Journal of Power and Energy Engineering, 2014, 2, 64-73
Published Online September 2014 in SciRes. http://www.scirp.org/journal/jpee
http://dx.doi.org/10.4236/jpee.2014.29010
How to cite this paper: Rhee, B.W. and Kim, H.T. (2014) A Review of the Scaling Study of the CANDU-6 Moderator Circula-
tion Test Facility. Journal of Power and Energy Engineering, 2, 64-73. http://dx.doi.org/10.4236/jpee .2014. 29010
A Review of the Scaling Study of the
CANDU-6 Moderator Circulation Test
Facility
Bo Wook Rhee, Hyoung Tae Kim
Severe Accident and PHWR Safety Research Division, Korea Atomic Energy Research Institute (KAERI), Daejeon,
Republic of Korea
Email: bwrhee@kaeri.re.kr
Received July 2014
Abstract
Following the previous relevant works [1]-[3], a scaling analysis is performed to derive a set of
scaling criteria which were thought to be suitable for reproducing the major thermal-hydraulic
phenomena in a scaled-down CANDU moderator tank similar to that in a prototype power plant
during a full power steady state condition. The objective of building a scaled-down moderator
tank is to generate the experimental data necessary to validate the computer codes which are
used to analyze the accident analysis of CANDU-6 plants. The major variables of interests in this
paper are moderator flow velocity and temperature of the moderator which is D2O inside the
moderator tank during a steady state and transient conditions. The reason is that the local sub-
cooling of the moderator is found to be a critical parameter determining whether the stable film
boiling can sustain on the outer surface of the calandria tube if the contact of overheated pressure
tube and cold calandria tube should occur due to pressure tube ballooning during LBLOCA with
ECC injection failure [4]. The key phenomena involved include the inlet jet development and im-
pingement, buoyancy force driven by the moderator temperature gradient caused by non-uniform
direct heating of the moderator, and the pressure drop due to viscous friction of the flow across
the calandria tube array. In this paper, the previous researches are reviewed, some concerns or
potential problems associated with them implied by comparing CFD analyses results between the
CANDU-6 moderator tank and 1/4 scaled-down test facility are described, and as a way to examine
the assumption of the scaling analysis is true an order-of-magnitude analyses are performed.
Based on the results of these analyses the assumption of neglecting
( )
2
V
∗∗
and
( )
2
T
∗∗
terms
cannot be justified for the power of 0.5 MW and 1.566 MW for the 1/4 scaled-down facility. Further
investigation is thought to be necessary to confirm this result, i.e. if the scaling of the previous
work1 is justifiable by some other independent analyses.
Keywords
CANDU-6, Thermal-Hydraulic Phenomena, Moderator Tank, Experimental Test Facility, Scaling
Analysis
B. W. Rhee, H. T. Kim
65
1. Introduction
In order for a computer code to be qualified to predict the local subcooling of the moderator during major DBAs
in CANDU-6 reactor for licensing application, it is necessary to have enough experimental data appropriate to
validate the computer code. As most of the experimental data relevant to moderator circulation and temperature
of a CANDU-6 reactor are restricted for either publication or sharing through IAEA/OECD-NEA due to the
proprietary nature, it was hard for Korean R&D institutes to acquire the experimental data necessary to validate
their computer codes for moderator circulation and subcooling analyses of CANDU-6 plants. Thus it was de-
cided to erect an experimental test facility from which the experimental data necessary to validate the computer
codes for moderator circulation and subcooling analyses for licensing application as a part of the medium and
long range nuclear R&D program. For this purpose a scaling study of the moderator circulation of a CANDU-6
reactor started at KAERI.
According to the literature survey, several scaling studies have been performed to derive a set of scaling crite-
ria which were thought to be suitable for reproducing the major thermal-hydraulic phenomena in a scaled-down
CANDU moderator tank similar to that in a prototype power plant during a full power steady state condition.
The major variables of interests in these papers are moderator flow velocity and temperature of the moderator
which is D2O inside the moderator tank during a steady state and transient conditions. The reason is that the lo-
cal subcooling of the moderator is found to be a critical parameter determining whether the stable film boiling
can sustain on the outer surface of the calandria tube if the contact of overheated pressure tube and cold calan-
dria tube should occur due to pressure tube ballooning during LBLOCA with ECC injection failure. The key
phenomena involved include the inlet jet development and impingement, buoyancy force driven by the modera-
tor temperature gradient caused by non-uniform direct heating of the moderator, and the pressure drop due to
viscous friction of the flow across the calandria tube array.
2. CANDU-6 Moderator Circulation Test Facility Scaling Strategy of KAERI
2.1. Rationale of Scaling Study up to Now
In this study the governing equations were transformed into dimensionless equations based on the representative
characteristic values of the basic design such as the time, tank diameter, inlet jet velocity, and the moderator
temperature rise across the tank. Then 3 dimensionless numbers, Re, Pr, Ar, were identified as those character-
izing the key phenomena of the system. The relevant boundary conditions were then identified in a dimen-
sionless form, and the compatibility of keeping these 3 dimensionless numbers, the volumetric heat source dis-
tribution, and the boundary conditions in dimensionless forms the same for both the prototype and scale-down
tanks were examined, and some of them that are judged to be less important are relaxed so as to find a practi-
cally implementable set of constraints. The size of the scaled-down moderator tank and corresponding inlet jet
velocity are then found for the available power supply size. As an example, an analysis was performed for a
power supply capacity of 1.566 MW and 0.5 MW as compared to 100MW for the prototype.
2.2. Attempts to Prove the Validity of Scaling Study
As a way to confirm the validity of the current work two numerical CFD simulations were carried out with the
boundary conditions at the inlet and outlet ports, and on the walls of the solid structures, such as the moderator
tank and calandria tubes, which were derived from those of the dimensionless scales to check if the moderator
flow and temperature patterns of both the prototype reactor and scaled-down facilities are identical or at least
similar. A steady-state solution is first obtained for the CANDU-6 reactor normal operation. Similar simulation
was done for the scaled-down facility and results presented. Comparison results are discussed, and the cause of
the potential distortion of the scaling owing to practical limitations and possible solutions is finally discussed.
3. Derivation of Dimensionless Governing Equations and Boundary
3.1. Dimensionless Governing Equations and Boundary
V0∇⋅ =
( )
2ref
ref refref
ρ ρ
V1μ
V VPVg
tρ ρρ

+⋅∇= −∇+∇+

B. W. Rhee, H. T. Kim
66
( )
2
ref pref p
T kq
VT T
tρCρC
+⋅∇=∇ +
According to a previous study by Khartabil [1], the dimensionless variables can be defined as below,
( )
( )
*** 2
isatref i
VV,TTTT,PP ρUU= =−∆=
2
ρrefii
Pr μCk, Argβ(TT )DU== −
( )
*
refp i
q x,y,z,t
qρCΤ
h
d
U
=
,
oi
T(TT)∆= −
The following dimensionless governing equations can then be derived
**
V0∇=
()( )
*2
* *******
*
V 1g
V VPVArT
Re g
t
ϑ
ϑ
+∇= −∇+∇−
(1)
()( )
*2
** ****
*
T1
V TTq
RePr
T
ϑ
ϑ
+∇ =∇+
(2)
Boundary Conditions:
- on a fixed solid surface (in case of wall heating):
*
V0
=
,
"* "*
qq
w
=
- at an inlet or outlet: Known
**
V ,T
or
*
P
.
3.2. Conflict between Re and Ar Similarity
If the same working fluid is used for both the prototype and the scaled-down facilities
Pr
can be considered
nearly uniform inside the tank. Also Re and Ar will depend on
T
,
i
U
, and D. Therefore, if any combination
of
T
,
i
U
, and D for which Re, Ar, and the dimensionless volumetric heat source,
*
q,
may be kept the same
for both facilities, the hydrodynamic similarity inside the moderator tank is maintained. However, in practice,
maintaining both Re and Ar the same for the prototype tank and the scaled-down tank turns out to be impossible
as the tank dimension for the scaled-down tank becomes larger than the prototype tank dimension. Maintaining
similarity in Re is not possible because of the need for a reduced tank size. According to Khartabil’s argument
[1], the impact of abandoning the Reynolds number equivalence is that the relative contributions of the momen-
tum and energy diffusion by molecular motion are not the same between the prototype and scaled-down facility,
and by ensuring a turbulent flow prevail throughout the tank, the relative contributions of these diffusion proc-
esses represented by the Laplace operator on V* and T* to the overall balances in Equations (1) and (2) can be
neglected. Thus, if Re is large enough to guarantee a turbulent flow throughout the moderator tank for both fa-
cilities, it can be justified that the overall similarity for both the prototype and scaled-down tanks be reasonably
kept. However how can it be ensured for the flow inside the tank, including the inner tube bank region during
steady as well as transient conditions remains questionable. To confirm if this turbulence assumption is true or
not, one would need to perform CFD analyses for both the prototype and scaled-down facilities for the normal
steady state conditions
3.3. Determination of the Operating Conditions Using the Ar Similarity
If the argument of Khartabil is assumed to be true, one then only needs to be concerned how to keep Ar and q
the same for both the prototype and scaled down tanks.
2
,
,


=




im
m PP
P mm
iP
U
TDβ
TU Dβ
(3)
B. W. Rhee, H. T. Kim
67
However, ΔTm/ΔTP cannot be determined arbitrarily, but needs to be subject to another constraint of the ca-
pacity of the power supply,
( )
mm
qx,y,z,t dVQ=
∫∫∫
,
and the heat source distribution similarity condition or dimensionless volumetric heat source, as claimed by
Khartabil [1],
( )
( )
( )
( )
P Pm m
ref p iref p i
Pm
qx,y,z,tDqx,y,z,t D
ρCU TρCU T
=
∆∆
The integration of these dimensionless volumetric heat sources over the whole dimension less tank volume of
each facility is necessary for the closure of the equations.
If both sides of this equation are integrated over the relevant space domains, we obtain another constraint as
below:
( )( )
Pm
22
ref p iPref p im
Pm
QQ
ρCU TDρCU TD
=
∆∆
(4)
Thus, if Equation (4) is inserted into Equation (3), one can obtain
( )
( )
3
,
,
piP
PP
m im
pm
CU
D
DU
C
ρ
ρ



=




 
Pm
mP
Qβ
Qβ
(5)
From this equation, one can determine the ratio of the inlet average velocity once the heat load ratio and geo-
metry scale are fixed. This inlet average velocity ratio in turn is determined (
m
P
T
T
) from Equation (3). If
m
T
and
m
D
are acceptable from the viewpoints of coolant temperature measurement accuracy and the space avail-
able for the instruments installation and probe accessibility, one can fix this combination of Q, D and
T.
(1) Power Supply of 0.5 MW Case
The power supply of the scaled-down moderator tank is 500 kW, and the diameter is fixed to be 1.9 m and the
length is 1.5 m, which is 1/4 of the prototype tank. If these values are inserted into Equation (4) and
ref p
ρC
assumed the same one obtains
,
,
3.956.
iP
im
U
U


=

As the inlet nozzle velocity of the prototype,
,
,
iP
U
is 2.05 m/s,
,im
U
becomes 0.518 m/s.
(2) Power Supply of 1.566 MW Case
The power supply of the scaled-down moderator tank is 1.566W, and the inlet nozzle velocity can be found to
be
,im
U
becomes 0.7583 m/s.
4. CFD Analysis for Both Power Cases
A steady-state solution is first obtained for normal reactor operation prior to the transient or accident using the
mesh grid configuration shown in Figure 1 using a computer code, MODTURC_CLAS [3] for a full power op-
erating condition as shown in Table 1, where a moderator heat load of 100 MW, a total inlet flow of 940 l/s or
equivalently 1016 kg/s and outlet temperature of 69˚C as design values and the steady-state simulation shows
the maximum temperature in the moderator core region of 84˚C, while the bulk average temperature is 74.3˚C,
as shown in Figure 2.
The steady state operating of the scaled-down test facility as determined 1/4 of the prototype reactor is simu-
lated using the grid structure as shown in Figure 3. For the simplicity only a right half of the total tank is simu-
lated while the whole circular domain of the tank is simulated. Note that the grid structure of the circular planes
at various axial locations is different from that of the prototype reactor. The reason is because the CFD computer
code used for this analysis is an in-house computer code developed at KAERI for past several years, and due to
its restriction on the grid generation, a grid structure as shown in the right side of Figure 3 is used. The steady
B. W. Rhee, H. T. Kim
68
Figure 1. 3-dimensional grid configuration.
(a) x = 3.0 m (b) y = 0.0 m
Figure 2. Moderator velocity and temperature distribution under a full power steady state.
Figure 3. 3-D grid configuration for scaled-down facility.
Table 1. CANDU-6 moderator tank operating condition.
Parameter Values
Moderator tank thermal load 100 MW
Exit temperature 70.6˚C
Inlet mass flow rate 1016 kg/s
Fractional inlet mass flow rate ratio (Left:Right) 49:51
state operating condition is summarized in Table 2 for the 1/4 scaled-down test facility. The analysis result is
shown in Figure 4 and Figure 5.
B. W. Rhee, H. T. Kim
69
Table 2. Scaled-down moderator tank operating condition at
full power steady state.
Parameter
Values
Moderator tank thermal load
500 kW
Exit temperature
47.3˚C
Inlet Mass flow rate
17.287 kg/s
Fractional inlet mass flow rate ratio (Left:Right) 49:51
(a) Temperature at the plane where exit port locates (b) Velocity at the plane where exit port locates
Figure 4. Moderator temperature and velocity distribution at the cross section where inlet and exit
ports are located at full power steady state (1/4 scaled-down facility).
Figure 5. Moderator temperature distribution at full
power steady state (1/4 scaled-down facility).
5. Order of Magnitude Analysis
To examine if the argument that if Re is large enough to guarantee a turbulent flow throughout the moderator
tank for both facilities, it can be justified that the overall similarity for both the prototype and scaled-down tanks
be reasonably kept is valid or not, an order of magnitude analysis is performed for both CANDU-6 full power
steady state and 1/4 scaled-down moderator tanks. The thermal power of the scaled-down tank is both 500 kW
and 1566 kw cases.
5.1. CANDU-6 Full Power Steady State
D7.6m, Pitch0.286m= =
B. W. Rhee, H. T. Kim
70
i
u2.043m / sec,=
3
1085 /mkg
f
ρ
=
μ0.00055kg / ms= ⋅
,
out in
T70.6 CT47.274 C= =
Pr 1
h
D 0.138m=
ref
T3
2
in out
TT
=
()
V0.5m/sec assumed
=
*
Ddδ
dx 26.573
D
Pitch=∇==
*
V 0.245
i
v
u=
=
*2 *
1() 72.796V=∇
i5
5. 70
e56 1
R
fh
UD
ρ
µ
= ×
=
**
0.5 2
ref
out in
TT
TT
TT
=⇒ ≤≤
max
3
2
out in
in
TT
TTT
≤≤


T 23.C33∆=
,
1( 6
20) 7.
in out
TTT=≅+
*
3.03T
*2 *4
13.() 110
Re 04V
=∇×
**
0.208 0.6302Ar TT
⋅ ×≈=
*2 *
0
1( .0)
R04
e38 .V∇ =
Thus
*2 **
1( )Ar
Re VT
∇⋅
.
Now, look into the energy equation,
*
i
* 0.013
fp
D
qq CU T
ρ
=
′′′
=
*2 *3
1()3.84 10
Re T
∇ ≈×
Therefore,
**2 *
1()
Re
qT
i.e., the 2nd term in the RHS of the dimensionless energy equation is negligible.
5.2. 1/4 Scaled-Down Tank with 0.5 MW Case
D1.9m, Pitch0.072m,==
0.519m / sec
i
u=
3
992.6/m3kg
f
ρ
=
0.00055kgμ/m s= ⋅
43,35, PrC1C
out in
TT= =≈
( )
0.13
1
480.0345
h
D= =
B. W. Rhee, H. T. Kim
71
3
2
in out
ref
TTT
=
( )
V0.1m/sec assumed=
*
1.91.9 )
0.07 26.573(
2 0.0715
D
Pitch
= =∇= =
*0.1 0.193
0
V.519
i
v
u
= ==
*2 *
1() 36.1V=∇
4
Re3.233 10= ×
*2 *3
14.() 2 10
Re 09V
=∇×
**
0.208 0.208Ar TT≈=⋅×
*8
T
TT
T∆=
*
1 39
()39 C, 4.875
28
in out
T TTT≅==+=
2
*2 *
4
1(26.573)(4.875)
()
Re 3.2 0.10
33 1065T=∴∇ =×
*
*
fp in
D
qq Cu T
ρ
′′′
=
*
i
0.0112
ρ
p
QD
qCUT



= =
( )
2
**
10.1065
Re T∇≈
( )
*
2
**
0.0112 0.1055
10.1065
Re
q
T
∴==
**2 *
()qT
≈∇
Therefore the 2nd term in the RHS of the dimensionless energy equation cannot be neglected.
5.3. 1/4 Scaled-Down Tank with 1.566 MW Case
D1.9m,Pitch0.072m,0.8055m /sec
i
u===
3
mμ992.63kg/,0.00055kg/m s
f
ρ
== ⋅
49.7,35, PrCC1
out in
TT==≈
( )
V0.1m/sec assumed=
*1.9
0.07 26.5
273
D
Pitch
∇== =
*
V 0.124
i
v
u
= =
*2 *
8() 7.66V=∇
4
5.01R054e1= ×
*2 *3
1( )10
Re 1.75V
=∇×
B. W. Rhee, H. T. Kim
72
**
0.208 0.208Ar TT≈=⋅×
*1 C
4.7
T
TT
T∆=

42.35 C
1(
2,)
in out
T
TT=
≅+
Thus,
*
42.35 2.88
14.7
T==
2
*2 *
4
1(26.573)(2.88)
( )0.0405
Re 5.0154 10
T∴∇ ==
×
*
i
*
fp
D
qq CUT
ρ
′′′
=
*
i
0.01424
ρ
p
QD
qCUT


 =
=
( )
*
2
**
0.01424 0.3166
10.045
Re
q
T
∴==
**2 *
()qT
<∇
Therefore the 2nd term in the RHS of the dimensionless energy equation cannot be neglected.
According to the results of these analyses, for both 0.5 MW and 1.566 MW cases the argument of Kartabil [1]
cannot be justified. This means that the dynamic similarity between the prototype CANDU-6 moderator tank
and those of 1/4 scaled-down tank cannot be guaranteed for the power of 0.5 MW and 1.566 MW.
6. Discussion and Summary
As shown in the Figures on the temperature and velocity distributions of the moderator circulation for the
CANDU-6 prototype tank and the 1/4 scaled-down tank, the velocity and temperature field patterns are quite
different for the respective full power steady state operating condition. If one examines the velocity profile of
the scaled-down case, the inlet jet front does not even reach the top of the tank, not does collide, unlike the pro-
totype case, where two opposing jets collide a little at the right hand side of the top half of the tank as clearly
shown in Figure 2(a). Also the temperature distribution in Figure 4(a) demonstrates the same result clearly.
The authors think if this CFD analysis is correct, the scaling analysis based on the Ar number and the same di-
mensionless heat source distribution has a serious drawback. The authors are now examining if any important
phenomena of the moderator circulation are left out in the scaling analyses, and one thing clearly said is the
definition of the Ar number as the measure of the ratio of buoyancy to the local inertial force based on the tem-
perature difference between the inlet and outlet temperature,
T
, fails to properly account for the buoyancy
force due to direct heating.
One result implying failure to reproduce the flow characteristics of the prototype CANDU-6 reactor is that the
inlet jet front of the scaled-down CFD does not even reach to the top of the moderator tank. This shows that the
current scaling based on Ar using
T
cannot account for this buoyancy driven phenomena as well as the inlet
jet impingement phenomena properly for the MCF with the power of 0.5 MW. As the Re number similarity at
the inlet jet nozzle was neglected in the similarity analysis, let alone the argument if it is a proper parameter for
accounting for the jet development and collision phenomena, applying the scaling law based on Khartabils ap-
proach may lead to a serious error in reproducing the important phenomena in MCF unless the validity of the
key assumptions is carefully examined for the power supply capacity and inlet flow conditions.
As an way to confirm this validity an order of magnitude analyses was carried out and it was found that the as-
sumption of neglecting viscous friction terms in the energy equation cannot be justified for the power levels of
both 0.5 MW and 1.566 MW power supplies.
In conclusion, a porous media CFD analysis of the moderator circulation for the CANDU-6 reactor and the
1/4 scaled-down test model revealed a serious discrepancy in the flow distribution as well as the temperature
B. W. Rhee, H. T. Kim
73
distribution. The possible reasons for this discrepancy were discussed, to figure out the reason for this mismatch
an order of magnitude analyses were performed and neglecting the viscous friction term in the energy equation
cannot be justified. Further research is thought to be necessary to confirm this result, i.e. if the scaling of the
previous work [1] is justifiable by some other independent analyses.
Acknowledgements
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea gov-
ernment (Ministry of Science, ICT, and Future Planning) (No. NRF-2012M2A8A4025964).
References
[1] Khartabil, H .F., et al. (2000) Three-Dimensional Moderator Circulation Experimental Program for Validation of CFD
Code MODTURC_CLAS. 21th CNS Nuclear Simulation Symposium.
[2] Rhee, B.W. and Kim, H.T. (2012) Derivation of the Scaling Criteria for a Small Scale CANDU Moderator Test Facil-
ity. Transactions of the KNS Spring Meeting, Jeju, 17-18 May 2012.
[3] Rhee, B.W., Kim, H.T., Park, S.K., Cha, J.E., Choi, H.-L. (2013) A Scaling Analysis of a CANDU-6 Moderator Tank
Scaled-Down Test Facility . Proceedings of the 21 st International Conference on Nuclear Engineering, ICONE21, 29
July-2 August2013, Chengdu.
[4] Gillespie, G.E., Moye r, R.G . a nd Thompson, P.D. (1982) Moderator Boiling on the External Surface of a Calandria
Tube in a CANDU Reactor during a Loss-of-Coolant Accident. Proceedings of the International Meeting on Thermal
Nuclear Reactor Safety, 29 August-2 September 1982, Chicago, USNRC, Report No. NUREG/CP-00, AECL-7604.