Smart Grid and Renewable Energy
Vol.09 No.04(2018), Article ID:85331,17 pages
10.4236/sgre.2018.94005

Energy Characteristics of an Integrated Power Generation System with Photovoltaic and Fuel Cell

Akira Nishimura1, Syota Tanikaga1, Masafumi Hirota1, Eric Hu2

1Division of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, Japan

2School of Mechanical Engineering, The University of Adelaide, Adelaide, Australia

Copyright © 2018 by authors and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY 4.0).

http://creativecommons.org/licenses/by/4.0/

Received: April 2, 2018; Accepted: April 27, 2018; Published: April 30, 2018

ABSTRACT

An integrated energy system (with photovoltaic (PV) and fuel cell (FC) for building) is proposed and assessed in term of its energy self-sufficiency rate in seven cities (Nagoya, Toyota, Tajimi, Takayama, Ogaki, Hamamatsu, Shizuoka) in Tokai region in Japan in this paper. In this work, it is considered that the electricity requirement of the building for household users is provided by a building integrated photovoltaic (BIPV) system and the gap between the energy demand and BIPV supply is fulfilled by the FC. The FC is powered by the electrolytic H2 produced when PV power was in surplus. Based on the study of applying the proposed system in seven cities, which clarifies the effectiveness of the integrated BIPV, electrolytic H2 and FC power generation system, a universal system model has been developed in this paper. It has been observed that the monthly power production from BIPV as well as FC system are higher in spring and summer, while they are both lower in autumn and winter at all considered locations. The self-sufficiency rate of the FC system is higher with decreasing households’ number and it has been observed that 16 is the most appropriate number of households in a building, whose electricity demand could be fully covered by the integrated PV and FC system. Due to its climate condition, Hamamatsu is the best city in the region for installing the proposed system. The correlation between the households’ number and self-sufficiency rate of the FC system per solar PV installation area can be expressed by the regression curve in the form of y = ax−b well.

Keywords:

Smart Building, Photovoltaics, H2 Produced by Water Electrolysis, Polymer Electrolyte Fuel Cell, Self-Sufficiency Rate

1. Introduction

According to Energy White Paper 2017 in Japan [1] , it is expected that the global consumption of primary energy will increase by 1.2% - 1.8% per year from 2015 to 2030. The renewable energy is expected to be the most increasing energy source. Power generated from renewable energy sources excluding hydro power in 2030 is expected to be 2.1 - 3.4 times as large as that in 2015. Though the renewable energy such as solar photovoltaic (PV) has been growing rapidly due to feed-in tariff system introduced in 2012 in Japan, the ratio of the installed capacity as well as the electricity generated of PV system in Japan to those in the world becomes lower. In other words, the growth of renewable energy in Japan is lower than world average. To promote the growth of renewable energy (in Japan), it is important to develop the low cost technology and to solve the problem that the output is unsteadiness due to their intermittent natures.

Recently, the so-called building integrated PV systems (BIPV) have been attracted attention from the world [2] [3] . Systems are integrating/installing solar panels on the roof and/or side walls of a building to meet the energy demand of the building. The studies on power generation characteristics or economy assessment of BIPV considering the climate condition in Singapore [4] , Malaysia [5] and Brazil [6] were reported. In addition, the environmental assessment by Life Cycle Assessment of BIPV was also reported [7] [8] [9] . The combined system of BIPV and battery for solving the performance fluctuation of PV due to weather was evaluated from the view point of power generation performance and economy characteristics [10] [11] . It was reported that the conversion into H2 is superior to battery to store the large amount of renewable energy for a long time [12] , and there were some reports investigating the combination of PV and electrolytic H2 [13] [14] . Although there were a few research investigating the combination of BIPV, electrolytic H2 and fuel cell power generation system [15] [16] [17] , they mainly focused on the system control procedure such as the evaluation on dynamics characteristics of system output [15] , the optimization of system output [16] and the evaluation of fussy control effectivity [17] . Therefore, there were few studies other than the authors’ group that investigate the power generation characteristics considering the size of the building and climate conditions in the building locations to meet the electricity demand [18] . However, the previous study [18] investigated for only limited cities in one prefecture (in Japan), resulting that the more case studies are needed for clarifying the effectiveness of the combination of BIPV, electrolytic H2 and fuel cell (FC) power generation system and for developing the universal system model.

In this paper, a desk top case study has been performed to simulate a proposed BIPV system with utilization of stored energy in the form of electrolytic H2 and the stored H2 is used to fuel FC to generate the power for a building when the power generated from the BIPV is insufficient for the building. The proposed integrated BIPV + FC system consists of the solar PV array, water electrolyzer and FC. The H2 is generated and stored with the surplus power of the BIPV. The FC would therefore be able to buffer the intermittency (partly) between the building electricity demand (by the building) and the PV system. To investigate the impact of local climate condition on the performance of the proposed integrated system, two cities in Aichi prefecture (Nagoya, Toyota), three cities in Gifu prefecture (Tajimi, Takayama, Ogaki) and two cities in Shizuoka prefecture (Hamamatsu, Shizuoka) in Tokai region, Japan have been selected to the locations for the desk-top case study. Their meteorological data are from the project “PV300” (period from August, 2013 to July, 2014) [19] . The BIPV power productions have been compared with the electricity demand data of households [20] and investigated for the optimum power supply in a way to overcome the intermittency of the electricity demand and PV system. The self-sufficiency rate of the proposed BIPV system to electricity demand has been estimated in the design study. In addition, the optimum number of households living in the building, i.e. the optimum size of the building, has been investigated. From the results of this study, the universal BIPV system model which can be applied for different climate conditions is obtained. This can be contributed for promoting the growth of renewable energy.

2. Design Study

2.1. Estimation of Power Generation from the PV System

The building model, used in the design study, is 10 m width, 40 m length and 40 m height (=10 stories) [21] with 40 households [22] . According to the statistics data collected in Japan [22] , the average floor space of dwelling of Japan is about 100 m2 per a household. The height of one floor is assumed as 4 m. Assuming that four households stay per floor, the floor space is 400 m2. This study proposed the building model utilizing the accelerated wind between buildings for a power generation by wind turbine and assessed the power generation performance of wind turbine of 50 kW class whose height was 39 m [21] . Since this study considers the application of this building model for combining with PV system in the future, the building size of 10 m width, 40 m length and 40 m height is set at the initial condition. The BIPV system has considered on the roof/top of the building, i.e., with 400 m2 areas, and a FC using electrolytic H2 produced when there is the surplus power from BIPV [23] .

The power generated by PV system is calculated by using the following equation [24] :

E P V = H × K × P / 1 (1)

where EPV is hourly electric power of PV system (kW∙h), H is hourly amount of solar radiation (kW∙h/m2), K is power generation loss factor (−), P is system capacity of PV (kW), 1 is solar radiation under standard state (AM1.5, hourly solar radiation: 1 kW∙h/m2, module temperature: 25 degree Celsius) (kW/m2). The instantaneous solar radiation data by 10 sec of the reference [19] are integrated as hourly data for calculating the hourly electric power of PV system.

In this study, the high-performance PV P250α Plus produced by Panasonic has been considered. This module has conversion efficiency and maximum power rating per module is 19.5% and 250 W [25] . The size of PV module is 1580 mm × 812 mm × 35 mm. P has been calculated by installing this PV module on the roof of the building model, which is 75 kWp (=300 solar modules). To calculate K, the performance value of state-of-the-art commercial devise is used. K is calculated by using the following equation [24] :

K = K p × K m × K i (2)

where Kp is power conversion efficiency of power conditioner (−), Km is correction factor decided by module temperature (−), Ki is power generation loss by interconnecting and dirty of module surface (−). In this study, Kp and Ki are set at 0.96 and 0.95, respectively. Kp is assumed by referring to the performance of commercial power conditioning device VBPC259B3 manufactured by Panasonic [26] . Km is calculated by the following equation [24] :

K m = 1 ( T m T s ) C 100 (3)

where Tm is PV module temperature (degree Celsius), Ts is temperature under standard test condition (= 25 degree Celsius) (degree Celsius), C is temperature correction factor which is 0.35 [27] (%/degree Celsius). The temperature characteristics of PV module which is adopted for this study is referred. Tm is calculated by using the following equation [24] [28] :

T m = T a + ( 46 0.41 U m 0.8 + 2 ) H 2 (4)

where Ta is ambient air temperature (degree Celsius), Um is wind velocity over module of PV (m/s). In this equation, the convection heat transfer by wind around the PV module is considered.

The meteorological data, such as solar radiation, the ambient air temperature, and wind velocity of the cities involved in the study have been taken from the data base of the project “PV300” for the period from August, 2013 to July, 2014 [19] . Table 1 has listed a sample of PV300 data, which shows the data of air temperature and amount of horizontal solar radiation at 10 sec intervals on 1st August, 2013 for Nagoya in Japan. According to the previous study [24] , the optimum tilt angle of solar panel installed on a roof/top of the building is 0 degree, resulting that the horizontal solar radiation has been used for calculating the power generated by the PV system in this study.

2.2. Estimation of Power Generated by FC System Using H2 Produced by Water Electolysis

In this study, it has been assumed that the surplus power generated by the PV system over the electricity demand of households [20] living in the considered building, would be used for electrolytic H2 production (i.e. long term energy storage in the form of electrolytic H2). To optimize the size of BIPV system,

Table 1. Sample data of PV300 on 1st August, 2013 for Nagoya in Japan.

number of households has been varied by 40, 20, 16 and 12 which correspond to 10, 5, 4 and 3 stories of the building, respectively. In this study, the building which has 4 households per floor is assumed. Then, the multiple number of 4 is based for assessment. To keep a building structure, the lowest limit of stories is set at 3 which is the standard low height building, indicating 12 households. The Type-S electrolyzer manufactured by IHT [29] [30] whose H2 production rate, power consumption and electrolysis efficiency are 760 N∙m3/h, 4.45 kW∙h/N∙m3 and 79.5%, have been used in this design study. The amount of electrolytic H2 could be produced by the surplus power generated from the PV system is calculated by the following equation:

V H 2 = E s / P e (5)

where VH2 is amount of electrolytic H2 produced (N∙m3), Es is surplus power generated by PV system (kW∙h), Pe is power consumption (kW∙h/N∙m3). In this study, it is assumed that the electrolyzer can be operated following the power generation characteristics of PV system every time and the produced H2 can be stored as well as used instantaneously [24] .

It has been assumed that the H2 produced by the electolyzer would be used to generate power through a polymer electrolyte fuel cell (PEFC) system [24] . H2 is converted into electricity by FC following the below equation:

H 2 + 1 / 2 O 2 = H 2 O + η f Q (6)

where ηf is power generation efficiency of latest PEFC stationary system based on lower heating value (= 0.39) [31] , Q is lower heating value of H2 (=242) (kJ/mol). It is assumed that the energy loss for operating pump to preserve and provide gases is ignored [18] . Figure 1 illustrates the schematic drawing of the proposed integrated BIPV + FC system.

In this study, a monthly self-sufficiency rate of the proposed combination system consisting of the PV and FC has been investigated for Nagoya (Latitude: 35.10˚N, Longitude: 136.54˚E), Toyota (Latitude: 35.4˚N, Longitude: 137.9˚E), Tajimi (Latitude: 35.19˚N, Longitude: 137.7˚E), Takayama (Latitude: 36.8˚N, Longitude: 137.15˚E), Ogaki (Latitude: 35.21˚N, Longitude: 136.36˚E), Hamamatsu (Latitude: 34.42˚N, Longitude: 137.43˚E) and Shizuoka (Latitude: 34.54˚N, Longitude: 138.18˚E). They are the main cities in Tokai region located in the center of Japan. The self-sufficiency rate is defined as the power supplied (from the combined PV and FC system) to the electricity demand of the households living in the building. The hourly time change in the self-sufficiency rate in the day, when the daily mean amount of horizontal solar radiation per month has been obtained and estimated.

3. Results and Discussion

3.1. Power Supply Characteristics of the BIPV to the Building Electricity Demand in the Case of 40 Households

This study has investigated the power production from the PV system using the meteorological data base of PV300 [19] including air temperature, solar intensity and wind speed at 10 sec intervals. Since the electricity demand of households [20] is available as hourly data, the power production from the PV system is

Figure 1. Schematic drawing of the proposed integrated BIPV + FC system.

summarized as hourly data by integrating the instantaneous data available at 10 sec intervals.

As an example, Table 2 has listed the hourly power from PV system (installed in Nagoya for a year) which shows the seasonal characteristic of the PV system. From this table, it can be seen the hourly power of PV system increases from the morning up to the noon and decreases from the noon up to the evening as expected. In addition, it is obvious that the hourly power of PV system is higher in spring and summer, while it is lower in autumn and winter. The data shown in the Table 2 has been summed as the typical daily data for the location in the month which then is multiplied by the total days for each month as the monthly data. The monthly power production from the PV system is shown in Figure 2 to investigate the seasonal and local characteristics. It has been observed that the monthly power of the PV system is higher in spring and summer, while it is lower in autumn and winter irrespective of the cities. According to the comparison among seven cities, the monthly power of the PV system from November to January in Takayama is smaller than that in the other cities. In addition, the monthly power of the PV system for Hamamatsu is high through the year. The reasons will be discussed later.

Table 3 has listed the hourly electricity demand of 40 households for a year. In this study, the variation of electricity demand profile for different cities is not considered like the previous study [18] . Namely, the same electricity demand profile has been used for all seven cities in this study. When considering the electricity demand profile of other number of households, the data in Table 3 have been recalculated. It is found that the hourly electricity demand increases from the morning and keeps almost a constant value during a day. After that, the hourly electricity demand increases rapidly from the evening and keeps almost a

Figure 2. Monthly power of PV system assumed to be installed in seven cities.

Table 2. Hourly power of PV system assumed to be installed in Nagoya for a year (Unit: kW∙h).

constant value up to the midnight. In addition, it is obvious that the electricity demand is higher in summer and winter, especially at the night in summer. However, it is lower in spring and autumn.

Figure 3 has shown the monthly self-sufficiency rate of the FC system in the 40 house case. The self-sufficiency rate is calculated by dividing the power produced by the FC system by the electricity demand, which is not covered by the PV system. Here, the power produced by the FC system has been calculated by using the surplus power of PV system and the Equations (5) and (6). If the self-sufficiency rate of the FC system is over 100%, the proposed integrated system can cover the electricity demand of households living in the building. In this

Table 3. Hourly electricity damand data of 40 households (Unit: kW∙h).

study, it has been assumed that the surplus power of PV system is used to electrolyze water and the H2 produced is stored for fueling the FC to make up the shortage of power during the required time.

According to Figure 3, the monthly power of the FC system is higher in spring and summer, while it is lower in autumn and winter irrespective of cities. It can be considered that the power generation characteristics of FC system follows the power generation profile of the PV system. In addition, it has been seen from Figure 3 that the monthly self-sufficiency rate of the FC system is below 100% irrespective of the cities. Therefore, the proposed BIPV + FC system is not able to cover completely the electricity demand of 40 households living in the building.

Figure 3. Monthly self-sufficiency rate of the FC system assumed to be installed in seven cities(40 households’ case).

3.2. Optimum Households’ Number for Proposed BIPV + FC System to Meet Electricity Demand Completely

The households’ number is changed to investigate the proper households’ number for same installment area of solar array on the roof/top of building. Figures 4-6 have shown the monthly self-sufficiency rate of FC system assumed to be installed in Nagoya, Toyota, Tajimi, Takayama, Ogaki, Hamamatsu and Shizuoka for 20, 16 and 12 households’ cases, where the stories of buildings are 5, 4 and 3, respectively. Figures 7-9 show the monthly mean temperature, mean wind velocity and sunshine hours [32] whose date and time followed the data base of the project “PV300” [19] , respectively.

It can be seen from Figures 4-6, the self-sufficiency rate of FC system is higher with decreasing households’ number. This is because that the surplus power of PV system increases with decreasing households’ number, i.e., decreasing electricity demand. In addition, the self-sufficiency rate of FC system can be over 100% in spring and summer while that is below in autumn and winter. This trend matches with the power generation characteristic of PV system. Though the electricity demand increases in summer, the power of PV system seems to be sufficient, resulting in the high self-sufficiency rate of FC system in summer. Comparing seven cities, the self-sufficiency rate of FC system from November to January in Takayama is lower than that in the other cities. Since Takayama has a lot of snow in winter which can be explained by short sunshine hours shown in Figure 9, resulting that the power generated from the PV system is smaller compared to the other cities. Though the monthly mean temperature in winter is lower in Takayama as shown in Figure 7, it is not effective to increase the power generation from the PV system. Therefore, the power generated from FC system decreases due to less H2 generated. The self-sufficiency rate of FC system in Hamamatsu is high through the year, and it is over 100% even in winter for the 12 households’ case. Hamamatsu has long sunshine hours through the year

Figure 4. Monthly self-sufficiency rate of the FC system assumed to be installed in seven cities(20 households’ case).

Figure 5. Monthly self-sufficiency rate of the FC system assumed to be installed in seven cities (16 households’ case).

Figure 6. Monthly self-sufficiency rate of the FC system assumed to be installed in seven cities (12 households’ case).

Figure 7. Monthly mean temperature in seven cities.

Figure 8. Monthly mean wind velocity in seven cities.

Figure 9. Monthly sunshine hours in seven cities.

according to Figure 9. Furthermore, Hamamatsu has the highest monthly mean wind velocity through the year among seven cities. Strong wind prevents the temperature of the PV modules installed from increasing, thus the power generated by the PV system increases, according to Equations (1), (2), (3) and (4).

Figure 10 shows the annual self-sufficiency rate of FC system assumed to be installed in Nagoya, Toyota, Tajimi, Takayama, Ogaki, Hamamatsu and Shizuoka for 40, 20, 16 and 12 households’ cases. Though the monthly self-sufficiency rate varies, the surplus H2 obtained in the month whose monthly self-sufficiency rate is over 100% can be stored and provided for the month whose monthly self-sufficiency rate is below 100%. Therefore, the annual self-sufficiency rate of FC system is a good indicator to determine the optimum households’ number which can cover the electricity demand through the year.

According to Figure 10, the annual self-sufficiency rates of FC system for 16 and 12 households’ cases are over 100% irrespective of considered cities. Since it is better to provide the power to many households, this study has decided that 16 households’ (=4 stories) case is the optimum for the proposed BIPV + FC system. In addition, it is observed that the self-sufficiency rate of FC system for 20 households is over 100% in Hamamatsu. Therefore, Hamamatsu is the most appropriate city for installing the proposed BIPV + FC system among the seven cities studied.

The correlation between the households’ number and self-sufficiency rate of FC system per solar PV installation area for two cities in Aichi Prefecture, three cities in Gifu Prefecture and two cities in Shizuoka prefecture has been shown in Figures 11-13, respectively. In these figures, the regression formula of the approximate curves and R2 error are also shown.

Formula show the correlation between the households’ number and self-sufficiency rate of FC system per solar PV installation area can be expressed in the form of y = axb well. It might be thought that the self-sufficiency rate of

Figure 10. Annual self-sufficiency rate of FC system assumed to be installed in seven cities.

Figure 11. Relationship between the households’ number and self-sufficiency rate of FC system per solar PV installation area (Aichi prefecture).The correlation between the households’ number and self-sufficiency rate of FC system per solar PV installation area can be expressed in the form of y = axb well. R2 error is very small.

Figure 12. Relationship between the households’ number and self-sufficiency rate of FC system per solar PV installation area (Gifu prefecture). The correlation between the households’ number and self-sufficiency rate of FC system per solar PV installation area can be expressed in the form of y = axb well. R2 error is very small.

FC system per solar PV installation area will increase for the households’ number which is smaller than 12. However, this study assumed that the lowest limit of stories were set 3 which was the standard low height building. Therefore, this study hasn’t considered the case for households’ number which is smaller than 12.

4. Conclusions

This study has proposed an integrated BIPV + FC system for Japanese buildings.

Figure 13. Relationship between the households’ number and self-sufficiency rate of FC system per solar PV installation area (Shizuoka prefecture). The correlation between the households’ number and self-sufficiency rate of FC system per solar PV installation area can be expressed in the form of y = axb well. R2 error is very small.

The FC is fueled by H2 which is generated from the surplus power generated from BIPV through electrolytic process. The self-sufficiency rates of the FC have been investigated using meteorological data of two cities in Aichi prefecture (Nagoya, Toyota), three cities in Gifu prefecture (Tajimi, Takayama, Ogaki) and two cities in Shizuoka prefecture (Hamamatsu, Shizuoka) of Japan to understand the impact of local climate condition on the performance of the proposed system as well as to find out a universal system model. As a result, the following conclusions have been drawn from the study:

1) The annual self-sufficiency rates of FC system for 16 and 12 households’ cases are over 100% in all cities studied. Therefore, 16 households (= 4 stories) are thought to be the optimum households’ number for the proposed BIPV + FC system.

2) Hamamatsu is the most appropriate city for installing the proposed BIPV + FC system among the seven cities studied.

3) The correlation between the households’ number (x) and self-sufficiency rate of FC system per solar PV installation area (y) can be expressed in the form of y = axb well, where a and b depend on the locations/cities.

Cite this paper

Nishimura, A., Tanikaga, S., Hirota, M. and Hu, E. (2018) Energy Characteristics of an Integrated Power Generation System with Photovoltaic and Fuel Cell. Smart Grid and Renewable Energy, 9, 57-73. https://doi.org/10.4236/sgre.2018.94005

References

  1. 1. Agency for Natural Resources and Energy (2017) Energy White Paper 2017. http://www.enecho.meti.go.jp/about/whitepaper/2017pdf/whitepaper2017pdf_2_2.pdf

  2. 2. Jelle, B.P. (2016) Building Integrated Photovoltaics: A Concise Research Pathways. Energies, 9, 1-30.

  3. 3. Tripathy, M., Sadhu, P.K. and Panda, S.K. (2016) A Critical Review on Building Integrated Photovoltaic Products and Their Applications. Renewable and Sustainable Energy Reviews, 61, 451-465. https://doi.org/10.1016/j.rser.2016.04.008

  4. 4. Zomer, C., Nobre, A., Reindl, T. and Ruther, R. (2016) Shading Analysis for Rooftop BIPV Embedded in a High-Density Environment: A Case Study in Singapore. Energy and Buildings, 121, 159-164. https://doi.org/10.1016/j.enbuild.2016.04.010

  5. 5. Humada, A.M., Hojabri, M., Hamada, H.M. and Samsuri, F.B. (2016) Performance Evaluation of Two Technologies (c-Si and CIS) for Building Integrated Photovoltaic Based on Tropical Climate Condition: A Case Study in Malaysia. Energy and Buildings, 119, 233-241. https://doi.org/10.1016/j.enbuild.2016.03.052

  6. 6. Davi, G.A., Caamano-Martin, E., Ruther, R. and Solano, J. (2016) Energy Performance Evaluation of a Net Plus-energy Residential Building with Grid-Connected Photovoltaics System in Brazil. Energy and Buildings, 120, 19-29. https://doi.org/10.1016/j.enbuild.2016.03.058

  7. 7. Burg, B.R., Ruch, P., Paredes, S. and Michel, B. (2017) Effects of Radiative Forcing of Building Integrated Photovoltaic Systems in Different Urban Climates. Solar Energy, 147, 399-405. https://doi.org/10.1016/j.solener.2017.03.004

  8. 8. Lamnatou, C., baig, H., Chemisana, D. and Malick, T.K. (2017) Dielectric-Based 3D Building-Integrated Concentrating Photovoltaic Modules: An Environmental Life-Cycle Assessment. Energy and Buildings, 138, 514-525. https://doi.org/10.1016/j.enbuild.2016.12.038

  9. 9. Sagani, A., Mihelis, J. and Dedoussis, V. (2017) Techno-Economic Analysis and Life-Cycle Environmental Impacts of Small-Scale Building-Integrated PV Systems in Greece. Energy and Buildings, 139, 277-290. https://doi.org/10.1016/j.enbuild.2017.01.022

  10. 10. Davi, G.A., Asiain, J.L., Solano, J. and Caamano-Martin, E. (2017) Energy Refurbishment of an Office Building with Hybrid Photovoltaic System and Demand-Side Management. Energies, 10, 1117. https://doi.org/10.3390/en10081117

  11. 11. Uddin, K., Gough, R., Radcliffe, J., Marco, J. and Jennings, P. (2017) Techno-Economic Analysis of the Viability of Residential Photovoltaic Systems Using Lithium-Ion Batteries for Energy Storage in the United Kingdom. Applied Energy, 206, 12-21. https://doi.org/10.1016/j.apenergy.2017.08.170

  12. 12. Kumagaki, H. (2016) Renewable Energy Mass Transportation Based on Methanation Technology. Preprints of the 3rd Hydrogen Energy Lecture Meeting of the Japan Society Energy, Tokyo, 16 December 2016, 24.

  13. 13. Gonzalez, E.L., Llerena, F.I., Perez, M.S., Iglesias, F.R. and Macho, J.G. (2015) Energy Evaluation of a Solar Hydrogen Storage Facility: Comparison with Other Electrical Energy Storage Technologies. International Journal of Hydrogen Energy, 40, 5518-5525. https://doi.org/10.1016/j.ijhydene.2015.01.181

  14. 14. Marchenko, O.V. and Solomin, S.V. (2017) Modeling of Hydrogen and Electrical Energy Storage in Wind/PV Energy System on the Lake Baikal Coast. International Journal of Hydrogen Energy, 42, 9361-9370. https://doi.org/10.1016/j.ijhydene.2017.02.076

  15. 15. Barumann, L. and Boggasch, E. (2016) Experimental Assessment of Hydrogen Systems and Vanadium-Redox-Batteries for Increasing the Self-Consumption of Photovoltaic Energy in Buildings. International Journal of Hydrogen Energy, 41, 740-751. https://doi.org/10.1016/j.ijhydene.2015.11.109

  16. 16. Khalid, F., Dincer, I. and Rosen, M.A. (2016) Analysis and Assessment of an Integrated Hydrogen Energy System. International Journal of Hydrogen Energy, 41, 7960-7967. https://doi.org/10.1016/j.ijhydene.2015.12.221

  17. 17. Singh, A., Baredar, P. and Gupta, B. (2017) Techno-Economic Feasibility Analysis of Hydrogen Fuel Cell and Solar Photovoltaic Hybrid Renewable Energy System for Academic Research Building. Energy Conversion and Management, 145, 398-414. https://doi.org/10.1016/j.enconman.2017.05.014

  18. 18. Nishimura, A., Kitagawa, S., Hirota, M. and Kolhe, L.M. (2017) Energy Assessment of Building Integrated Photovoltaics and Fuel Cell Systems: Design Study for Buildings(s) of Mie, Japan. Smart Grid and Renewable Energy, 8, 129-144. https://doi.org/10.4236/sgre.2017.85009

  19. 19. Chubu Electric Power (2014) The Irradiance Data of the Project “PV300” (Electric Data Base).

  20. 20. The Society of Heating, Air-Conditioning and Sanitary of Engineering of Japan (1998) Assessment, Plan and Design of Co-Generation System by City Gas. Maruzen, Tokyo.

  21. 21. Nishimura, A., Ito, T., Kakita, M., Murata, J., Ando, T., Kamada, Y., Hirota, M. and Kolhe, M. (2014) Impact of Building Layout on Wind Turbine Power Output in the Built Environment: A Case Study of Tsu City. Journal of the Japan Institute of Energy, 84, 315-322. https://doi.org/10.3775/jie.93.315

  22. 22. Ministry of Internal Affairs and Communications (2017) Dwelling by Area of Floor Space (6 Groups) an Tenure of Dwelling (2 Groups)—Japan, 3 Major Metropolitan Areas, Prefectures and Major Cities (1998-2008). http://www.e-stat.go.jp/SGI/estat/ListE.do?bid=000001029530&code=0

  23. 23. Nishimura, A., Kitagawa, S., Hirota, M. and Hu, E. (2017) Assessment on Energy Self-Sufficiency Rate for Building Integrated Photovoltaics and Fuel Cell System in Japan. Smart Grid and Renewable Energy, 8, 195-211. https://doi.org/10.4236/sgre.2017.86013

  24. 24. New Energy and Industrial Technology Development Organization of Japan (2017) Guideline on Field Test Project of Photovoltaic Power Generation for Design, Construction and System. http://www.nedo.go.jp/content/100110086.pdf

  25. 25. Panasonic (2018) Products Lineup. http://sumai/panasonic.jp/solar/lineup.html

  26. 26. Panasonic (2018) Power Conditioner with High Conversion Efficiency. https://sumai.panasonic.jp/solar/need_power_conditioners.html

  27. 27. Kawamoto, K., Nakatani, S., Hagihara, R. and Nakai, T. (2002) High Efficiency HIT Solar Cell. Sanyo Technical Review, 34, 111-117.

  28. 28. Oozeki, T., Izawa, T., Otani, K., Tsuzuki, K., Koike, H. and Kurokawa, K. (2005) An Evaluation Method for PV Systems by Using Limited Data Item. IEEJ Transaction on Power Energy, 125, 1299-1307. https://doi.org/10.1541/ieejpes.125.1299

  29. 29. IHT (2018) Technical Information/Benefits of IHT’s Electrolysers. http://www.iht.ch/technologie/electrolysis/industry/technical-information-benefits-electrolysers.html

  30. 30. Kato, T. (2015) Possibility of Hydrogen Production from Renewable Energy. Journal of Japan Institute of Technology, 94, 7-18.

  31. 31. Panasonic (2018) Specification of ENEFARM. https://panasonic.biz/appliance/FC/house_07.html

  32. 32. Japan Meteorological Agency (2018) Past Meteorological Data Search. http://www.data.jma.go.jp/obd/stats/etrn/index.php