Journal of Cancer Therapy
Vol.07 No.12(2016), Article ID:71847,12 pages
10.4236/jct.2016.712086

The Diagnostic Value of Serum TgAb in the Tg-Negative and TgAb-Positive DTC Patients after Successful Ablation

Qun Fan1, Xinhui Su1, Anren Kuang2*

1Department of Nuclear Medicine, Zhongshan Hospital, Xiamen University, Xiamen, China

2Department of Nuclear Medicine, West China Hospital, Sichuan University, Chengdu, China

Copyright © 2016 by authors and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY 4.0).

http://creativecommons.org/licenses/by/4.0/

Received: September 19, 2016; Accepted: November 6, 2016; Published: November 9, 2016

ABSTRACT

Objective: The aim of this retrospective study was to evaluate diagnostic accuracy of serum thyroglobulin antibody (TgAb) in thyroglobulin (Tg)-negative and TgAb- positive (TgTgAb+) patients with differentiated thyroid carcinoma (DTC). Method: We studied 341 patients with histologically confirmed DTC who had undergone remnant ablation and showed TgTgAb+ assessed by electrochemiluminescence immunoassay (ECLIA). The cases were divided into two groups, including recurrence group 119 cases and no evidence of disease (NED) group 222 cases. Receiver operating characteristic (ROC) curve analysis was carried out. The symmetric measures of the two diagnostic methods (the golden standard and the diagnostic standard as serum TgAb level alone) were analyzed using McNemar test and measure of agreement Kappa. Results: Serum TgAb level (1381.292 ± 1017.221) IU/ml of patients with recurrent group was significantly higher than that (125.559 ± 314.047) IU/ml of NED group (P = 0.000 < 0.001). The area under the ROC curve was 0.962 and its asymptotic 95% confidence interval (CI) was (0.942, 0.982) that was high statistical significance. The cut-off value of TgAb was determined and interpreted at 246.695 IU/ml with sensitivity (92.40%) and specificity (92.30%). McNemar test showed that the diagnostic results of the two methods were not significant difference (P = 0.230 > 0.05). Measure of agreement Kappa was 0.841, P = 0.000 < 0.001 that showed the agreement of the two diagnostic methods was significant. Conclusion: Serum TgAb is a useful tumor marker for recurrence in Tg-negative and TgAb-positive DTC patients who underwent thyroidectomy and remnant ablation. The cut-off value of TgAb is 246.695 IU/ml, that is to say, serum TgAb level upon 246.695 IU/ml may be associated with the persistence or recurrence of DTC.

Keywords:

DTC, TgAb, Cut-Off Value

1. Introduction

Serum thyroglobulin (Tg) level and 131I whole-body scanning (WBS) are the leading recognized sensitive and specific tools for the detection of recurrence or metastases during follow-up of thyroidectomized patients with differentiated thyroid carcinoma (DTC) who underwent remnant ablation. These have been widely accepted management protocols [1] [2] . However, the presence of serum anti-Tg antibody (TgAb) may interfere with Tg measurement made by immunometric assay (IMA) or radioimmunoassay (RIA) methods and cause false results [3] [4] [5] [6] . In the presence of TgAb, IMA methods consistently underestimate serum Tg levels, while RIA methods generally overestimate serum TG levels [5] [6] [7] . Previous studies have showed the incidence of TgAb-positive (TgAb+) in DTC patients ranges from 10% to 30% [8] [9] [10] [11] [12] and about 20% - 30% have been proven recurrence or metastasis among the TgAb+ DTC patients. TgAb currently compromises the use of serum Tg as a tumor marker in this kind of DTC patients. Also, TgAb has been studied extensively in order to evaluate its place in clinical practice [8] - [13] . Serum TgAb levels can be used as a marker for the studied patients that have been shown to be cost-effective in a few studies [8] - [17] , but its possible diagnostic benefit remains controversial. And, it has not been confirmed the diagnostic significance of elevated serum TgAb levels with TG-undetectable and TgAb- detectable (TgTgAb+) DTC patients.

Therefore, the aims of the present study were to evaluate diagnostic accuracy of serum TgAb in TgTgAb+ DTC patients who had previously received thyroidectomy and radioiodine ablation therapy and ascertain the cut-off value of TgAb to differentiate between the pathologic and disease-free patients.

2. Materials and Methods

2.1. Patients

We performed a retrospective review on medical records of1236 patients with histologically confirmed DTC who were admitted to the Nuclear Medicine Department of Zhongshan Hospital Xiamen University from January 2001 to December 2014. All patients underwent total or subtotal thyroidectomy, followed by radioiodine remnant ablation completely and thyroid hormone suppression of thyroid-stimulating hormone (TSH).

According to the collecting and excluding standards, 341 patients entered the study finally. The patients were divided into the recurrence group (n = 119) and no evidence of disease (NED) group (n = 222) on the basis of the golden standard.

2.2. Definitions

A serum TG level of below 1 µg/L with suppressed TSH levels or 2 µg/L with stimulated TSH levels was considered undetectable (Tg). We defined TgAb-detectable (TgAb+) as upon 10 IU/ml. Recurrence was defined as either a regional recurrence and/or distant spread.

The DTC patients with TgTgAb+ and successful ablation of thyroid remnant en- rolled the study. The DTC patients with TG-detectable, TgAb-undetectable (Tg+TgAb) or thyroid remnant in thyroid bed were excluded the study. The gold standard for the study was either the diagnosis of recurrence established by biopsy and/or the diagnosis of the routine clinical examinations (chest x-rays, CT scanning, neck high-resolution echography and radioiodine whole body scan).

Sensitivity (Sen) and specificity (Spe) were defined as true positive and true negative, respectively. Positive likelihood ratio (+LR) was defined as the ratio of the true positive and false positive (Sen/1 ? Spe). Youden Index (YI) = Sen + Spe ? 1. Pre-test probability is defined as the probability that a patient suffers from recurrence or metastases by means of his/her medical history and physical sign. Post-test probability is defined as the probability of recurrent disease in a patient with a certain test result of TgAb. Pre- test odds = pre-test probability/(1 ? pre-test probability). Post-test odds = pre-test odds × (+LR). Post-test probability = post-test odds/(1 + post-test odds).

2.3. Serum Tg and TgAb Assays

Serum Tg level was determined by means of electrochemiluminescence immunoassay (ECLIA) method using a commercially available kit (Roche Diagnostics GmbH), which has a measuring range of 0.100 - 1000 µg/L. The intra- and interassay coefficient of variability (CV) were 1.8% and 3.2%, respectively.

Serum TgAb level was measured by means of ECLIA method (Roche Diagnostics GmbH) with measurable range of 10 - 4000 IU/ml. The intra- and interassay CV were 5.2% and 7.3%, respectively.

2.4. Statistical Analysis

Data were expressed as mean ± SD. Statistical analysis was done using Independent-samples t test and the χ2 test. A P-value of less than 0.05 was considered to indicate a statistically significant difference.

The analysis of diagnostic value was performed by receiver operating characteristic (ROC) curve at the time of evaluation. The nonparametric method could be used to estimate the area under ROC curve. The area under the ROC curve (AUC) with 95% confidence interval (CI) was calculated to express the overall diagnostic accuracy of the test. The AUC, P value, and cutoff point were obtained from the curve. The cut-off value was defined as the threshold value of the maximum Youden Index (YI). Corresponding to Spe, Sen, PV and LR were calculated for the cut-off value in contingency tables.

The symmetric measures of the two diagnostic methods (the golden standard and the diagnostic standard as serum TgAb level alone)were analyzed using McNemar test and measure of agreement Kappa. And, the analysis of positive likelihood ratio (+LR) with different threshold values were carried out in the study.

Statistical analyses were performed with SPSS for Windows Software package (Release 17.0, SPSS Inc., US).

3. Results

3.1. Serum TgAb Levels and Clinical Characteristics in the Two Groups

A total of 341 patients were enrolled and divided into two groups: 119 patients with recurrence group and 222 patients with NED group between January 2001 and December 2014. Table 1 summarizes the clinical characteristics of 341 patients. Age, sex and histology of recurrence group were compared with those of NED group respectively; no significant differences were all found (P > 0.05). Serum TgAb level was significantly higher in the patients with recurrence group in comparison with patients in NED group (1381.292 ± 1017.221 vs. 125.559 ± 314.047 IU/ml, P = 0.000 < 0.001). Medians of serum TgAb level were 1038.4000 IU/ml and 63.745 IU/ml in recurrence group and NED group, respectively.

Table 1. Characteristics of the study populations, according to study group.

*There was not statistically significant difference (χ2 = 2.457, P = 0.117 > 0.05). No significant difference was found (t = 1.454, P = 0.147 > 0.05). It was not statistically significant difference (χ2 = 5.229, P = 0.073 > 0.05). Serum thyroglobulin autoantibodies (TgAb) levels were significantly higher in the recurrence group as compared with that in the NED group (t = 13.135, P = 0.000 < 0.001). §Comparison of Recurrence Group vs. NED Group by Independent-Samples T Test. ††Comparison of Recurrence Group vs. NED Group by χ2 test.

3.2. Receiver Operating Characteristic Curve Analysis

Figure 1 showed nonparametric ROC curve of serum TgAb levels of the studied patients. ROC curve analysis showed the AUC of 0.962 which was significantly different

Figure 1. Nonparametric ROC curve of serum TgAb levels of the studied patients. The area under the curve (AUC) was 0.962. The area was significantly different from 0.5 (P = 0.000 < 0.001). Point A on the curve is the closest to the upper left corner. Its ordinate is 0.924, its abscissa is 0.077. If point A is defined as optimal operating point, corresponding to Sen and Spe are 92.40%, 92.30%, respectively.

from 0.5 (P = 0.000 < 0.001). The 95% CI for the area was (0.942, 0.982). The interval did not consist of 0.5.The results showed that serum TgAb level reflects the recurrence of DTC in TgTgAb+ patients after thyroid ablation successfully. Point A on the curve is the closest to the upper left corner. Its ordinate is 0.924, its abscissa is 0.077. If point A is defined as optimal operating point, corresponding to Sen and Spe are 92.40%, 92.30%, respectively.

3.3. Determining the Cut-Off Value

YI is an index of analysis by synthesis that reflects the authenticity of diagnostic test. It is defined as (Sen + Spe ? 1); its range is from −1 to +1. As the analysis of definite quantity, the closer the value is to the upper limit (+1), the higher the overall accuracy of the diagnostic test.

We selected the operating point on the ROC curve the closest to the upper left corner as cut-off point (point A showed Figure 1). Corresponding YI (0.847) is a maximum index. That is to say, the Sen/Spe pair maximizes the function [Sen − (1 ? Spe)]. Corresponding ordinate and abscissa are 0.924, 0.077 respectively (i.e., the predicted diagnostic Sen and Spe are 92.40%, 92.30% respectively). And, corresponding TgAb level is 246.695 IU/ml (point A showed Figure 2).

Figure 2. Line chart of Youden index by serum TgAb levels. The ordinate of point A on the curve is 0.847 (i.e., the maximum value of Youden index is 0.847), corresponding abscissa is 246.695 (i.e., serum TgAb level is 246.695 IU/ml). That is to say, the cut-off value of serum TgAb is 246.695 IU/ml.

3.4. Symmetric Measures

The symmetric measures of the two diagnostic methods (the golden standard and the diagnostic standard as serum TgAb level alone) were analyzed using McNemar test and measure of agreement Kappa. McNemar test showed that the diagnostic result of the two methods was not significant difference (P = 0.230 > 0.05). Agreement Kappa (κ) is a measurement of evaluating agreement of the diagnostic result of the two methods. Thus, κ ≥ 0.7 is considered to be excellent test results (i.e., the agreement of two diagnostic methods was high statistical significance); 0.4 ≤ κ < 0.7 is considered to be statistical significance; κ < 0.4 is considered to be no statistical significance. Measure results of agreement Kappa was “κ = 0.841, P = 0.000 < 0.001”, that showed the agreement of the two diagnostic methods was high statistical significance.

3.5. Diagnostic Properties and Analysis of Positive Likelihood Ratio

Selecting TgAb = 246.695 IU/ml as cut-off value, we predicted the studied patients (Table 2). Diagnostic properties were expressed by Sen, Spe, positive likelihood ratio (+LR), accuracy (Acc), positive predictive value (+PV) and negative predictive value (−PV). According to Table 2, we calculated +LR = 12.83 [(110/119)/(16/222)], Acc = 92.67% [(110 + 206)/341], +PV = 87.30% (110/126), −PV = 95.81% (206/215).

The analysis of +LR with different threshold values were calculated in the study (Table 3, Figure 3). Table 3 and Figure 3 showed that the higher serum TgAb level, the higher corresponding +LR was (i.e., the higher serum TgAb level, the more possible recurrence was). According to the relationship of pre-test odds, post-test odds, pre-test probability and post-test probability, we calculated the results as follows: when the pre-test probability fixed and except for the mixed function of other factors, the possibility of recurrence as TgAb ≥ 246.695 IU/ml was 10.294 times that of TgAb < 246.695 IU/ml; the possibility of recurrence as TgAb > 1000.000 IU/ml was 1.086 times that of 246.695 IU/ml ≤ TgAb ≤ 1000.000 IU/ml, 4.571 times that of 100.000 IU/ml ≤ TgAb <

Table 2. Comparison of the two diagnostic results.

Table 3. Positive likelihood ratios of different threshold values.

Figure 3. Positive likelihood ratio of different threshold value of serum TgAb. The serum TgAb levels were higher; the corresponding +LR was higher. That is to say, the higher serum TgAb levels, the more possible recurrence or metastases was.

246.695 IU/ml, 29.109 times that of 10.000 IU/ml ≤ TgAb < 100.000 IU/ml; the possibility of recurrence as 246.695 IU/ml ≤ TgAb ≤ 1000.000 IU/ml was 4.209 times that of 100.000 IU/ml ≤ TgAb < 246.695 IU/ml, 26.802 times that of 10.000 IU/ml ≤ TgAb < 100.000IU/ml; the possibility of recurrence as 100.000 IU/ml ≤ TgAb < 246.695 IU/ml was 6.368 times that of 10.000 IU/ml ≤ TgAb < 100.000 IU/ml.

According to the analysis of positive likelihood ratio, we assumed that the possibility of recurrence/metastases as 246.695 IU/ml ≤ TgAb < 1000.000 IU/ml is 10 units, the possibility of recurrence/metastases as TgAb > 1000.000 IU/ml, 100.000 IU/ml ≤ TgAb < 246.695 IU/ml and 10.000 IU/ml ≤ TgAb < 100.000 IU/ml is 10.860 units, 2.376 units, 0.373 units respectively (Figure 4).

4. Discussion

Self antigen of TgAb is TG. And, TG is incomplete “inaccessible antigen” and giant molecule glycoprotein synthesized by thyroid follicular epithelial cell. Serum TgAb is usually of IgG1, IgG3 or IgG4 subtypes in DTC patients [18] . Serum TG is an established tumor marker in monitoring recurrence patients with DTC [19] , but TgAb interference affects serum Tg measurement. Therefore, we should attach importance to the TgAb interference in serum Tg measurement for TgTgAb+ DTC patients. Some studies [10] - [15] [20] [21] reported elevated TgAb level may be representative of recurrence in TgTgAb+ DTC patients. That is, these kinds of patients were additionally diagnosed as recurrent or metastatic disease by measuring their serum TgAb levels. Some studies [22] [23] [24] [25] reported that production of TgAb is mainly due to intrathyroidal and extrathyroidal lymphocytes for antigen presentation to immune cells. Only rarely TgAb is produced by circulating lymphocytes and immune cells in cervical lymph nodes and bone marrow. This notion shows that the production of thyroid antibodies depends on antigenic components. After successful ablation of thyroid remnant tissue, the main source of TgAb is extrathyroidal lymphocytes. That is to say,

Figure 4. The possibility of recurrence/metastases as different threshold values of serum TgAb levels. Assuming the possibility of recurrence/metastases as 246.695 IU/ml ≤ TgAb < 1000.000 IU/ml is 10 units, the possibility of recurrence/metastases as TgAb > 1000.000 IU/ml, 100.000 IU/ml ≤ TgAb < 246.695 IU/ml and 10.000 IU/ml ≤ TgAb < 100.000 IU/ml is 10.860 units, 2.376 units, 0.373 units respectively.

persistent tumors mainly become source of antigenic components of producing TgAb. The notion theoretically explains that serum TgAb level is an index of recurrence or metastases in TgTgAb+ DTC patients of complete ablation.

In this study, we analyzed the diagnostic accuracy and ascertained the cut-off value of serum TgAb in the enrolled patients by means of ROC curve and +LR analysis of different threshold values. Serum TgAb levels (1381.292 ± 1017.221) IU/ml of patients with recurrence group was significantly higher than those (125.559 ± 314.047) IU/ml of NED group (P = 0.000) (Table 1), suggesting that serum TgAb level might be related to the persistence DTC. Similar findings have been reported previously [11] [15] . Hjiyi- annakis et al. [10] reported that 9 patients (22.5%) had shown progressively increasing TgAb levels and been confirmed recurrence diseases among 40 DTC patients with TGTgAb+. The result showed serum TgAb can indicate active tumor. Research results of most scholars [8] [9] [10] [11] [12] [15] showed that the retention of elevated TgAb levels appeared to act as “tumor marker” in the DTC patients with TGTgAb+. These notions provide practically reasons. But, it is controversial what its cut-off value of serum TgAb is. Only according to their clinical experience, most scholars [10] [11] [15] acted “TgAb = 100 U/ml, TgAb titre = 1/100, TgAb = 50 U/ml” as referential value that was not been statistically analyzed by diagnostic test.

According to our knowledge, this is the rare report on the application of ROC curve and +LR with different threshold values analyses in order to evaluate the diagnostic value of serum TgAb monitoring in the follow-up after successful ablation remnant thyroid tissue for TG-undetectable (TG) DTC patients. ROC curve is applied to evaluate the accuracy of diagnostic test. ROC curve occupy a central or unifying position in the process of assessing and using diagnostic tools. The ROC curve depicts the overlap between the two distributions by plotting the Sen vs. (1 − Spe) for the complete range of decision thresholds. The y-axis is Sen, and the x-axis is (1 − Spe). The ROC graph is a plot of all of the Sen/Spe pairs resulting from continuously varying the decision threshold over the entire range of results observed. Every point on the curve re- presents a Sen/Spe pair corresponding to a particular decision threshold [26] .

AUC is a measure of predicted accuracy. The results of our ROC study showed that AUC value was 0.956 (Figure 1). There was statistical difference between the AUC (0.956) and Az (0.5). And the AUC value (0.956) was higher than 0.9. The results showed that the diagnostic test was higher accuracy. That is to say, it was important diagnostic significance for serum TgAb level to evaluate recurrence in DTC patients of TGTgAb+. Even, it may be possible that TgAb is more likely to act as a tumor marker in these patients.

It showed that TgAb at a single cut-off level was used with regard to monitoring the recurrence of the DTC patients with TGTgAb+ received successful ablation. As showed in Figure 1 and Figure 2, we selected the “A” point of the closet to the upper left corner on the curve as cut-off point. Corresponding to YI is the maximum value (YI = 0.847). ROC analysis showed that the cut-off point (TgAb = 246.695 IU/ml) was the higher Sen (92.40%) and Spe (92.30%). And this may reflect the fact that 110 of 119 of the patients with recurrence had increased TgAb level (≥246.695 IU/ml) (Table 2). Only 7.56% (9/119) patients with recurrence were falsely classified as NED when the cut-off value revealed by ROC analysis was used (Table 2).

In the present study, the analytical results of +LR with different threshold values showed that the higher serum TgAb level, the more possible recurrence is (Table 3). The symmetric measures of the two diagnostic methods (the golden standard and the diagnostic standard as serum TgAb level alone) were carried out by use of McNemar test and measure of agreement Kappa. McNemar test estimated of the DTC recurrence for studied patients with acting “TgAb = 246.695 IU/ml” as cut-off value predicting results was compared with that for studied patients with clinical routine diagnostic methods predicting results. Statistically significant difference was not found (P = 0.230 > 0.05). Aside, measure of agreement Kappa shown that the two diagnostic methods is excellent symmetry (κ = 0.841 > 0.7, P = 0.000 < 0.05). The statistical results shown that it was high diagnostic value for predicting the studied patients with acting “TgAb = 246.695 IU/ml” as cut-off value. Serum TgAb level upon “246.695 IU/ml” may be associated with recurrent diseases.

Hjiyiannakis et al. [12] carried out a retrospective review to investigate the recurrence or metastases in patients with TgAb+ in the Royal Marsden Hospital. They reported that 11 patients were found recurrence among 28 patients of high titre group (TgAb > 1/100); only 2 patients were found recurrence among 12 patients of low titre group (TgAb < 1/100). Median of TgAb level was 1/604 in the high titre group, whereas it was 80 IU/ml in the low tire group. In our study, median of TgAb level was 1038.400 IU/ml in the recurrence group, and is similar to the observations of Hjiyiannakis et al. [12] . Our study shown that median of TgAb level only was 63.745 IU/ml in the NED group. Compared with the reported result by Hjiyiannakis et al. [12] , it was lower. In our study, serum TgAb levels were (1381.292 ± 1017.221) IU/ml in recurrence patients and (125.559 ± 314.047) IU/ml in NED patients. Compared with the observed results of Chung et al. [14] , the serum TgAb levels were similar in recurrence group and lower in NED group. This phenomenon is likely to be owing to the presence for following factors, such as selected patients, sample, different assay methods of serum TgAb and a TG/TgAb immune complex from the blood.

5. Conclusions

Serum TgAb is acted as a “tumor marker” and its cut-off value is 246.695 IU/ml in TGTgAb+ DTC patients with successful ablation of remnant thyroid tissue. The higher serum TgAb level, the more possible recurrence is. During the long follow-up of such patients populations, serum TgAb level should be routinely measured. As serum “TgAb ≥ 246.695 IU/ml”, correlative clinical measures should be carried out in order to find recurrence earlier and treating as soon as possible; as serum “TgAb < 246.695 IU/ml”, we should termly monitor the serum level of TgAb.

We need carry out a research of big sample and a long-term clinical observation to nail down the diagnostic value of serum TgAb in patients with DTC.

Acknowledgements

This study was supported by a grant from the National Natural Science Foundation of China (NSFC) (81071182).

Cite this paper

Fan, Q., Su, X.H. and Kuang, A.R. (2016) The Diagnostic Value of Serum TgAb in the Tg-Negative and TgAb-Positive DTC Patients after Successful Ablation. Journal of Cancer Therapy, 7, 889-900. http://dx.doi.org/10.4236/jct.2016.712086

References

  1. 1. Schlumberger, M.J. (1999) Diagnostic Follow-Up of Well-Differentiated Thyroid Carcinoma: Historical Perspective and Current Status. Journal of Endocrinological Investigation, 22, 3-7.

  2. 2. Mazzaferri, E.L. and Kloos, R.T. (2000) Using Recombinant Human TSH in the Management of Well-Differentiated Thyroid Cancer: Current Strategies and Future Directions. Thyroid, 10, 767-768.
    http://dx.doi.org/10.1089/thy.2000.10.767

  3. 3. Baloch, Z., Carayon, P., Conte-Devolx, B., et al. (2003) Laboratory Medicine Practice Guidelines: Laboratory Support for the Diagnosis and Monitoring of Thyroid Disease. Thyroid, 13, 3-126.
    http://dx.doi.org/10.1089/105072503321086962

  4. 4. Schneider, A.B. and Pervos, R. (1978) Radioimmunoassay of Human Thyroglobulin: Effect of Antithyroglobulin Antoantibodies. The Journal of Clinical Endocrinology & Metabolism, 47, 126-137.
    http://dx.doi.org/10.1210/jcem-47-1-126

  5. 5. Spencer, C.A. (2004) Challenges of Serum Thyroglobulin (Tg) Measurement in the Presence of Tg Autoantibodies. The Journal of Clinical Endocrinology & Metabolism, 89, 3702-3704.
    http://dx.doi.org/10.1210/jc.2004-0986

  6. 6. Locsei, Z., Szabolcs, I., Rácz, K., Kovács, G.L., Horváth, D. and Toldy, E. (2012) Serum Thyroglobulin Antibody Levels within or Near to the Reference Range May Interfere with Thyroglobulin Measurement. Biochemica Medica, 22, 365-370.
    http://dx.doi.org/10.11613/BM.2012.038

  7. 7. Spencer, C., Petrovic, I. and Fatemi, S. (2011) Current Thyroglobulin Autoantibody (TgAb) Assays Often Fail to Detect Interfering TgAb That Can Result in the Reporting of Falsely Low/Undetectable Serum Tg IMA Values for Patients with Differentiated Thyroid Cancer. The Journal of Clinical Endocrinology & Metabolism, 96, 1283-1291.
    http://dx.doi.org/10.1210/jc.2010-2762

  8. 8. Pacini, F., Mariotti, S., Formica, N., et al. (1988) Thyroid Autoantibodies in Thyroid Cancer: Incidence and Relationship with Tumour Outcome. Acta Endocrinologica, 119, 373-380.
    http://dx.doi.org/10.1530/acta.0.1190373

  9. 9. Rubello, D., Girelli, M.E., Casara, D., et al. (1990) Usefulness of the Combined Antithyroglobulin Antibodies and Thyroglobulin Assay in the Follow-Up of Patients with Differentiated Thyroid Cancer. Journal of Endocrinological Investigation, 13, 737-742.
    http://dx.doi.org/10.1007/BF03349612

  10. 10. Kumar, A., Shah, D.H., Shrihari, U., et al. (1994) Significance of Antithyroglobulin Autoantibodies in Differentiated Thyroid Carcinoma. Thyroid, 4, 199-202.
    http://dx.doi.org/10.1089/thy.1994.4.199

  11. 11. Spencer, C.A., Takeuchi, M., Kazarosyan, M., et al. (1998) Serum Thyroglobulin Autoantibodies: Prevalence, Influence on Serum Thyroglobulin Measurement, and Prognostic Significance in Patients with Differentiated Thyroid Carcinoma. The Journal of Clinical Endocrinology & Metabolism, 83, 1121-1127.

  12. 12. Hjiyiannakis, P., Mundy, J. and Harmer, C. (1999) Thyroglobulin Antibodies in Differentiated Thyroid Cancer. Clinical Oncology, 11, 240-244.
    http://dx.doi.org/10.1053/clon.1999.9056

  13. 13. Gorges, R., Maniecki, M., Jentzen, W., Sheu, S.N., Mann, K., Bockisch, A., et al. (2005) Development and Clinical Impact of Thyroglobulin Antibodies in Patients with Differentiated Thyroid Carcinoma during the First 3 Years after Thyroidectomy. European Journal of Endocrinology, 153, 49-55.
    http://dx.doi.org/10.1530/eje.1.01940

  14. 14. Chung, J.K., Park, Y.J., Kim, T.Y., et al. (2002) Clinical Significance of Elevated Level of Serum Antithyroglobulin Antibody in Patients with Differentiated Thyroid Cancer after Thyroid Ablation. Clinical Endocrinology, 57, 215-221.
    http://dx.doi.org/10.1046/j.1365-2265.2002.01592.x

  15. 15. Kucuk, O.N., Aras, G., Kulak, H.A., et al. (2006) Clinical Importance of Anti-Thyroglobulin Auto-Antibodies in Patients with Differentiated Thyroid Carcinoma: Comparison with 99mTc-MIBI Scans. Nuclear Medicine Communications, 27, 873-876.
    http://dx.doi.org/10.1097/01.mnm.0000243376.49378.27

  16. 16. Spencer, C.A., Bergoglio, L.M., Kazarosyan, M., Fatemi, S. and Lopresti, J.S. (2005) Clinical Impact of Thyroglobulin (Tg) and Tg Autoantibody Method Differences on the Management of Patients with Differentiated Thyroid Carcinomas. Journal of Clinical Endocrinology and Metabolism, 90, 5566-5575.
    http://dx.doi.org/10.1210/jc.2005-0671

  17. 17. Spencer, C.A. (2011) Clinical Review: Clinical Utility of Thyroglobulin Antibody (TgAb) Measurements for Patients with Differentiated Thyroid Cancers (DTC). Journal of Clinical Endocrinology and Metabolism, 96, 3615-3627.
    http://dx.doi.org/10.1210/jc.2011-1740

  18. 18. Caturegli, P., Kuppers, R.C., Mariotti, S., et al. (1994) IgG Subclass Distribution of Thyroglobulin Antibodies in Patients with Thyroid Disease. Clinical & Experimental Immunology, 98, 464-469.
    http://dx.doi.org/10.1111/j.1365-2249.1994.tb05514.x

  19. 19. Lubin, E., Mechlis-Frish, S., Zatz, S., et al. (1994) Serum Thyroglobulin and Iodine-131 Whole Body Scan in the Diagnosis and Assessment of Treatment for Metastatic Differentiated Thyroid Cancer. Journal of Nuclear Medicine, 35, 257-262.

  20. 20. Kim, E.S., Lim, D.J., Baek, K.H., Lee, J.M., Kim, M.K., Kwon, H.S., et al. (2010) Thyroglobulin Antibody Is Associated with Increased Cancer Risk in Thyroid Nodules. Thyroid, 20, 885-891.
    http://dx.doi.org/10.1089/thy.2009.0384

  21. 21. Rubello, D., Casara, D., Girelli, M.E., et al. (1992) Clinical Meaning of Circulating Antithyroglobulin Antibodies in Differentiated Thyroid Cancer: A Prospective Study. Journal of Nuclear Medicine, 33, 1478-1480.

  22. 22. Chiovato, L., Latrofa, F., Braverman, L.E., et al. (2003) Disappearance of Humoral Thyroid Autoimmunity after Complete Removal of Thyroid Antigens. Annals of Internal Medicine, 139, 346-351.
    http://dx.doi.org/10.7326/0003-4819-139-5_Part_1-200309020-00010

  23. 23. Weetman, A.P. and McGregor, A.M. (1994) Autoimmune Thyroid Disease: Further Developments in Our Understanding. Endocrine Reviews, 15, 788-830.
    http://dx.doi.org/10.1210/edrv-15-6-788

  24. 24. Mariotti, S., del Prete, G.F., Maggi, E., et al. (1984) Surface Markers and Function of Circulating Thyroid Autoantibody-Producing Cells. The Journal of Clinical Endocrinology & Metabolism, 58, 18-24.
    http://dx.doi.org/10.1210/jcem-58-1-18

  25. 25. Chiovato, L., Latrofa, F., Braverman, L.E., Pacini, F., Capezzone, M., Masserini, L., et al. (2003) Disappearance of Humoral Thyroid Autoimmunity after Complete Removal of Thyroid Antigens. Annals of Internal Medicine, 139, 346-351.
    http://dx.doi.org/10.7326/0003-4819-139-5_Part_1-200309020-00010

  26. 26. Zweig, M.H. and Campbell, G. (1993) Receiver-Operating Characteristic (ROC) Plots: A Fundamental Evaluation Tool in Clinical Medicine. Clinical Chemistry, 39, 561-577.