The Urine Diverting Dehydration Toilet (UDDT) is one of a wide range of technologies Ecological Sanitation (Ecosan) offers. A commonly used type is the so called solar UDDT, constructed with inclined vault doors or panels which are usually made from black iron sheets to increase the temperature inside the vaults and therefore would facilitate dehydration and hygienisation. The study aims to give recommendations on the most appropriate system by comparing solar and non-solar UDDT systems. Existing building standards for UDDTs were reviewed, 133 UDDT sites visited and a comparative temperature study of the temperature inside the vaults of different UDDT systems carried out. The temperature study needed to assess if solar UDDTs would actually succeed in raising the temperature inside the vault. Programmed temperature loggers were placed in the vaults of solar and non-solar UDDTs. The review of building standards showed that the system recommended most is the solar UDDT. The field visits identified a number of problems related to the construction of solar UDDTs. The temperature study showed that solar UDDTs do not necessarily increase the temperature inside the vault significantly and therefore are not speeding up dehydration and pathogen destruction. The study hence concludes that before a solar UDDT system is chosen the climatic conditions have to be assessed carefully. The recommended standard design should be a non-solar UDDT system. It is hoped that the study will facilitate a move towards the construction of non-solar UDDTs.
A successful sanitation system has to be hygienically safe, affordable and user friendly. The neglect of the latter characteristic is often the reason for failed sanitation projects. Hygienic safety and affordability are the main parameters for the development of different designs. The hygienic safety of the overall system has to be guaranteed. The cost has to be within the potential users means. User friendliness will assure satisfied usage. Therefore, there are different designs for each technology available. The different designs should be evaluated at regular intervals to promote the most successful ones and to avoid preventable failures and overspending. This study compares different designs of Urine Diversion Dehydration Toilets (UDDTs)―one common technology of ecological sanitation (ecosan). UDDTs can be designed as single or double vault systems and as solar or non-solar systems.
The double vault system comprises of two chambers or vaults, which contain the faecal material in turn. As soon as one chamber is filled with faecal material it will be closed and the other chamber will be used. If the second chamber is also filled, it will be closed. The dried faecal material of the first chamber will be emptied. This chamber will now be in use and the cycle repeated. Single vault systems use containers to store the faecal material. As soon as one container is filled it is either pushed to the back of the toilet for drying or emptied by a service provider. A new container is placed under the toilet seat.
After field visits in Uganda 2005, related to a broader research project which focuses on an assessment of hygienic safety of the solid product of UDDTs [
evaluates and compares the temperatures inside the vaults of solar and non-solar UDDT systems. The main objective of the study is to inform recommendations on the choice of the most appropriate UDDT system. The scientific data presented also strengthen the validity of respective practical experiences with UDDT systems.
This study elaborates if solar panels do increase the temperature inside a vault. The data was collected in 2005. It was suggested the data is out-dated and the current practices already adjusted to existing knowledge. However, discussions with practitioners at different platforms and a literature review (see Section 2.1) showed that there is a need for scientifically based data to move away from the construction of solar UDDTs which are still quite common particularly in East Africa.
There are a vast number of UDDT construction manuals and guidelines available [
The literature review revealed a shift from advocating solar UDDTs to advocating non-solar UDDTs. One example being Tilley [
The evaluation of temperatures inside the vaults of different UDDT systems was based on findings of field visits of 136 ecosan sites in Uganda in 2005. These field visits aimed to provide an overview of the existing situation in Uganda. Based on the collected data the overall research project including user friendliness, reuse of the produced materials, a hygienic safety study and the temperature study was designed. The temperature study discussed in this paper solely assesses the temperature conditions in solar and non-solar UDDTs. It was considered important to assess real life conditions of toilets under use. Therefore preference was given to a field and not to a laboratory/pilot study. Sites for the temperature study were chosen based on the findings of the initial field visits. The data was collected in different climatic regions in Uganda. However, the results are not specific to these regions in Uganda but can be generalised.
The site selection aimed to cover different climate conditions and different technologies to assure the coverage of a broad range of different conditions. The climate of Uganda cannot be categorized into a single climatic zone. Uganda has three sub-climatic zones differentiated mainly by altitude and rainfall. These three climatic regions are namely the Lake Region, the Northern Savannah, and the Southern Highlands. The chosen study sites covered the three climatic zones, tropical rainforest climate, savannah climate, and warm and temperate highlands climate. The lowest annual average temperature at the chosen sites is 10˚C in Kabale and the highest annual average temperature is 26.3˚C in Kitgum (see
Loggers were placed in 36 UDDTs. These UDDTs were any combination of solar and non-solar systems and single and double vault systems. Plastic containers or woven baskets were used in the single vault UDDTs.
Site | Kabale | Bushara Island/Lake Bunyonyi | Rwenshama | Kasese | Kampala | Nagalama | Kitgum | ||
---|---|---|---|---|---|---|---|---|---|
Region | South-Western | South-Western | South-Western | Western | Central | Central | Northern | ||
District | Kabale | Kabale | Rukungiri | Kasese | Kampala | Mukono | Kitgum | ||
Köppen-Geiger Climate* (3) | Oceanic Cfb | Tropical Savannah Aw | Tropical Savannah As | Tropical Savannah As | Tropical Rainforest Af | Tropical Rainforest Af | Tropical Savannah Aw | ||
Altitude | 2000 m (2) | 1960 m (4) | 918 m (4) | 1000 m (2) | 1190 m (2) | 1180 m (2) | 760 m (2) | ||
Temperature- Annual average | 17.5˚C, can drop to 10˚C at night (1) | 21.1˚C (3) | 23.3˚C (3) | 19.0˚C (3) | 21.7˚C (3) | 21.6˚C (3) | 24.3˚C (3) | ||
Average low - Average high temperature | 10˚C - 23˚C (5) | 20.2˚C - 21.8˚C (3) | 22.9˚C - 23.8˚C (3) | 18.9˚C - 19.5˚C (3) | 20.6˚C - 22.7˚C (3) | 20.6˚C - 22.4˚C (3) | 22.8˚C - 26.3˚C (3) | ||
Rainfall-Annual average | 1018 mm (3) | 1155 mm (3) | 942 mm (3) | 917 mm (3) | 1291 mm (3) | 1342 mm (3) | 1223 mm (3) | ||
UDDT Technology (dv = double vault, sv = single vault) | Solar dv | Non-solar dv | Non-solar dv | Solar dv | Non-solar dv | Solar dv | Non-solar sv | Solar sv | Solar dv |
Number of UDDTs | 6 | 1 | 3 | 7 | 1 | 1 | 5 | 8 | 4 |
Total of loggers placed in toilets | 14 | 3 | 14 | 3 | 10 | 16 | 8 | ||
Loggers in Environment | 4 | 1 | 1 | 1 | 4 | 2 | 2 |
*Köppen-Geiger Climate Classification: Aw: Tropical wet and dry, savannah climate. As: Tropical wet and dry during period of high sun and long days, savannah climate. Af: Tropical rainforest climate. Cfb: Warm and temperate, oceanic climate. (1) Kampala Fountain Publishers (2005): Uganda Districts Information Handbook, Expanded Edition 2005-2006, Kampala. (2) http://en.wikipedia.org, (Accessed: 03.11.2014). (3) http://en.climate-data.org, (Accessed: 03.11.2014). (4) http://elevationmap.net, (Accessed: 03.11.2014). (5) http://www.weatherbase.com, (Accessed: 03.11.2014).
To record the data temperature loggers of Maxim Dallas Ltd, MAXIM iButtons, were used. The specific loggers were: High Capacity Temperature Logger DS1922L-F5 and Humidity and Temperature Logger DS1923-F5. These temperature loggers were programmed to take three measurements per day-at 6 am, 2 pm and 10 pm. Two temperature loggers were place inside each selected UDDT. Depending on the UDDT system the loggers were placed either inside the closed vault or inside the container, which was filled, and therefore not in use. One temperature logger was placed on top of the solid material and one in the middle of the pile. An additional temperature logger was placed outside the immediate vicinity of the toilet to record the temperature of the surrounding environment.
In order to assure the longest measurement process possible only recently closed vaults or containers were selected. Shortly before the scheduled emptying, after assuring the maximum storage time of the material possible in the closed vaults/containers, the temperature loggers were collected, read out and the data transferred to an Excel sheet. For logistical reasons some temperature loggers had to be removed after a shorter period. The period of data collection varied between 118 and 364 days.
To assess the variance of point measurements inside the same heap, two toilets received two temperature loggers inside the heap. Analysing the data showed that the difference in temperature at different locations inside the heap is negligible. It therefore was considered justified to only place one temperature logger in each heap. Since financial constraints only allowed the purchase of a limited number of temperature loggers, placing only one logger inside the heap of each study UDDT permitted a larger number of project sites.
In this section the results of the field visits, focusing on the distribution of different technologies, will be discussed briefly. The discussion of the temperature study will be comprehensive. Each site is evaluated separately first to then provide a comparison.
In 2005 133 ecosan sites in Uganda, that is, sites with resource oriented sanitation systems, were visited and evaluated. Several parameters like technology, cleanliness, smell, number of users, urine collection system, designs for washers and wipers, public, private, subsidies, usage of containers, and hand washing facilities were reviewed. The findings and methodology of the field visits, including the inspection protocol, are discussed in detail in a separate paper. This section will focus solely on the findings relevant to the choice of technology.
With the exception of three (2%) sites, all visited toilets were Urine Diversion Dehydration Toilets. Double and single vault systems were installed. 86% (114) of the visited toilets were double vault systems and 12% (16) single vault systems. The three sites with systems other than UDDT were designed for reuse of urine and/or faeces without following any guidelines. Even though the systems are reuse orientated they can’t be labelled “ecosan” since there is no safe sanitization of the faecal material guaranteed.
Only 11% of the double vault systems were constructed without solar heating. 89% (102) of the 114 double vault systems and 50% (8) of the single vault systems were constructed with iron sheets, mostly black, to absorb the heat of the sun and increase the temperature inside the vault. These systems are commonly referred to as solar double/single vault systems. Therefore out of 133 visited UDDTs 110 (83%) were solar heated. The solar heated UDDT was definitely the preferred design.
The visited solar UDDTs were designed in various ways using different materials. Four major problem areas were identified:
1) Because of the tilted chambers, building so called solar heated UDDTs complicates the construction and increases the cost considerably.
2) Inclined vault doors are more exposed to direct rain and therefore corrode much faster depending on the used quality of the iron sheets (see
3) In contrast to vertical vault doors, inclined vault doors have to be watertight due to their exposure to direct rainfall. This cannot always be guaranteed (see
4) The solar UDDTs are not necessarily oriented according to the sun’s path but more likely for the comfort of the user (see
The temperature loggers were collected as soon as the respective vault/basket/container was about to be emptied. During collection of the temperature loggers it became apparent that of the 83 temperature loggers placed in 36 UDDTs and in the environment 21 temperature loggers were missing at the time of sampling. Therefore not all UDDTs studied could be evaluated. If only one of the loggers placed inside the vault was missing the respective data is still discussed. If the logger placed in the environment was missing it was not possible to discuss the respective UDDTs, due to the lack of reference data.
Site | Kabale | Kitgum | Kampala | Nagalama | Rwenshama | ||
---|---|---|---|---|---|---|---|
Total loggers lost, or no data | 4 | 3 | 5 | 2 | 5 | ||
Environment loggers lost | 1 | 1 | 2 | ||||
Technology | Solar double vault UDDT | Non solar single vault UDDT | Solar double vault UDDT | Solar double vault UDDT | Non solar single vault UDDT | Solar single vault UDDT | Solar double vault UDDT |
Final number of evaluated UDDTs | 6 | 1 | 4 | 1 | 3 | 8 | 5 |
Period of data collection in days | 170 - 280 | 118 - 364 | 220 - 310 | 207 - 246 | 150 - 364 |
To illustrate the temperature tendencies over the study period graphically it was decided to present the mean values of the measurements in 10-day intervals. In addition to the graphs, a comparison of minimum and maximum measurements inside the vault with the minimum and maximum measurements in the environment is presented. Furthermore, the mean temperature values inside and outside the heap and in the environment over the whole study period are compared. The following sections evaluate each site separate.
Kabale is located in South Western Uganda at 2000 m above sea level. The climatic region is oceanic with warm and temperate climate. The annual average temperature is between 10˚C and 23˚C (see
Of the 18 data loggers placed in seven toilets and the surroundings four data loggers were missing. Since one missing data logger was placed in the environment, it was not possible to fully evaluate two toilets, KAB 2&3. However, these sites are still included in the discussion since KAB 2 is a single vault solar UDDT immediately neighbouring KAB 3 which is a non-solar UDDT system (see
The study period of KAB 1 is 21.05.2005 to 22.12.2005, 216 days, whereas KAB 2&3 was emptied earlier at 06.11.2005 after 170 days. It can be seen that the trend of the temperature is similar at both sites. Hereby considering KAB 2&3 as one site. Around day 60 there is a temperature low at both sites and around day 9 the temperature reached a maximum again at both sites.
Even though KAB 2 is a solar and KAB 3 is a non-solar UDDTs the temperatures inside the vaults are the same. The toilets are located in the shade. Therefore the construction of a solar panel does not have any effect on the temperature inside the heap, as shown by the measurements. At KAB 2&3 three loggers were missing-two placed outside the heap and one placed in the environment. Therefore a comparison between the temperature outside and inside the heap and a comparison with the temperature in the environment is not possible.
The measurements at KAB 4 were taken from 16.01.2006 until 25.09.2006 for 253 days, at KAB 6 from 16.01.2006 until 14.07.2006 for 180 days and measurements at KAB 5 and 7 were taken from 16.01.2006 until 22.10.2006 for 280 days. The generally lower temperatures of KAB 4, 5, 6, and 7 compared to KAB 1, 2 & 3 might be due to the different monitoring period. Since KAB 4, 5, and 6 are neighbouring sites, one environment logger was used for all three sites. The logger placed outside the heap of KAB 4 disappeared.
The graphs show that at KAB 1 the temperatures inside and outside the heap are above the environment temperature. With the inside and outside temperature being very similar. The temperature inside the heap at KAB 4 is similar or slightly above the environment temperature. At KAB 5 the temperatures inside the vault are similar or slightly below the environment temperature, whereas at KAB 6 the temperature inside the heap is above the environment and the temperature outside the heap is below the environment temperature. At KAB 7 the graph of the temperature inside the heap is mainly above the environment temperature and the graph of the temperature outside the heap similar or below the environment temperature. The visuals of the graphs are reflected in the following tables.
Site | Temperature inside heap | Temperature outside heap | ||
---|---|---|---|---|
Min | Max | Min | Max | |
KAB 1 | 20.67 | 26.17 | 20.67 | 25.17 |
Environment KAB1 | Min | Max | ||
12.64 | 34.65 | |||
KAB 2 | 15.16 | 22.17 | - | - |
KAB 3 | 16.20 | 21.21 | - | - |
No environment measurement for KAB 2&3 available | ||||
KAB 4 | 17.65 | 21.15 | - | - |
KAB 5 | 17.15 | 22.66 | 15.16 | 25.67 |
KAB 6 | 18.65 | 23.15 | 13.65 | 25.67 |
Environment KAB 5 | Min | Max | ||
-Period of 253d (KAB 4) | 9.58 | 31.10 | ||
-Period of 280d (KAB 5) | 9.58 | 31.10 | ||
-Period of 180d (KAB 6) | 10.08 | 31.01 | ||
KAB 7 | 17.15 | 22.66 | 13.65 | 23.67 |
Environment KAB 7 | Min | Max | ||
10.15 | 28.18 |
At all sites the minimum temperatures inside and outside the heap are above the minimum environment temperature, with the difference ranging between 3.5˚C and 8.57˚C. However, the maximum temperatures inside and outside the heap are always below the maximum temperatures in the environment. With the temperature difference ranging between 4.51˚C and 9.95˚C.
Site | Inside | Average | Outside | ||
---|---|---|---|---|---|
Average | Environment | Average | |||
KAB 1 | ↑ | 23.21 | 21.22 | 22.82 | ↑ |
KAB 2 | - | 19.48 | - | - | - |
KAB 3 | - | 19.45 | - | - | - |
KAB 4 | =/↑ | 19.75 | 19.65 | - | - |
KAB 5 | ↓ | 18.95 | 19.64 | 19.21 | ↓ |
KAB 6 | ↑ | 20.34 | 19.70 | 18.75 | ↓ |
KAB 7 | ↑ | 20.23 | 19.39 | 18.80 | =/↓ |
↑: Temperature higher than environment. ↓: Temperature lower than environment.
KAB 1, 5, 6 & 7 had temperature loggers inside and outside the heap. In KAB 1, 6 & 7 the average temperature inside the heap is higher than the average temperature outside the heap and the average environment temperature. For KAB 5 the outside and the environment temperatures are higher than the inside temperature for the last 125 days of the 280 days study period. For the rest of the study period the inside and outside temperature are either the same or the inside temperature is slightly higher. It can be seen that the mean temperatures inside the heap are mostly higher than the environmental temperatures, except for KAB 5. However, the temperature difference between the temperature inside the heap and environment temperature only ranges between 0.10˚C and 1.99˚C. Whereas the temperature outside of the heap is mostly lower or the same than the average environment temperature, the difference ranging between 0.43˚C and 0.95˚C. Only KAB 1 has a slightly higher average temperature outside the heap of 1.6˚C compared to the temperature in the environment. The average temperatures inside the heap being higher than the average temperatures outside the heap and in the environment could be explained by higher daily temperature differences in the environment and outside the heap compared to the better “insulated” inside of the heap.
Kitgum is located in Northern Uganda at 760 m above sea level. The climatic region is tropical wet and dry savannah climate. The annual average temperature is between 22.8˚C to 26.3˚C (see
Of the ten temperature loggers placed, three went missing. These were the loggers placed outside of the heap at three sites. Only at KIT4 the loggers placed inside and outside the heap were available at the time of emptying. However, unfortunately KIT 4 was already emptied after a period of 118 days. For the Kitgum sites it is therefore only possible to compare the temperature outside the heap with the environment. Two loggers were placed in the environment. The data readings are very similar. Therefore the environment logger at KIT1 will be used for the evaluation of KIT 1-4.
The study period of KIT1, 2, and 3 is 05.06.2005 to 03.06.2006, 364 days. The study period for KIT 4 is only 118 days. The temperature trends of all four sites are the same. With only KIT 2 having higher temperatures than the other sites in the first 50 days. For all sites the graphs of the temperature outside the heap is above the graph for the environment temperature. The temperature inside and outside the heap at KIT 4 is very similar.
Site | Temperature inside heap in ˚C | Temperature outside heap in ˚C | ||
---|---|---|---|---|
Min | Max | Min | Max | |
KIT 1 | - | - | 20.15 | 40.13 |
KIT 2 | - | - | 21.18 | 38.65 |
KIT 3 | - | - | 21.11 | 35.60 |
KIT 4 | 24.65 | 32.64 | 21.10 | 33.10 |
Environment KIT 1 | Min | Max | ||
Period of 364 days (KIT 1-3) | 17.66 | 36.16 | ||
Period of 118 days (KIT 4) | 20.17 | 31.67 |
It can be seen from
Site | Average Temperature in ˚C | ||||
---|---|---|---|---|---|
Inside heap | Environment | Outside heap | |||
KIT 1 | - | - | 26.41 | 27.25 | ↑ |
KIT 2 | - | - | 26.41 | 28.28 | ↑ |
KIT 3 | - | - | 26.41 | 27.71 | ↑ |
KIT 4 | ↑ | 25.91 | 25.35 | 26.06 | ↑ |
↑: Temperature higher than environment. ↓: Temperature lower than environment.
Kampala, the capital of Uganda, is located in the South Central part of Uganda close to the shores of Lake Victoria in the climatic region of tropical rainforest. The annual average temperature ranges between 20.6˚C and 22.7˚C and the annual average rainfall amounts to 1291 mm (see
In total 14 data loggers were placed in 6 toilets and in the environment. Five of which went missing. Therefore two sites could not be evaluated at all. At KAMP 1 and KAMP 3 the temperature loggers outside the heap got lost, therefore it was not possible to compare the temperature inside the heap with the temperature outside the heap. The temperature logger placed in the environment at KAMP 4 was lost and got replaced after 165 days, therefore it is not possible to compare the temperature inside the vault with the environment for the first 164 days. The results of the readings of the temperature loggers placed in Kampala are shown in
KAMP 1 was evaluated for 247 days, from 01.04.06 to 03.12.06, and KAMP 4 for 310 days from 28.01.06 to 03.12.06. The measurements at KAMP 2&3 were taken over a period of 220 days, from 21.10.05 to 28.05.06.
The temperature inside the heap of KAMP 1 is lower than the temperature of the environment. For KAMP 2 the temperature in the vault, inside and outside the heap is under or the same as in the environment except for the first 50 days where the temperature inside the heap exceeds the environment temperature and the temperature outside the heap. At KAMP 3 the graph of the temperature inside the vault is above the environment temperature. For KAMP 4 the temperatures inside the vault and in the environment can only be compared after day 165, when the temperature logger in the environment was replaced. The graph of the temperature inside and outside the heap is under the environment temperature until day 240. Then the temperature inside the heap rises slightly above the environment temperature. Until day 225 the inside and outside temperatures are similar. In order to judge the temperature differences
Site | Temperature inside heap in ˚C | Temperature outside heap in ˚C | ||
---|---|---|---|---|
Min | Max | Min | Max | |
KAMP 1 | 19.66 | 26.66 | - | - |
Environment KAMP 1 | Min | Max | ||
18.16 | 30.16 | |||
KAMP 2 | 22.17 | 31.67 | 21.67 | 27.17 |
KAMP 3 | 23.69 | 28.19 | - | - |
Environment KAMP 2&3 | Min | Max | ||
18.17 | 32.67 | |||
KAMP 4* | 20.65 | 26.15 | 20.10 | 24.60 |
Environment KAMP 4 | Min | Max | ||
17.17 | 32.67 |
*Only data from 11.07.06 onwards considered.
Site | Average Temperature in ˚C | ||||
---|---|---|---|---|---|
Inside heap | Environment | Outside heap | |||
KAMP 1 | ↓ | 22.88 | 24.23 | - | - |
KAMP 2 | = /↑ | 25.21 | 24.90 | 24.51 | = /↓ |
KAMP 3 | ↑ | 25.96 | 24.90 | - | - |
KAMP 4* | = /↓ | 23.01 | 23.16 | 22.49 | = /↓ |
↑: Temperature higher than environment. ↓: Temperature lower than environment. *Only data from 11.07.06 onwards considered.
It can be seen that the minimum temperatures inside the vault (inside and outside the heap) are higher than the minimum environment temperatures. The temperature difference ranges between 1˚C and 5.52˚C. However, the maximum temperatures inside the vault never exceed the maximum temperatures of the environment, with maximum temperatures being between 1˚C to 8.07˚C lower inside the vaults than in the environment. Comparing the mean temperatures (see
Nagalama is a town in Uganda’s central region. It is located approximately 38 km by road northeast of Kampala. The study site is situated in the compound of St. Francis Hospital, Nagalama. Like Kampala the climatic region is also tropical rainforest. The annual average temperature ranges between 20.6˚C and 22.4˚C and the annual average rainfall amounts to 1342 mm (see
Sixteen temperature loggers were placed in the vaults of eight UDDTs and two temperature loggers in the environment. Unfortunately both temperature loggers placed in the environment got lost. Therefore the Nagalama sites cannot be fully evaluated. The reason for still including the site in this study lies in an observed phenomenon.
NAG 1 to NAG 4 were evaluated for 207 days, from 08.10.2005 to 02.05.2006, and NAG 5 to NAG 8 for 246 days from 02.04.2006 to 03.12.2006. The two temperature loggers placed in the environment were missing at the time of evaluation. Therefore the temperature inside the vaults of the UDDTs could not be compared with the temperature in the environment and no conclusion could be drawn regarding the heating capacity of the solar panels.
NAG 4 and NAG 8 is the same UDDT but evaluated over different periods (see above). In the first evaluation period three UDDTs were placed at Block 2 and NAG 4/8 was the only study UDDT placed at Block 1, whereas for the second evaluation period three UDDTs, including NAG 4/8, were placed at Block 1, and only one UDDT was placed at Block 2. NAG 4/8 exceeds the temperature of the other study UDDTs significantly only during the first study period; 08.10.2005 to 02.05.2006, when it is the only observed UDDT at Block 1. During the second study period, from 02.04.06 to 03.12.06, the measurements of NAG 4/8 are similar to the measurements of the other two evaluated UDDTs of Block 1, NAG 5 and NAG 6. Only NAG 7 placed at Block 2 exceeds the temperatures of the other study toilets considerably (see
Site | Temperature inside heap in ˚C | Temperature outside heap in ˚C | ||||
---|---|---|---|---|---|---|
Min | Max | Average | Min | Max | Average | |
Study period 1:08.10.2005 to 02.05.2006 | ||||||
NAG 1 | 21.66 | 28.16 | 24.46 | 22.17 | 27.67 | 24.29 |
NAG 2 | 22.66 | 29.16 | 24.67 | 22.64 | 29.14 | 24.81 |
NAG 3 | 22.72 | 27.22 | 24.68 | 21.66 | 26.66 | 24.57 |
NAG 4* | 23.15 | 32.65 | 26.97 | 23.67 | 32.16 | 27.11 |
Study period 2:02.04.2006 to 03.12.2006 | ||||||
NAG 5 | 22.17 | 28.66 | 24.59 | 21.17 | 29.17 | 24.20 |
NAG 6 | 22.15 | 29.15 | 24.24 | 22.14 | 29.14 | 24.70 |
NAG 7 | 22.18 | 30.18 | 25.67 | 23.15 | 29.15 | 26.02 |
NAG 8* | 20.14 | 30.14 | 23.91 | 21.13 | 27.63 | 24.38 |
*NAG 4 and NAG 8 being the same UDDT but observed over different time periods. The highlighted sites, NAG 4 and NAG 7, being located on the opposite block than the rest of the study UDDTs.
It can be seen in
Rwenshama is located in the Western Region of Uganda on the shores of Lake Edward. The distance from Rwenshama to Kampala is approximately 323 km (as the crow flies). The climatic region of Rwenshama is tropical wet and dry savannah climate. The annual average temperature ranges between 22.9˚C and 23.8˚C and the annual average rainfall amounts to 942 mm (see
In general UDDTs in Rwenshama had several problems including misuse, corrosion of iron sheets, weak mortar, insects, flooding and therefore water intrusion. Fourteen data loggers were placed inside the vaults of seven UDDTs and one data logger was placed in the environment. Unfortunately five data loggers were lost. Therefore only five UDDTs could be evaluated.
RWN 4 and RWN 5 were only studied for a period of 150 days, from 12.04.2006 to 08.11.2006, whereas the other UDDTs were studied for 364 days, from 10.11.2005 to 08.11.2006. In RWN 5 the temperature logger placed inside the heap got lost, therefore only the temperature outside the heap is illustrated in
The graphs of the temperatures inside and outside the heap of all study UDDTs are above the environment temperature. At RWN 1 and RWN 3 the temperature inside the heap is above or similar to the temperature inside the heap, whereas at RWN 2 the graph of the temperature outside the heap is slightly below the inside temperature for approximately the first half of the measurement period. For the second half, the outside temperature is slightly above the inside temperature. At RWN 4 the temperature inside and outside the heap is very similar with the outside temperature slightly exceeding the inside temperature from time to time. In order to judge the temperature differences
Site | Temperature inside heap in ˚C | Temperature outside heap in ˚C | ||
---|---|---|---|---|
Min | Max | Min | Max | |
RWN 1 | 24.15 | 34.14 | 19.11 | 33.16 |
RWN 2 | 22.67 | 28.17 | 19.16 | 31.16 |
RWN 3 | 21.61 | 30.65 | 21.15 | 31.16 |
Environment | Min | Max | ||
10.11.05-08.11.06 | 14.16 | 36.66 | ||
RWN 4 | 22.61 | 27.61 | 20.15 | 29.65 |
RWN 5 | - | - | 19.16 | 35.65 |
Environment | Min | Max | ||
12.04.06-08.11.06 | 14.16 | 36.66 |
Site | Average Temperature in ˚C | ||||
---|---|---|---|---|---|
Inside heap | Environment | Outside heap | |||
RWN 1 | ↑ | 26.98 | 23.00 | 25.98 | ↑ |
RWN 2 | ↑ | 25.65 | 23.00 | 25.52 | ↑ |
RWN 3 | ↑ | 26.46 | 23.00 | 26.00 | ↑ |
RWN 4 | ↑ | 25.24 | 22.97* | 25.48 | ↑ |
RWN 5 | - | - | 22.97* | 26.93 | ↑ |
↑: Temperature higher than environment. ↓: Temperature lower than environment. *Only data from 12.04.2006 onward considered.
In all study UDDTs in Rwenshama the average temperatures inside and outside the heap are above the average environment temperature (see
After evaluating every site separately, this chapter compares the findings of the different sites to inform general conclusions and recommendations. Of 28 evaluated UDDTs four were non-solar UDDTs (see
Site/climatic region | ΔTemp 1 = inside Temp-environment Temp | Δ Temp 2 = outside Temp-environment Temp | ||||||
---|---|---|---|---|---|---|---|---|
Inside Temp higher | Environment Temp higher | Outside Temp higher | Environment Temp higher | |||||
No of UDDTs | Variation of ΔTemp 1 in ˚C | No of UDDTs | Variation of ΔTemp 1 in ˚C | No of UDDTs | Variation of ΔTemp 2 in ˚C | No of UDDTs | Variation of ΔTemp 2 in ˚C | |
Highlands | ||||||||
Kabale | 4 | 0.10 - 1.99 | 1 | 0.69 | 1 | 1.6 | 3 | 0.43 - 0.95 |
Rainforest | ||||||||
Kampala | 2 | 0.31 - 1.06 | 2 | 0.15 - 1.35 | - | - | 2 | 0.39 - 0.67 |
Savannah | ||||||||
Kitgum | 1 | 0.56 | - | - | 4 | 0.71 - 1.87 | - | - |
Rwenshama | 4 | 2.27 - 3.98 | - | - | 5 | 2.51 - 3.96 | - | - |
Even though the 8 non-solar UDDTs evaluated in Nagalama could not be compared to the environment since the respective temperature logger got lost and the 4 evaluated non-solar UDDT systems in Kampala and Kabale did not show a clear trend with the average temperatures inside the vault being above, below and similar to the average environment temperatures general tendencies can be observed.
The evaluation of temperatures inside the vaults of solar and non-solar UDDT systems in Uganda shows that at most sites the average temperatures inside the vaults are above the average temperatures in the environment (see
When comparing the temperature values of Rwenshama with the measurements in Kitgum, which is also located in a tropical savannah climate it becomes apparent that in Kitgum the temperatures inside the vault only rise up to 1.87˚C above the environment temperature. This can mainly be explained by the different climate classification according to Köppen-Geiger (see
Of the original ten non-solar study UDDTs only four could be finally evaluated. Two of these non-solar study UDDTs, KAB 3 and KAMP 3, are immediately beside a solar UDDT (see
The study concentrated on operational UDDTs. The placement of the loggers and the scheduling of the sampling were therefore dependent on the filling pattern of the specific UDDTs. Only UDDTs with vaults filled at a certain time could be used for the study. Therefore the choice of specific design, location and orientation of the study UDDTs was limited and not balanced. Constructing study sites could have addressed these issues. However, the compromises were considered necessary to draw a more realistic picture.
The main factors limiting this study were lost, misplaced or not recovered data loggers and therefore missing data (see Section 4.2). At some sites the temperature logger recording the temperature of the environment was missing; therefore the temperature inside the vaults could not be compared and a supposed temperature rise not evaluated. Some data loggers also compromised data. These temperature measurements were not usable. Some data loggers were placed in UDDTs located in conflict zones with limited infrastructure. At the planned time of recovery the means to recover these temperature loggers were not available. The existing technologies today, allowing for real time remote data logging, would prevent this problem. Irregularities, loss and failure can be realised without delay and respective measures taken. Far less logistical planning is necessary.
Overall limited resources did not allow for a bigger sample size and only a restricted number of non solar UDDTs were available for the study.
In spite of the limitation described above the presented results allow for general conclusions and recommendations considering that an effective sanitation system should be hygienically safe and as user friendly and cost effective as possible. It was observed that even though solar UDDTs are designed to use the irradiation for heating they are not always located in a place where absorption of solar irradiation would be possible, such as shady places. Furthermore, the study shows that the temperature inside the vaults of solar UDDTs is not necessarily higher than inside the vaults of non-solar UDDTs. With the exception of Rwenshama, even if there is a temperature increase achieved, it is too minimal to justify the higher investment cost and the problems associated with the construction of solar UDDTs (see Section 4.1). The achieved temperatures are not high enough or held long enough to significantly increase the rate of dehydration or to even facilitate any hygienisation effect. However, the significant temperature rise inside the vaults of UDDTs located at Rwenshama shows the importance of the climatic region.
The recommendation based on the results of this study is therefore not to promote the construction of solar UDDTs as a standard solution any longer, but to rather promote non-solar UDDT designs as standard solutions. The decision for solar UDDTs has to be site specific. Before deciding for a solar UDDT the climatic conditions have to be thoroughly assessed. The extra cost of the construction of a solar UDDT has to be justified. The final solar design needs to be optimised with high quality to avoid unnecessary cost and associated problems.
Constructing non-solar UDDTs will give more freedom regarding the location and orientation of the UDDTs. Particularly for urban contexts single vault non-solar UDDT systems combined with a service provider for operation and maintenance are considered to be most appropriate. Also other ecosan technologies, such as Terra Preta Sanitation [
The present study should be also seen in relation to the Ascaris die-off study currently under evaluation [
This study was part of a PhD research project hosted and funded by Hamburg University of Technology TUHH and Rosa-Luxemburg-Foundation. The author would like to acknowledge the Austrian Development Agency, the Directorate of Water Development Kampala, and South Western Towns Water and Sanitation Project (SWTWS) for their generous support.
Constanze Windberg,Ralf Otterpohl, (2016) Solar versus Non-Solar Urine Diversion Dehydration Toilets—Evaluation of Temperatures inside the Vaults of Different UDDT Systems. Journal of Environmental Protection,07,1221-1243. doi: 10.4236/jep.2016.79109