A Sputtering Deposition of Al Enhances the Output Reproducibility in a Conducting Rubber Force Sensor

Masato Ohmukai, Yasushi Kami

Department of Electrical and Computer Engineering, Akashi College of Technology, Akashi, Hyogo, Japan

Copyright © 2016 by authors and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY 4.0).

http://creativecommons.org/licenses/by/4.0/

Received: July 30, 2016; Accepted: August 16, 2016; Published: August 19, 2016

ABSTRACT

Compressive force sensors or pressure sensors are indispensable to tactile sensors in humanoid robots. It is investigated that low-cost electro-conducting rubber sheets are applied to the force sensor, of which the biggest problem is its poor reproducibility. It was found that the aluminum deposition by a vacuum evaporation method shows excellent characteristics but suffers deterioration by a radiation heating effect. The aluminum electrode was deposited by a sputtering method, known to have an advantage of a low-temperature method, and the reproducibility of the output was improved.

Keywords:

Conducting Rubber, Force Sensor, Electrode, Magnetron Sputtering, Reproducibility

1. Introduction

Tactile sensors are indispensable to humanoid robots, i.e. robot hands to pick up or to grasp an object. A humanoid robot is surely a kind of promising technology in the next stage of the robot field succeeded to present industrial robot technologies. Tactile sensors, which are undoubtedly in need to a sophisticated humanoid robot system, have been developed widely so far [1] - [4] . Some kinds of these sensors include strain gauge or piezo-resistive sensor arrays [5] - [7] for position sensing, as well as attractive sensors with capacitive or optical devices, organic transistors, ultrasonic or magneto-resistive devices, silicon-based microelectromechanical system (MEMS) and so on [8] - [37] .

Among many kinds of compressive force sensors, electro-conducting rubber sheet is available formidably at low cost. Even if the low-cost sensor is quite attractive, this material has been left to be ignored. It is partly because the reproducibility of the relationship between force and output voltage is not good enough. This problem should be solved in the future. Under these circumstances, many challenges are faced to realize a better sensor with the conducting rubber sheet. The attention is focused onto electrodes on the both sides of the rubber sheet, described as follows.

Four kinds of Al electrodes were investigated: Al foil just put on the surfaces, silver paste spread on the surfaces, electro-conducting tapes and Al deposited by a vacuum evaporation method. It was found that the last one exhibited the widest dynamic range and the good reproducibility in the force range of usual use as robot fingers [38] . Afterwards it was clarified the radiation heating of the rubber sheet deteriorated the reproducibility. Hence, the low-temperature deposition of Al is required to improve it [39] . In this article, the Al electrodes formed by a sputtering method were introduced and the advantages of them are inspected.

2. Experimental Details

Commercially available conductive rubber sheets (30 mm square and 15 μm thick) were used. Three kinds of metal contacts were used to the rubber sheets as a top electrode. In sample A, an Al thin film sheet (12 μm thick) was put on the top surface without anything between them, and the perimeter of the Al sheets were fixed with adhesive tape. Sample B consisted of the same parts as Sample A but the Al thin film was fixed to the rubber with electro-conducting epoxy glue between them. In Sample C, Al film was deposited (780 nm in thickness) using a magnetron sputtering apparatus. The deposition was performed for 3 hours with the input power of 50 W.

Each sample was put on an Al plate without anything on the bottom of the rubber sheet. Another Al plate was put on the top electrode in order to apply the force uniformly over the surface area. Weights of 100, 300 or 500 g were put on the top Al plate to apply a constant force to the sensor. The three kinds of weight correspond to the forces of 0.11, 0.33 and 0.54 N per 1 cm2, respectively. At least the last two values are in the region of normal finger manipulation, reportedly between 0.15 and 0.88 N [40] [41] .

The measurement system of the output voltage response to time is described here. The prepared detecting circuit for the sensor is shown in Figure 1. The r(t) denotes the

Figure 1. The detective circuit for the rubber sheet sensor (r).

resistance of the sensor that has several mega ohm without any force onto it and decreases down to the order of kilo ohm when the sensor is pressed by a finger. A resistor (R = 15 kΩ) and a capacitor (C = 4.7 μF) connected together in parallel was connected in series to the sensor, as shown in Figure 1 [38] . The output voltage Vo was taken across the added circuit elements. The capacitor works to reduce high frequency noise. The Vo was measured every 5 ms untill 1 s. This 1-s scan was repeated 100 times at each measurement.

3. Results and Discussion

Figures 2(a)-(c) show the time response of Vo when the weight of 100 g was put on the Sample A, B and C, respectively. Figure 3 and Figure 4 are the similar experimental results for the weights of 300 and 500 g, respectively.

Generally speaking, the output voltage of Vo is settled down in nearly 0.4 s in all cases except for Figure 3(b). In Figure 3(b), Vo is not settled down enough until 0.6 s. It probably stems from the plasticity of electro-conducting epoxy glue. Samples A and C are free from the disadvantage because Al is directly contacted to the rubber surface.

The final values of Vo is considered here. All the three samples have shown monotonic increase of Vo with respect to applied weight. The main concern is the relatively large errors of the final value. This is the case in all samples and noticeable in the case of 100 g. Fortunately in the region of usual manipulation, namely 300 and 500 g in our experiment, the relative error was lowered. In order to discuss the relative error, the dependence of the relative error is on the applied weight is shown in Figure 5. The figure apparently shows the relative error decreases with the applied weight in all samples. The tendency is convenient for the application to manipulation fingers because it meet the human sense.

The next issue is on the difference between the three samples. Figure 5 shows that Sample A gave the largest relative error in the three. It is natural because Al foil and rubber surface were not fixed to contact each other except for the peripheries. In both samples B and C, on the other hand, Al electrode is adhered closely to rubber surface microscopically. It was found that Sample C shows the smaller relative error than Sample B over 100 g. As a result, Sample C is most applicable for a practical use.

The error in the final value is discussed here. In all cases the error is characterized by the independence of time, or tends to take a constant value in one scan of measurement. The value is different at each scan. This fact derived from the inherent property of the conducting rubber that microscopic deformation of the molecules in the rubber is not the same at each scan. The discrepancy of the force can be detected if the difference of Vo is larger than the error. So Sample C is the most suitable in the three. One idea to suppress the error further, is taking an average of the final value of many scans. It might be realized in such a way that alternate actuation is applied for averaging. But it takes several seconds for obtaining the average. We expect to develop, in the future, a kind of methods to estimate the final value earlier than 0.4 s to reduce the time to obtain the average value.

(a) (b) (c)

Figure 2. (a) The time response of the output voltage: 100 g, sample A; (b) The time response of the output voltage: 100 g, sample B; (c) The time response of the output voltage: 100 g, sample C.

(a)(b)(c)

Figure 3. (a) The time response of the output voltage: 300 g, sample A; (b) The time response of the output voltage: 300 g, sample B; (c) The time response of the output voltage: 300g, sample C.

(a)(b)(c)

Figure 4. (a) The time response of the output voltage: 500 g, sample A; (b) The time response of the output voltage: 500 g, sample B; (c) The time response of the output voltage: 500 g, sample C.

Figure 5. Relative errors reduce with the applied weight. It shows at the same time that Sample C comparatively gives small error in general.

We are now returned to consider the final value of Vo. The dependence of the average of 100-times experimental results of the final value of Vo is shown in Figure 6 as a function of the applied weight. It is interesting to point that Samples A and C shows a convex property where Sample B shows a concave one. The convex property is more close to the logarithmic characteristics that is well known to fit to human’s sense, namely the Weber-Fechner’s theory, famous in a psychophysics field. In other words, the deviation from a linear relation works as a more human like behavior. Comparing the two samples A and C tells us that Sample C is more sensitive than Sample A. The higher sensitivity can provide the higher identification ability of the force from Vo. We conclude that Sample C is most applicable in the three from the point of view in Figure 6.

4. Conclusion

In this article, the characteristics of the output voltage from the force sensor of conducting rubber at the aim of application for low-cost sensors were studied. Three kinds of electrodes were investigated: Al foil just put on the rubber (Sample A), Al foil stuck to the rubber with electro-conducting epoxy glue between them (Sample B), and Al deposited by means of a sputtering method (Sample C). It was concluded that Sample C showed the most excellent characteristics in the three; the relative error is the smallest and the relationship between the output voltage and applied force shows a convex feature, so more likely to be logarithmic, which is close to the human sense as is well known as Weber-Fechner’s theory. In addition, the high sensitivity in a small force region can contribute to the better estimation of the applied force. The conducting rubber gives inevitable error in final output voltage derived from its inherent property. It is surely a great challenge to reduce the error further with the help of the estimation of final value in a short time.

Figure 6. The dependence of the weight loaded on the rubber sheet sensor on the output voltage Vo. The signs A, B and C refer to Sample A, B and C, respectively.

Acknowledgements

The authors are grateful to K. Ashida for their help in the measurements. This work was partially supported by a Grant-in-Aid for Scientific Research No. 16K01430 from the Ministry of Education Science, Sports, and Culture, for which the authors are grateful.

Cite this paper

Ohmukai, M. and Kami, Y. (2016) A Sputtering Deposition of Al Enhances the Output Reproducibility in a Conducting Rubber Force Sensor. Journal of Sensor Technology, 6, 46-55. http://dx.doi.org/10.4236/jst.2016.63004

References

  1. 1. Lee, M.H. and Nicholls, H.R. (1999) Review Article Tactile Sensing for Mechatronics—A State of the Art Survey. Mechatronics, 9, 1-31.
    http://dx.doi.org/10.1016/S0957-4158(98)00045-2

  2. 2. Li, Z., Hsu, P. and Sastry, S. (1989) Grasping and Coordinated Manipulation by a Multifingered Robot Hand. International Journal of Robotics Research, 8, 33-50.
    http://dx.doi.org/10.1177/027836498900800402

  3. 3. Berger, A.D. and Khosla, P.K. (1991) Using Tactile Data for Real-Time Feedback. International Journal of Robotics Research, 10, 88-102.
    http://dx.doi.org/10.1177/027836499101000202

  4. 4. Schmidt, P.A., Mael, E. and Wurtz, R.P. (2006) A Sensor for Dynamic Tactile Information with Applications in Human-Robot Interaction & Object Exploration. Robotics and Autonomous Systems, 54, 1005-1014.
    http://dx.doi.org/10.1016/j.robot.2006.05.013

  5. 5. Kim, K., Lee, K.R., Kim, W.H., Park, K., Kim, T., Kim, J. and Pak, J.J. (2009) Polymer-Based Flexible Tactile Sensor up to 32 × 32 Arrays Integrated with Interconnection Teminals. Sensors and Actuators A: Physical, 156, 284-291.
    http://dx.doi.org/10.1016/j.sna.2009.08.015

  6. 6. Engel, J., Chen, J. and Liu, C. (2003) Development of Polyimide Flexible Tactile Sensor Skin. Journal of Micromechanics and Microengineering, 13, 359-366.
    http://dx.doi.org/10.1088/0960-1317/13/3/302

  7. 7. Zhang, Y. (2010) Sensitivity Enhancement of a Micro-Scale Biomimetic Tactile Sensor with Epidermal Ridges. Journal of Micromechanics and Microengineering, 20, 085012.
    http://dx.doi.org/10.1088/0960-1317/20/8/085012

  8. 8. Choi, W.-C. (2010) Polymer Micromachined Flexible Tactile Sensor for Three-Axial Toads Detection. Transactions on Electrical and Electronic Materials, 11, 130-133.
    http://dx.doi.org/10.4313/TEEM.2010.11.3.130

  9. 9. Noda, K., Hoshino, K., Matsumoto, K. and Shimoyama, I. (2006) A Shear Stress Sensor for Tactile Sensing with the Piezoresistive Cantilever Standing in Elastic Material. Sensors and Actuators A: Physical, 127, 295-301.
    http://dx.doi.org/10.1016/j.sna.2005.09.023

  10. 10. Beccai, L., Rocdella, S., Ascari, L., Valdastri, P., Sieber, A., Carrozza, M. and Dario, P. (2008) Development and Experimental Analysis of a Soft Compliant Tactile Microsensor for Anthropomorphic Artificial Hand. IEEE/ASME Transactions on Mechatronics, 13, 158-168.
    http://dx.doi.org/10.1109/TMECH.2008.918483

  11. 11. Lee, H., Chung, J., Chang, S. and Yoon, E. (2008) Normal and Shear Force Measurement Using a Flexible Polymer Tactile Sensor with Embedded Multiple Capacitors. Journal of Microelectromechanical Systems, 17, 934-942.
    http://dx.doi.org/10.1109/JMEMS.2008.921727

  12. 12. Miyazaki, S. and Ishida, A. (1984) Capacitive Transducer for Continuous Measurement of Vertical Foot Force. Medical & Biological Engineering & Computing, 22, 309-316.
    http://dx.doi.org/10.1007/BF02442098

  13. 13. Hasegawa, Y., Shikida, M., Ogura, D., Suzuki, Y. and Sato, K. (2008) Fabrication of a Wearable Fabric Tactile Sensor Produced by Artificial Hollow Fiber. Journal of Micromechanics and Microengineering, 18, 085014.
    http://dx.doi.org/10.1088/0960-1317/18/8/085014

  14. 14. Heo, J.-S., Chung, J.-H. and Lee, J.-J. (2006) Tactile Sensor Arrays Using Fiber Bragg Grating. Sensors and Actuators A, 126, 312-327.
    http://dx.doi.org/10.1016/j.sna.2005.10.048

  15. 15. Cheung, E. and Lumelsky, V.L. (1992) A Sensitive Skin System for Motion Control of Robot Arm Manipulators. Robotics and Autonomous Systems, 10, 9-32.
    http://dx.doi.org/10.1016/0921-8890(92)90012-N

  16. 16. Kolesar, E.S., Reston, R.R., Ford, D.G. and Fitch, R.C. (1992) Multiplexed Piezoelectric Polymer Tactile Sensor. Journal of Field Robotics, 9, 37-63.
    http://dx.doi.org/10.1002/rob.4620090104

  17. 17. Dargahi, J., Parameswaran, M. and Payandeh, S. (2000) A Micromachined Piezoelectric Tactile Sensor for an Endoscopic Grasper—Theory, Fabrication and Experiments. Journal of Microelectromechanical Systems, 9, 329-335.
    http://dx.doi.org/10.1109/84.870059

  18. 18. Flanagan, J.R. and Wing, A.M. (1993) Modulation of Grip Force with Load Force during Point-to-Point Arm Movements. Experimental Brain Research, 95, 131-143.
    http://dx.doi.org/10.1007/BF00229662

  19. 19. Dario, P. and de Rossi, D. (1985) Tactile Sensors and Gripping Challenge. IEEE Spectrum, 22, 46-52.
    http://dx.doi.org/10.1109/MSPEC.1985.6370785

  20. 20. Wettels, N., Santos, V., Johansson, R. and Loeb, G. (2008) Biomimetric Tactile Sensor Array. Advanced Robotics, 22, 829-849.
    http://dx.doi.org/10.1163/156855308X314533

  21. 21. Manunza, I. and Bonfiglio, A. (2007) Pressure Sensing Using a Completely Flexible Organic Transistor. Biosensors and Bioelectronics, 22, 2775-2779.
    http://dx.doi.org/10.1016/j.bios.2007.01.021

  22. 22. Sekitani, T. and Someya, T. (2010) Stretchable, Large-Area Organic Electronics. Advanced Materials, 22, 2228-2246.
    http://dx.doi.org/10.1002/adma.200904054

  23. 23. Bloor, D., Donnelly, K., Hands, P.J., Laughlin, P. and Lussey, D. (2005) A Metal-Polymer Composite with Unusal Properties. Journal of Physics D: Applied Physics, 38, 2851-2860.
    http://dx.doi.org/10.1088/0022-3727/38/16/018

  24. 24. Maheshwari, V. and Saraf, R.F. (2006) High-Resolution Thin-Film Device to Sense Texture by Touch. Science, 312, 1501-1504.
    http://dx.doi.org/10.1126/science.1126216

  25. 25. Ando, S. and Shinoda, H. (1995) Ultrasonic Emission Tactile Sensing. IEEE Control Systems Magazine, 15, 61-69.
    http://dx.doi.org/10.1109/37.341866

  26. 26. Dahiya, R.S., Valle, M. and Lorenzelli, L. (2009) Spice Modelof Lossy Piezoelectric Polymers. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 56, 387-396.
    http://dx.doi.org/10.1109/TUFFC.2009.1048

  27. 27. Krishna, G.M. and Rajanna, K. (2004) Tactile Sensor Based on Piezoelectric Resonance. IEEE Sensors Journal, 4, 691-697.
    http://dx.doi.org/10.1109/JSEN.2004.833505

  28. 28. Nelson, T.J., Dover, R.B.V., Jin, S., Hackwood, S. and Beni, G. (1986) Shear-Sensitive Magnetroresistive Robotic Tactile Sensor. IEEE Transactions, 22, 394-396.
    http://dx.doi.org/10.1109/TMAG.1986.1064386

  29. 29. Wen, Z., Wu, Y., Zhang, Z., Xu, S., Huang, S. and Li, Y. (2003) Development of an Integrated Vacuum Microelectronic Tactile Sensor Array. Sensors and Actuators A, 103, 301-306.
    http://dx.doi.org/10.1016/S0924-4247(02)00392-8

  30. 30. Beebe, D.J., Hsieh, A.S., Denton, D.D. and Radwin, R.G. (1995) A Silicon Force Sensor for Robotics and Medicine. Sensors and Actuators A, 50, 55-65.
    http://dx.doi.org/10.1016/0924-4247(96)80085-9

  31. 31. Wolffenbuttel, M.R. and Regtien, P.P.L. (1991) Polysilicon Bridges for the Realization of Tactile Sensors. Sensors and Actuators A, 26, 257-264.
    http://dx.doi.org/10.1016/0924-4247(91)87002-K

  32. 32. Sugiyama, S., Kawahata, K., Yoneda, M. and Igarashi, I. (1990) Tactile Image Detection Using a 1K-Element Silicon Pressure Sensor Array. Sensors and Actuators A, 22, 397-400.
    http://dx.doi.org/10.1016/0924-4247(89)80001-9

  33. 33. Liu, L., Zheng, X. and Li, Z. (1993) An Array Tactile Sensor with Piezoresistive Single-Crystal Silicon Diaphragm. Sensors and Actuators A, 35, 193-196.
    http://dx.doi.org/10.1016/0924-4247(93)80151-6

  34. 34. Kane, B.J., Cutkosky, M.R. and Kovacs, G.T.A. (2000) A Traction Stress Sensor Array for Use in High-Resolution Robotic Tactile Imaging. Journal of Microelectromechanical Systems, 9, 425-434.
    http://dx.doi.org/10.1109/84.896763

  35. 35. Takao, H., Sawada, K. and Ishida, M. (2006) Monolithic Silicon Smart Tactile Image Sensor with Integrated Strain Sensor Array on Pneumatically Swollen Single-Diaphragm Structure. IEEE Transactions on Electron Devices, 53, 1250-1259.
    http://dx.doi.org/10.1109/TED.2006.872698

  36. 36. Chu, Z., Saoor, P.M. and Middelhoek, S. (1996) Silicon Three-Axial Tactile Sensor. Sensors and Actuators A, 54, 505-510.
    http://dx.doi.org/10.1016/S0924-4247(95)01190-0

  37. 37. Leineweber, M., Pelz, G., Schmidt, M., Kappert, H. and Zimmer, G. (2000) New Tactile Sensor Chip with Silicone Rubber Cover. Sensors and Actuators A, 84, 236-245.
    http://dx.doi.org/10.1016/S0924-4247(00)00310-1

  38. 38. Ohmukai, M., Kami, Y. and Matsuura, R. (2012) Electrode for Force Sensor of Conductive Rubber. Journal of Sensor Technology, 2, 127-131.
    http://dx.doi.org/10.4236/jst.2012.23018

  39. 39. Ohmukai, M., Kami, Y. and Ahida, K. (2013) Conducting Rubber Force Sensor: Transient Characteristics and Radiation Heating Effect. Journal of Sensor Technology, 3, 36-41.
    http://dx.doi.org/10.4236/jst.2013.33007

  40. 40. LaMotte, R.H. and Srinivasan, M.A. (1987) Tactile Discriminationof Shape: Responses of Slowly Adapting Mechanoreceptive Afferents to a Step Stroked across the Monkey Fingerpad. Journal of Neuroscience, 7, 1655-1671.

  41. 41. LaMotte, R.H. and Srinivasan, M.A. (1987) Tactile Discriminationof Shape: Responses of Rapidly Adapting Mechanoreceptive Afferents to a Step Stroked across the Monkey Fingerpad. Journal of Neuroscience, 7, 1672-1681.