013
  12. El-Koussi, W.M., Atia, N.N., Mahmoud, A.M. and El-Shabouri, S.R. (2014) HPTLC Method for Direct Determination of Gemifloxacin Mesylate in Human Plasma. Journal of Chromatography B, 967, 98-101. http://dx.doi.org/10.1016/j.jchromb.2014.07.004
  13. Raja, T. and Rao, A.L. (2012) Development and Validation of HPTLC Method for the Simultaneous Estimation of Gemifloxacin Mesylate and Ambroxol Hydrochloride in Bulk and Tablet Dosage Form. Analytical Chemistry Letters, 2, 152-158. http://dx.doi.org/10.1080/22297928.2000.10648263
  14. Elbashir, A., Saad, B., Ali, A.S.M., Al-Azzam, K. and Aboul-Enein, H. (2008) Validated Stability Indicating Assay of Gemifloxacin and Lomefloxacin in Tablet Formulations by Capillary Electrophoresis. Journal of Liquid Chromatography & Related Technologies, 31, 1465-1477. http://dx.doi.org/10.1080/10826070802039481
  15. Ranjane, P.N., Gandhi, S.V., Kadukar, S.S. and Bothara, K.G. (2010) Stability Indicating RP-LC Method for the Determination of Gemifloxacin Mesylate. Chromatographia, 71, 1113-1117. http://dx.doi.org/10.1365/s10337-009-1351-1
  16. Gandhimathi, N., Ravi, T.K. and Bharathi, N. (2010) Study of Hydrolytic and Oxidative Behavior of Gemifloxacin Mesylate in Aqueous Solution by LC-MS. Journal of Global Pharma Technology, 2, 81-85.
  17. Paim, C.S., Führ, F., Barth, A.B., Goncalves, C.E.I., Nardi, N., Steppe, M. and Schapoval, E.E.S. (2011) Gemifloxacin Mesylate Stability Evaluation Applying a Validated Bioassay Method and in Vitro Cytotoxic Study. Talanta, 83, 1774- 1779. http://dx.doi.org/10.1016/j.talanta.2010.11.069
  18. Nageswara Rao, R., Naidu, C.G., Prasad, K.G. and Narasimha, R. (2011) Development and Validation of a RP-HPLC Method for Stability-Indicating Assay of Gemifloxacin Mesylate Including Identification of Related Substances by LC-ESI-MS/MS, 1H and 13C NMR Spectroscopy. Biomedical Chromatography, 25, 1222-1229. http://dx.doi.org/10.1002/bmc.1594
  19. Paim, S., Fuhr, F., Miron, S., Pereira, L., Malesuik, D., Steppe, M. and Schapoval, E.S. (2010) Stability-Indicating LC Assay and Determination of System Suitability Limits with a Robustness Test of Gemifloxacin Mesylate in Tablets. Current Analytical Chemistry, 6, 269-276.
  20. Fried, B. and Sherma, J. (1999) Thin-Layer Chromatography. Vol. 81, CRC Press, Boca Raton.
  21. Fried, B. and Sherma, J. (1982) Thin Layer Chromatography. Vol. 17, Marcel Dekker, Inc., New York, 308.
  22. ICH Guidance for Industry, Q2 (R1) (2005) Validation of Analytical Procedures: Text and Methodology. Federal Register, Geneva, 1-13.
  23. Wainwright, N., Collins, P. and Ferguson, J. (1993) Photosensitivity Associated with Antibacterial Agents. Drug Safety, 9, 437-440. http://dx.doi.org/10.2165/00002018-199309060-00006
  24. Vousden, M., Ferguson, J., Richards, J., Bird, N. and Allen, A. (1999) Evaluation of Phototoxic Potential of Gemifloxacin in Healthy Volunteers Compared with Ciprofloxacin. Chemotherapy, 45, 512-520. http://dx.doi.org/10.1159/000007246
  25. Hidalgo, M.E., Pessoa, C., Fernandez, E. and Cardenas, A.M. (1993) Comparative Determination of Photodegradation Kinetics of Quinolones. Journal of Photochemistry and Photobiology A: Chemistry, 73, 135-138. http://dx.doi.org/10.1016/1010-6030(93)80042-8
  26. Endruweit, A., Johnson, M.S. and Long, A.C. (2006) Curing of Composite Components by Ultraviolet Radiation: A Review. Polymer Composites, 27, 119-128. http://dx.doi.org/10.1002/pc.20166

NOTES

*Corresponding author.